CHISEN SPF12V260-ST 12.8V 260Ah LiFePO4 akkumulyatori

QR kodi
CHISEN SPF12V260-ST: 12.8V 260Ah (3328Wh) LiFePO4 akkumulyatori, 4S + BMS, xuddi shu qo'rg'oshin-kislota / AGM / GEL akkumulyatoriga to'g'ridan-to'g'ri almashtirish. 80% DoD da ≥2000 sikl, 30.5kg, RV uy akkumulyatori, Dengiz quvvati va yoritish uchun.
Model SPF12V260-ST
产品详情

CHISEN SPF12V260-ST 12.8V 260Ah LiFePO4 akkumulyatori | Qo'rg'oshin-kislota o'rniga / Xizmat ko'rsatilmaydigan | Zavoddan to'g'ridan-to'g'ri OEM

CHISEN SPF12V260-ST haqida 30 soniyalik sharh

Model: SPF12V260-ST (12.8V 260Ah / 3328Wh, 4 ta LiFePO4 hujayrasi ketma-ket)

Texnologiya: LiFePO4 hujayralari + integrallashgan BMS (ortiqcha zaryad / chuqur razryad / ortiqcha tok / qisqa tutashuv / harorat himoyasi) + ABS korpus (IP65) + mis o'zakli klemmalar

Asosiy jihatlar: ≥2000 sikl @80% DoD (qo'rg'oshin-kislotadan 4-6×); 30.5kg akkumulyator, qo'rg'oshin-kislota og'irligining taxminan 40%; xizmat ko'rsatilmaydigan; 48V tizim uchun 4 tagacha ketma-ket

Odatiy qo'llanish: RV uy akkumulyatori, Dengiz quvvati va yoritish, Turar-joy off-grid quyoshi, Monitoring / CCTV zaxirasi

§1. Mahsulot ta'rifi va to'rt asosiy afzallik

CHISEN SPF12V260-ST — 12.8V 260Ah (3328Wh) LiFePO4 akkumulyatori bo'lib, 4 hujayrasi ketma-ket ulangan va integrallashgan BMSga ega; ekvivalent qo'rg'oshin-kislota / AGM / GEL akkumulyatori bilan bir xil o'rindiq o'lchami va klemma joylashuviga ega 8D korpus korpusga joylashtirilgan, shuning uchun akkumulyator uyasi, mahkamlagich va kabelni o'zgartirish talab etilmaydi.

ST seriyasi ham harakat, ham energiya saqlash rejimiga mos keladi — elektromobillar, energiya saqlash tizimlari, mudofaa va xavfsizlik, ochiq havodagi telekom, qayta tiklanuvchi energiya va boshqa og'ir sharoitlar. Saqlash uchun sig'imni zaxira vaqti va kunlik energiya bo'yicha tanlang; harakat rejimi uchun uzluksiz / cho'qqi tok va masofa bo'yicha.

Konfiguratsiya: 4S × 3.2V = 12.8V, 260Ah, 3328Wh; BMS hujayra kuchlanishini sezadi, passiv balanslash (balans nuqtasi 14.4V) hamda ortiqcha zaryad / chuqur razryad / ortiqcha tok / qisqa tutashuv / yuqori-past harorat himoyasini bajaradi va umumiy zaryad-razryad portiga ega.

Zaryad / razryad: tavsiya etilgan CC/CV: 14.6V (4×3.65V) va 52A (0.2C), maksimal 130A; maksimal uzluksiz razryad 150A (0.58C), cho'qqi 300A (3s), BMS uzilishi 10V (4×2.5V).

Qo'llanishlar: RV uy akkumulyatori, Dengiz quvvati va yoritish, Turar-joy off-grid quyoshi, Monitoring / CCTV zaxirasi, Off-grid mikro-tarmoq.

CHISEN 20+ yildan beri akkumulyatorlarga ixtisoslashgan, 60+ mamlakatga eksport qiladi va telekom, energetika, ma'lumotlar markazi, PV, RV/dengiz va tibbiy uskunalar sohalaridagi OEM/ODM mijozlarga hujayra, BMS va akkumulyator darajasidagi yechimlarni yetkazib beradi.

To'rt asosiy afzallik:

1. 2000 chuqur sikl, sikl soni bo'yicha qo'rg'oshin-kislotadan taxminan 4-6×: kuniga bitta 80% DoD siklida 2000 sikl 5+ yil loyihaviy xizmat muddatini beradi; xuddi shu rejimdagi qo'rg'oshin-kislota (50% DoD, 300-500 sikl) 1-1.5 yildan keyin to'liq almashtirishni talab qiladi. LiFePO4 chuqur razryadda sulfatlanmaydi, shuning uchun sig'im keskin tushmay, asta-sekin pasayadi.

2. Yengillik: har bir akkumulyator 30.5kg, xuddi shu qo'rg'oshin-kislota sig'imi uchun ~83.2kg, taxminan 63% yengilroq — tashish osonroq, qayiqda kamroq ballast, AGV va golf aravachalari uchun ko'proq foydali yuk.

3. Parvarishsiz, suv yo'q, kislota tumani yo'q: germetik xizmat ko'rsatilmaydigan konstruksiya: suv quyish, tenglashtiruvchi zaryad, kislota tumani va sulfatlanish yo'q; IP65 korpus, tor RV, seksiya va shkaf joylarida yon tomondan o'rnatishga (klemmalar oldinga) ruxsat beriladi.

4. Besh qavatli BMS himoyasi: 15.6V da ortiqcha zaryad uzilishi, 10V da chuqur razryad uzilishi, 450A ortiqcha tok va qisqa tutashuv himoyasi (250-500μs), 65℃ da yuqori harorat uzilishi va 0℃ dan pastda zaryadlash yo'q; BMS uzadi va avtomatik tiklanadi, bu shishish va issiqlik chiqishini oldini oladi.

Qo'shimcha: to'liq sikl samaradorligi ≥95% (odatiy), qo'rg'oshin-kislotada 70-85%; o'z-o'zidan razryad <3%/oy va to'liq zaryadda 6+ oy saqlash muddati, shuning uchun xuddi shu PV massivi va zaryadlovchi akkumulyatorga taxminan 10-20% ko'proq energiya beradi.

§2. Asosiy spetsifikatsiyalar

Ushbu model uchun tezkor ma'lumot (to'liq standartlar ro'yxati §4 da, seriya jadvali §6 da, zaryad va himoya chegaralari §12 va §15 da).

Parametr

Qiymat

Model

SPF12V260-ST

Seriya

ST standart turi

Nominal kuchlanish

12.8V

Nominal sig'im

260Ah (10 soatlik rejim)

Energiya

3328Wh

Hujayra konfiguratsiyasi

LiFePO4, 4 hujayra ketma-ket

Korpus / klemma uslubi

8D korpus

Maksimal uzluksiz razryad

150A (0.58C)

Cho'qqi razryad toki

300A (3s)

BMS razryad uzilish toki

450A ±20A (31ms)

Tavsiya etilgan zaryad kuchlanishi

14.6V (4×3.65V)

Ushlab turuvchi / kutish kuchlanishi

13.8V (4×3.45V)

BMS ortiqcha zaryad himoyasi

15.6V (4×3.9V)

Balanslash kuchlanishi

14.4V (4×3.6V)

Tavsiya etilgan zaryad toki

52A (0.2C)

Maksimal zaryad toki

130A (0.50C)

Razryad uzilish kuchlanishi

10V (4×2.5V)

Tavsiya etilgan past kuchlanish uzilishi

11V (4×2.75V)

Ichki qarshilik (1kHz, 50% SOC, 25℃)

≤8mΩ

O'lchamlar U×K×B

520×268×228 mm

Og'irlik

30.5kg (±2%)

Klemma

T11

Klemma momenti

9-11 N·m

Korpus materiali

ABS muhandislik plastigi

Korpus himoyasi

IP65

O'z-o'zidan razryad

<3% / oy (25℃)

Sikl xizmat muddati

≥2000 sikl @80% DoD (25℃)

Zaryad harorati

0 dan 45℃ gacha

Razryad harorati

−20 dan 60℃ gacha

Saqlash harorati

−5 dan 35℃ gacha

Sertifikatlash va hujjatlar

har bir jo'natma bilan CE muvofiqlik deklaratsiyasi (DoC) va UN38.3 sinov xulosasi beriladi; UL 1642 va IEC 62133-2 mijoz so'roviga ko'ra; MSDS va dengiz transporti identifikatsiya hisoboti kiritilgan

Yuk tashish tasnifi

UN 3480, Class 9

Izoh: yuqoridagi qiymatlar ushbu model ma'lumotnomasidan olingan; o'lchamlar U×K×B, klemmalar bilan birga, tolerantlik ±2mm.

§3. Model nomenklaturasi — maydonlar taqsimoti

CHISEN ST seriyasi segmentlangan koddan foydalanadi (seriya + kuchlanish sinfi + sig'im + tur + korpus), shuning uchun modelni faqat tizim kuchlanishi va mavjud joyga qarab tanlash mumkin.

Maydon

Ma'nosi

Bu model

SPF

Mahsulot seriyasi

SPF = LiFePO4 akkumulyator moduli

12.8V

Kuchlanish sinfi

12.8V = 4 hujayra × 3.2V

260

Nominal sig'im

10 soatlik rejimda 260Ah

-ST

Mahsulot turi

ST = Standard Type (shuningdek LT past haroratli, BL Bluetooth, LB past haroratli Bluetooth)

8D korpus

Korpus / klemma varianti

8D korpus

SPF12V260-ST = SPF seriyasi + 12.8V sinf (4S) + 260Ah + ST standart turi, 8D korpus.

§4. Amaldagi xalqaro / mintaqaviy / Xitoy standartlari

Quyidagi standartlar loyihalash, xarid va tender hujjatlari uchun havola qilinadi.

Standart

Sarlavha

Type

Qabul qilinishi

Use

IEC 62619:2022

Ishqoriy yoki boshqa kislota bo'lmagan elektrolitli ikkilamchi elementlar va batareyalar — sanoat qo'llanishlari uchun ikkilamchi litiy elementlari va batareyalariga xavfsizlik talablari

Xalqaro

Xavfsizlik loyihalash asosi

Eksport / sanoat ESS

IEC 62133-2:2017

Germetik ikkilamchi elementlar va batareyalar — portativ litiy tizimlariga xavfsizlik talablari

Xalqaro

Hujayra va akkumulyator xavfsizligi

Eksport / mijoz qabuli

UN38.3

BMT sinovlar va mezonlar qo'llanmasi, 38.3 bo'lim — transport xavfsizligi sinovlari

Xalqaro

Transport sinovlari

Havo / dengiz / kuryer

UL 1642

Xavfsizlik standarti — litiy batareyalar (hujayralar)

USA

Hujayra xavfsizligi

Shimoliy Amerika

GB 31241-2022

Portativ elektron uskunalar uchun litiy-ion elementlari va batareyalari — xavfsizlik bo'yicha texnik spetsifikatsiya

Xitoy

Loyihaviy ma'lumot

Mahalliy sotuv / tenderlar

GB 40165-2021

Statsionar elektron uskunalar uchun litiy-ion elementlari va batareyalari — xavfsizlik bo'yicha texnik spetsifikatsiya

Xitoy

Loyihaviy ma'lumot

Mahalliy ESS / tenderlar

UN 3480 Class 9

BMT namunaviy qoidalari — litiy-ion batareyalari (yakka holda)

Xalqaro

Transport tasnifi

Bronlash / bojxona

Izoh: uchinchi tomon sinov hisobotlari va manzil mamlakat ruxsatnomalari (masalan, Yevropa Ittifoqi batareyalar reglamenti, UL 2054 akkumulyator sertifikati) loyiha bo'yicha hal qilinadi; standartlar loyihalash va xarid uchun ma'lumot sifatida keltirilgan.

§5. Fizik tuzilma va materiallar (LiFePO4 hujayralari + BMS)

CHISEN SPF12V260-ST tuzilishi:

Hujayralar: prizmatik alyuminiy korpusli yoki silindrik po'lat korpusli LiFePO4 hujayralari; olivin LiFePO4 katodi tuzilmaviy barqaror va kislorod ajratmaydi, bu xavfsizlik zaxirasining asosidir.

Anod va elektrolit: grafit anod, LiPF6 organik elektrolit va polietilen (PE) separator; hujayralar sig'im, kuchlanish va ichki qarshilik bo'yicha saralanadi, guruh ichida 20mV ichida moslashtiriladi.

BMS: ortiqcha zaryad, chuqur razryad, ortiqcha tok, qisqa tutashuv, yuqori/past harorat himoyasi va passiv balanslash, umumiy port; hujayra sezish ±25mV, balanslash 14.4V da boshlanadi va 20mV ichida yopiladi.

besh qavatli himoya chegaralari (ketma-ket 4 hujayra uchun):

Himoya

Sabab

Tiklanish

Ta'sir vaqti

Ortiqcha zaryad

hujayra ≥3.9V (akkumulyator 15.6V)

3.6V/hujayra (14.4V) ga qaytganda avtomatik tiklanadi

instant

Chuqur razryad

hujayra ≤2.5V (akkumulyator 10V)

2.8V/hujayra dan yuqori zaryaddan keyin tiklanadi

instant

Ortiqcha tok

≥450A ±20A

yuk olingach avtomatik tiklanadi

31ms

Qisqa tutashuv

chiqish qisqa tutashgan

nosozlik bartaraf etilgach avtomatik tiklanadi

250-500μs

Yuqori harorat

≥65℃

55℃ dan pastda tiklanadi

instant

Past harorat

zaryadlash ≤0℃

5℃ dan yuqorida tiklanadi

instant

Korpus va zichlash: ABS muhandislik plastigi, 8D korpus, IP65; korpus va qopqoq o'rtasidagi ikki qavatli zichlash (konstruktiv yelim + qistirma) va klemmadagi O-ring namlikni ichkariga o'tkazmaydi.

Belgilash: model va sig'im old tomonga silkografiya yoki lazer bilan belgilanadi: model, kuchlanish, sig'im, energiya, ishlab chiqarish partiyasi va ogohlantirish belgilari.

Qo'rg'oshin-kislotadan tuzilmaviy farq: qo'rg'oshin-kislota (AGM / GEL) 50% DoD da 80% sig'imgacha 300-500 sikl beradi va baribir tenglashtiruvchi zaryad hamda klemma tekshiruvini talab qiladi; LiFePO4 esa 80% DoD da 2000+ sikl beradi va parvarish talab qilmaydi. Xuddi shu hajmda foydali energiya taxminan 1.6× (80% va 50% DoD), bu qo'rg'oshin-kislotani almashtirishning bevosita qiymatidir.

Almashtirish ogohlantirishi: qo'rg'oshin-kislota zaryadlovchisi 13.6-13.8V da ushlab turadi va 14.4V da tenglashtiradi, bu model esa 14.6V o'zgarmas kuchlanishni talab qiladi. Qo'rg'oshin-kislota zaryadlovchisini qoldirish akkumulyatorni doimiy kam zaryadda qoldiradi, bu sig'imni pasaytiradi va balanslashni buzadi — zaryadlovchini litiy rejimiga o'tkazing yoki almashtiring (§12 ga qarang).

§6. ST seriyasi 12.8V to'liq sig'im jadvali (20 model)

ST seriyasining 12.8V platformasida 20 ta sig'im modeli bor (LiFePO4, 4S). Bir xil kuchlanish sinfidagi modellar sig'im bo'yicha to'g'ridan-to'g'ri almashtiriladi va yuqori tizim kuchlanishi uchun ketma-ket ulanadi.

No.

Model

V

Ah

Maks A

O'lcham mm

kg

Klemma

Korpus / BCI

1

SPF12V7.2-ST

12.8

7.2

15

151×65×102

0.9

F2

F2 kichik korpus

2

SPF12V9-ST

12.8

9

15

151×65×102

1.1

F2

F2 kichik korpus

3

SPF12V10-ST

12.8

10

15

151×98×105

1.3

F2

F2 kichik korpus

4

SPF12V12-ST

12.8

12

15

151×98×105

1.65

F2

F2 kichik korpus

5

SPF12V20-ST

12.8

20

20

181×76×168

2.6

NB1

NB1 korpus

6

SPF12V35-ST

12.8

35

35

195×131×171

4.4

T11

U1 korpus

7

SPF12V40-ST

12.8

40

40

198×166×171

5.4

T11

166 standart korpus

8

SPF12V50-ST

12.8

50

50

198×166×171

6.3

T11

166 standart korpus

9

SPF12V75-ST

12.8

75

75

260×168×221

9.6

T11

24 guruh korpusi

10

SPF12V80-ST

12.8

80

80

307×168×221

10.4

T11

27 guruh korpusi

11

SPF12V100-ST-G27

12.8

100

100

307×168×221

12.2

T11

BCI 27 guruhi

12

SPF12V100-ST-G31

12.8

100

100

329×172×223

12.6

T11

BCI 31 guruhi

13

SPF12V100-DST-S

12.8

100

100

318×175×190

12.6

DIN

DIN qisqa korpus (94R / H7L4 BCI)

14

SPF12V100-DST

12.8

100

100

355×175×190

12.8

DIN

DIN uzun korpus (49 / H8L5 BCI)

15

SPF12V125-ST

12.8

125

150

329×172×223

14

T11

31 guruh korpusi

16

SPF12V150-ST

12.8

150

150

520×268×228

21

T11

8D korpus

17

SPF12V200-ST

12.8

200

150

484×170×241

25.2

T11

kompakt korpus

18

SPF12V200-ST-8D

12.8

200

150

520×268×228

24.5

T11

8D korpus

19

SPF12V260-ST

12.8

260

150

520×268×228

30.5

T11

8D korpus

20

SPF12V300-ST

12.8

300

150

520×268×228

33.5

T11

8D korpus

Bu sahifa yuqorida ajratilgan SPF12V260-ST ni qamrab oladi: 260Ah / 3328Wh / 30.5kg.

Xuddi shu seriyadagi boshqa kuchlanish sinflari:

Class

Seriya

Modellar

Sig'im diapazoni

Maksimal razryad

Odatiy qo'llanish

12V

4S

20

7.2-300Ah

15-150A

RV, dengiz, off-grid quyosh, telekom/CCTV, harakatlanish va pol yuvish mashinalari

24V

8S

9

10-140Ah

15-140A

AGV, nogironlar aravachalari, dengiz, RV, quyosh ko'cha chiroqlari

36V

12S

6

7-96Ah

10-100A

Golf aravachalari, uch g'ildiraklilar, pol yuvish mashinalari, shtablerlar, bog' texnikasi

48V

16S

5

12-72Ah

20-72A

Telekom obyektlari, uy ESS, golf aravachalari, forkliftlar, edge ma'lumotlar markazlari

Izoh: bir zanjirda turli sig'im yoki partiyalarni aralashtirmang — zanjirdagi har bir blok bir xil model, sig'im va partiyada bo'lishi shart (§18b ga qarang).

§7. Asosiy qo'llanishlar va namunali holatlar

CHISEN SPF12V260-ST quyidagi 5 ta qo'llanishga xizmat qiladi (bu model: 260Ah / 3328Wh, taxminan 2662Wh foydali, 80% DoD da):

RV uy akkumulyatori: Xuddi shu o'rindiq o'lchamidagi qo'rg'oshin-kislota uy akkumulyatorini almashtiradi, 80% DoD foydali.

Dengiz quvvati va yoritish: Ishga tushirish va uy ehtiyoji; chuqur razryaddan keyin ham aylantiradi.

Turar-joy off-grid quyoshi: Uylar uchun kunduzgi PV zaryad va tungi razryad.

Monitoring / CCTV zaxirasi: kichik obyektlar, kameralar va kirish nazorati uchun 12V zaxira; shkafga sig'adigan darajada kompakt.

Off-grid mikro-tarmoq: Kichik orol, chorvachilik va chekka obyekt tizimlari.

Quyidagi har bir raqam ushbu modelning o'z sig'imidan hisoblangan (DoD 0.8, invertor 0.9):

Korpus 1: Yoritish / monitoring (bu modeldan hisoblangan)

260Ah (3328Wh) DoD 0.8 va invertor samaradorligi 0.9 da 400W yukni taxminan 6 soat ishlatadi; 200W da ishlash vaqti ikki barobar oshib, taxminan 12 soatga yetadi.

Korpus 2: Monitoring / telekom zaxirasi (bu modeldan hisoblangan)

4 soatlik zaxira uchun xuddi shu akkumulyator 600W ni ta'minlaydi (3328Wh × 0.8 × 0.9 ÷ 4).

Korpus 3: Kunlik sikl (bu modeldan hisoblangan)

kuniga bitta 80% DoD sikli kuniga 2662Wh, yiliga taxminan 971630Wh beradi; 2000 sikl taxminan 5 yil.

Korpus 4: Qo'rg'oshin-kislota o'rniga (bu modeldan hisoblangan)

xuddi shu qo'rg'oshin-kislota sig'imi taxminan 1664Wh foydali (50% DoD) beradi, bu yerda esa 2662Wh (80% DoD), 60% ko'proq energiya, 30.5kg va taxminan 83.2kg — taxminan 63% yengilroq.

Korpus 5: Zanjirni kengaytirish (bu modeldan hisoblangan)

4 ta ketma-ket ulash 51.2Ah da 13312V / 260Wh akkumulyator beradi; 4 tagacha parallel zanjir, maksimum 1040Ah / 53248Wh.

§8. ST seriyasi va qo'rg'oshin-kislota / AGM / GEL — to'liq taqqoslash

Bir xil o'rindiq o'lchami va nominal kuchlanish, LiFePO4 va qo'rg'oshin-kislota (AGM / GEL):

Item

Bu seriya (LiFePO4 ST)

Qo'rg'oshin-kislota AGM / GEL

Xulosa

Energiya zichligi

~109 Wh/kg

~30-40 Wh/kg

har kg uchun 2-3× energiya

Sikl xizmat muddati

≥2000 @80% DoD

300-500 @50% DoD

qo'rg'oshin-kislotadan 4-6×

Foydali sig'im

80-90% DoD

50% DoD (chuqurroq sikllar xizmat muddatini qisqartiradi)

60% ko'proq foydali energiya

To'liq sikl samaradorligi

≥95%

70-85%

xuddi shu PV massividan 10-20% ko'proq

O'z-o'zidan razryad

<3% / oy

3-5% / oy, qo'shimcha sulfatlanish

6+ oy saqlash muddati

Og'irlik

30.5kg

~83.2kg

taxminan 63% yengilroq

Parvarish

none

suv quyish, tenglashtiruvchi zaryad, korroziya tekshiruvlari

deyarli nol texnik xizmat

Uzluksiz rejim

0.58C (cho'qqi 1.2C)

0.2-0.3C

ishga tushirishda kuchlanish tushmaydi

Past haroratda razryad

−20℃ da ~65% (odatiy)

−20℃ da ~50%

sovuq omborlar va qish uchun yaxshiroq

O'rnatish

teskaridan tashqari har qanday holat

faqat tik

shkaflar va seksiyalarga sig'adi

Muhit

qo'rg'oshin-kislota elektroliti yo'q, to'liq qayta ishlanadi

qo'rg'oshin va sulfat kislota, utilizatsiya talablari yuqoriroq

soddaroq qayta ishlash

10 yilda almashtirishlar

1-2

4-6

ega bo'lishning umumiy xarajati pastroq

§9. Tanlov qarorlari jadvali

Bu modelning (260Ah / 12.8V) har bir qo'llanishga mosligi; "birgalikda mos" bir necha blokni ketma-ket yoki parallel ulash zarurligini bildiradi.

Qo'llanish

Bu modelga moslik

Note

Monitoring / yoritish / kirish nazorati

Mos

260Ah yetarli

RV / kemper uy quvvati

Mos

75Ah va yuqori tavsiya etiladi; bu model 260Ah

Dengiz quvvati / uy ehtiyojlari

Mos

ishga tushirish uchun ≥1C; 100Ah va yuqori

Turar-joy off-grid quyoshi

Mos

tungi iste'mol ÷ 0.8 DoD dan hisoblang

Telekom / CCTV zaxirasi

Mos

4-10 soat zaxira

Telekom obyekti 48V

Birgalikda mos

48V da to'g'ridan-to'g'ri; boshqa sinflarni zanjirlang

Golf aravachasi / elektro-uch g'ildirakli

Birgalikda mos

36V / 48V da to'g'ridan-to'g'ri; 12V dan 3-4 ta ketma-ket

AGV / forklift

Birgalikda mos

24V / 48V da to'g'ridan-to'g'ri; boshqa sinflarni zanjirlang

§10. Sig'im hisoblash formulasi va konfiguratsiya misollari

Sig'im (Ah) = yuk (W) × zaxira vaqti (h) ÷ tizim kuchlanishi (V) ÷ invertor samaradorligi ÷ razryad chuqurligi ÷ harorat koeffitsienti

Taxminlar: invertor samaradorligi 0.85 (past chastotali) / 0.90 (yuqori chastotali) / 1.0 (DC yuklar).

DoD va harorat: LiFePO4 0.80-0.90 ga ruxsat beradi (qo'rg'oshin-kislota faqat 0.50); harorat koeffitsienti 25℃ da 1.0, 0℃ da 0.90, −10℃ da 0.75, −20℃ da 0.65, 45℃ da 0.95; 20-30% qarish zaxirasini qoldiring.

Hisoblash 1-misol (12.8V tizim): off-grid yoritish yuki kuniga 8 soat 400W, invertor 0.9, DoD 0.8 → 400×8÷12.8÷0.9÷0.8 ≈ 347.2Ah — 260Ah × 2 parallel tanlang (jami 520Ah).

Pack 2-misol (4 ta ketma-ket = 51.2V / 13312Wh akkumulyator): DoD 0.8 va invertor 0.9 da 2400W ni taxminan 4.0 soat ushlab turadi (13312×0.8×0.9÷2400); 1200W da ishlash vaqti ikki barobar oshib, taxminan 8.0 soatga yetadi.

o'zgarmas tok bilan razryad qobiliyati (25℃, odatiy, harorat va yukka qarab o'zgaradi):

Razryad vaqti

Tok

Foydali sig'im

12.8V dagi quvvat

20 HR

13.0 A

260 Ah

~166 W

10 HR

26.0 A

260 Ah

~333 W

5 HR

52.0 A

260 Ah

~666 W

3 HR

86.7 A

255 Ah

~1087 W

1 HR

260.0 A

247 Ah

~3162 W

Amaliy qoida: qisqa yuqori tokli ish (UPS 30 daqiqa sinfi) yuqori tok modelini talab qiladi, §15 dagi tok jadvali bilan tekshiriladi; uzoq past tokli ish (telekom 4-10 soat) 10HR qatoridan foydalanadi.

zaryadlovchi mosligi — qo'rg'oshin-kislota almashtirishlarida eng ko'p xato bo'ladigan joy:

Zaryadlovchi turi

To'g'ridan-to'g'ri ishlatsa bo'ladimi?

Sozlama

Litiy zaryadlovchi

To'g'ridan-to'g'ri ishlatiladi

14.6V o'zgarmas kuchlanish, tok ≤52A (0.2C)

Mavjud qo'rg'oshin-kislota zaryadlovchisi

To'g'ridan-to'g'ri emas

Litiy rejimiga (14.6V CV) o'tkazing yoki almashtiring; harorat kompensatsiyasi o'chirilgan bo'lishi shart

MPPT quyosh kontrolleri

Litiy rejimini qo'llab-quvvatlashi shart

Absorbsiya 14.6V, ushlab turuvchi 13.8V; qo'rg'oshin-kislota tenglashtirishini va harorat kompensatsiyasini o'chiring

Avtomobil DC-DC / generator

Kuchlanishni cheklash shart

Chiqish 15.6V dan oshmasligi kerak, aks holda BMS ortiqcha zaryad himoyasi ishga tushadi

Invertor-zaryadlovchi

Foydali

LiFePO4 / 4S rejimini tanlang, zaryad toki 0.2C

§11. Sikl xizmat muddati va ega bo'lishning umumiy xarajati (TCO)

Sikl xizmat muddati ≥2000 sikl @80% DoD (25℃); 1C zaryad/razryadda 2000 sikldan keyin ham hujayralar sig'imi 80% dan yuqori bo'lib qoladi, odatdagi 0.2C da sikl qilingan akkumulyator esa odatda bu ko'rsatkichdan oshadi.

TCO = xarid xarajati + almashtirishlar × xarid xarajati + parvarish + to'xtash zarari − qoldiq qiymat

Item

LiFePO4 (bu seriya)

Qo'rg'oshin-kislota AGM / GEL

Sikl xizmat muddati

2000 @80% DoD

350 @50% DoD

10 yillik sikllar (kuniga bitta)

3650

3650

10 yil davomida zarur akkumulyatorlar

2

11

Xarid xarajati indeksi (misol)

1.0

har bir akkumulyator uchun 0.45

10 yillik xarid indeksi

2.0

4.9

Parvarish

none

suv quyish, tenglashtirish, korroziya tekshiruvlari

To'xtash vaqtidagi almashtirishlar

1

10

Bir sikl narxi

low

high

Izoh: xarajat indeksi faqat almashtirishlar soni farqini ko'rsatish uchun ishlatilgan namunaviy taxmin; haqiqiy loyiha narxi uchun taklif so'rang.

§12. Zaryad kuchlanishini sozlash va harorat bog'liqligi

Standart zaryad 14.6V (4×3.65V) CC/CV, 52A (0.2C), maksimal 130A; ushlab turuvchi / kutish rejimi 13.8V (4×3.45V).

Bosqich

Kuchlanish (25℃)

Tok

Uzilish

O'zgarmas tok (CC)

14.6V gacha ko'taring

52A (0.2C)

14.6V ga yetadi

O'zgarmas kuchlanish (CV)

14.6V

tapering

tok 0.05C (~13.0A) ga tushadi

Ushlab turuvchi / kutish

13.8V

≤0.02C

continuous

Balanslash

14.4V

passive

hujayra deltasi <20mV

Harorat bo'yicha zaryadlash strategiyasi:

Harorat

Ruxsat etilgan tok

Zaryad kuchlanishi

Note

< 0℃

zaryadlash taqiqlangan

—

BMS zaryad yo'lini bloklaydi; sovuq omborlar va qishki obyektlar isitish yoki LT versiyani talab qiladi

0-10℃

0.1C chegara

14.6V

past haroratda zaryad qabul qilish pasayadi

10-25℃

0.2C

14.6V

optimal oraliq

25-40℃

0.2-0.3C

14.6V

shamollatishni ta'minlang

40-45℃

0.1C pasaytirilgan

14.6V

45℃ dan yuqorida zaryadlash yo'q

> 45℃

zaryadlash taqiqlangan

—

BMS yuqori harorat himoyasi

LiFePO4 qo'rg'oshin-kislota uchun (-3mV/℃/hujayra) harorat kompensatsiyasini talab qilmaydi; hujayra chegaralarini BMS boshqaradi, shuning uchun zaryadlovchi faqat CV nuqtasini aniq ushlab turishi kerak.

Almashtirish nuqtasi: bu qo'rg'oshin-kislota almashtirishlarida eng ko'p xato qilinadigan bosqich. Qo'rg'oshin-kislota zaryadlovchisi 13.6-13.8V da ushlab turadi va 14.4V da tenglashtiradi, ikkalasi ham bu model talabidan past, shuning uchun akkumulyator doimiy kam zaryadda qoladi, hujayralar uzoqlashadi va sig'im tez pasayadi. Zaryadlovchini 14.6V CV ga va 0.2C tok chegarasiga sozlang yoki litiy zaryadlovchiga almashtiring; harorat kompensatsiyasini o'chiring.

§13. Ishlash harorati diapazoni (razryad / zaryad / saqlash)

Razryad −20 dan 60℃ gacha, zaryad 0 dan 45℃ gacha, saqlash −5 dan 35℃ gacha; optimal 25℃ (sig'im uchun tayanch nuqta). BMS 65℃ da uzadi va 55℃ da tiklanadi.

Harorat

Foydali sig'im (odatiy)

Zaryadlash

Note

60℃ (razryad chegarasi)

~95%

prohibited

pasaytirilgan quvvat; majburiy shamollatish talab etiladi

40℃

~100%

0.1C pasaytirilgan

to'g'ridan-to'g'ri quyosh nuridan saqlaning, sovutishni yaxshilang

25℃ (tayanch)

100%

0.2C

sig'im va xizmat muddatining eng yaxshi balansi

0℃

~90%

0.1C chegara

zaryadni qabul qilish pastroq

−10℃

~75%

prohibited

zaryadlashdan oldin 0℃ dan yuqori haroratgacha qizdiring

−20℃ (razryad chegarasi)

~65%

prohibited

faqat razryad, BMS past harorat himoyasi

Izoh: sig'im tok va haroratga qarab o'zgaradi; ko'rsatkichlar 0.2C uchun odatiy. −20℃ da LiFePO4 taxminan 65% beradi, qo'rg'oshin-kislota esa taxminan 50% — bu sovuq omborlar va baland tog'li loyihalar uchun muhim.

issiqlik qarishni tezlashtiradi: 25℃ dan yuqorida har 10℃ ko'tarilish sikl xizmat muddatini taxminan ikki barobar qisqartiradi, shuning uchun 45℃ dan yuqori uzluksiz ish uchun shamollatishni yaxshilang, zaryad kuchlanishining yuqori chegarasini pasaytiring yoki yuqori haroratga moslashtirilgan variantni tanlang.

§14. O'z-o'zidan razryad darajasi va saqlash shartlari

To'liq zaryaddan 25℃ da o'z-o'zidan razryad oyiga 3% dan past, shuning uchun to'liq zaryadlangan akkumulyator 6 oydan keyin ham ishga tushadi; uzoq saqlash uchun 30-50% SOC da saqlang va har 3 oyda to'ldiring.

Saqlash harorati

O'z-o'zidan razryad

Qayta zaryadlash oralig'i

Qoldiq sig'im

20℃

<1.5% / oy

12 oy

~90%

25℃

<3% / oy

6 oy

~85%

35℃

<4% / oy

3 oy

~80%

45℃

<6% / oy

1-2 oy

~70%

Quruq, shamollatiladigan joyda, quyosh nuri, erituvchilar va korroziv gazlardan uzoqda −5 dan 35℃ gacha saqlang; klemmalarni izolyatsiya qiling, metall qismlar bilan bo'sh saqlamang; uzoq saqlashdan oldin 30-50% SOC gacha razryad qiling va har 3 oyda to'ldiring. 12 oydan ortiq saqlangan akkumulyatorlar ishga tushirishdan oldin to'liq zaryad/razryad va sig'im tekshiruvini talab qiladi.

§15. Maksimal zaryad toki va razryad uzilish kuchlanishi

Tavsiya etilgan zaryad 52A (0.2C), maksimal 130A (0.50C); maksimal uzluksiz razryad 150A (0.58C), cho'qqi 300A (3s), BMS ortiqcha tok va qisqa tutashuv himoyasi 450A ±20A (31ms).

Razryad toki

Uzilish kuchlanishi

Odatiy qo'llanish

≤ 0.1C (≤ 26.0A)

10V

uzoq muddatli kutish rejimi, monitoring

0.1-0.5C (26.0-130.0A)

10V

oddiy sikl

0.5-1.0C (130.0-260.0A)

10V

tortish, ishga tushirish, invertor cho'qqilari

1.0-2.0C (260.0-520.0A)

10V

qisqa cho'qqilar (≤3s), BMS cheklaydi

> 2.0C (> 520.0A)

—

taqiqlangan; BMS ortiqcha tok himoyasi ishga tushadi

Qisqa tutashuv himoyasi: BMS 250-500μs ichida uziladi; 1kHz AC ichki qarshiligi 8mΩ dan kutilayotgan qisqa tutashuv toki taxminan 1600A (12.8V÷8mΩ), faqat saqlagich va kabel tanlash uchun keltirilgan, sinov qiymati emas.

Zaryad tugashi: CV toki 0.05C (taxminan 13.0A) dan pastga tushganda akkumulyator to'lgan hisoblanadi; uzilgandan keyin BMS kuzatishni davom ettiradi va hujayra 3.6V/hujayra dan pastga tushganda zaryadni qayta boshlaydi.

§16. OEM/ODM bir joydan moslashtirish

CHISEN SPF12V260-ST standart elektr ko'rsatkichlarini o'zgartirmasdan bir joydan OEM/ODMni qo'llab-quvvatlaydi:

Korpus rangi: mijoz Pantone bo'yicha ABS korpus (standart kulrang-oq, qo'shimcha qizil / ko'k / yashil / sariq / to'q sariq yoki istalgan rang).

Bosma va belgilash: mijoz logotipi silkografiya (istalgan tilda), model / seriya / ishlab chiqarilgan sana / mijoz kodi / shtrix-kod lazer bilan belgilanadi.

Qadoqlash: standart rangli quti va neytral karton; logotip, rang, shtrix-kod va xavfsizlik yorlig'i buyurtma bo'yicha.

Yorliq: akkumulyator yorlig'i mijoz talabiga muvofiq, ko'p tilli va ko'p qoidalar bo'yicha tuzilgan.

Klemma: standart T11; boshqa klemma shakllari loyiha bo'yicha tayyorlanishi mumkin.

BMS variantlari: ixtiyoriy RS485 / CAN, Bluetooth ilova monitoringi, past haroratli isitish plyonkasi, ikkilamchi chiqish.

Sertifikatlash va hujjatlar: har bir jo'natma bilan CE muvofiqlik deklaratsiyasi (DoC), UN38.3 sinov xulosasi, MSDS va dengiz transporti identifikatsiyasi beriladi; UL 1642 va IEC 62133-2 mijoz so'roviga ko'ra; loyiha bo'yicha uchinchi tomon tekshiruvi.

MOQ va yetkazib berish muddati: namunalar 1 blokdan; ombordagi modellar 7-15 kun, buyurtma asosida 30-45 kun; konteyner MOQ model va qadoqlashga bog'liq.

individual taklif va narx uchun model, miqdor, manzil bozori va sertifikatlash talablari bilan sales@chisen.cn manziliga yozing; bir ish kuni ichida javob beramiz.

§17. Ko'p so'raladigan savollar — muhandislik savollari

Sanoat obyektlari muhandislari eng ko'p beradigan 18 savol: parametrlar, tanlov, o'rnatish, zaryadlash uskunalari, yuk tashish va sotuvdan keyingi xizmat.

1. SPF12V260-ST uchun zaryad kuchlanishi va toki qanday?

14.6V (4×3.65V), tavsiya etilgan 52A (0.2C) va maksimal 130A; ushlab turuvchi / kutish rejimi 13.8V (4×3.45V); BMS ortiqcha zaryad uzilishi 15.6V.

2. Sikl xizmat muddati qanday?

25℃ da ≥2000 sikl @80% DoD; kuniga bitta chuqur sikl 5+ yil loyihaviy xizmat muddatini beradi, sayozroq sikl (50% DoD) esa 2000 sikldan ancha oshadi.

3. Qo'rg'oshin-kislotani to'g'ridan-to'g'ri almashtira oladimi?

Ha. O'rindiq o'lchami, klemma joylashuvi va nominal kuchlanish mos keladi, shuning uchun uya va kabel o'z holicha qoladi; ammo qo'rg'oshin-kislota zaryadlovchisi 14.6V o'zgarmas kuchlanishga va 0.2C chegarasiga sozlanishi kerak, aks holda doimiy kam zaryad akkumulyatorni tezda eskitadi (§12 ga qarang).

4. Ketma-ket yoki parallel ulash mumkinmi?

ma'lumotnoma 4 tagacha ketma-ket ulashga ruxsat beradi (12.8V→51.2V); parallel 4 blokgacha, avval parallel, keyin ketma-ket. Ulashdan oldin hujayralar deltasi <50mV va ichki qarshilik farqi <15% bo'lishi, barcha bloklar bir xil model, sig'im va partiyada bo'lishi shart.

5. 0℃ dan pastda zaryadlash mumkinmi?

Yo'q — BMS 0℃ dan pastda zaryadlashni bloklaydi (razryad esa mumkin, −20℃ da sig'imning taxminan 65%). Sovuq omborlar va qishki obyektlar uchun LT past haroratli versiyani tanlang yoki isitish plyonkasini qo'shing.

6. Ichki qarshilik va qisqa tutashuv toki qanday?

Ichki qarshilik ≤8mΩ (1kHz, 50% SOC, 25℃); shu qarshilikdan hisoblangan kutilayotgan qisqa tutashuv toki taxminan 1600A bo'lib, faqat saqlagich tanlash uchun keltirilgan, sinov qiymati emas.

7. Klemma, o'lchamlar va og'irlik qanday?

T11, moment 9-11 N·m; 520×268×228 mm; 30.5kg.

8. Ish harorati va o'z-o'zidan razryad qanday?

Razryad −20 dan 60℃ gacha, zaryad 0 dan 45℃ gacha, saqlash −5 dan 35℃ gacha; 25℃ da o'z-o'zidan razryad <3%/oy va to'liq zaryaddan 6 oy saqlash muddati.

9. U qaysi standartlarga javob beradi?

IEC 62619:2022, IEC 62133-2, UN38.3 va UL 1642 (hujayralar), GB 31241-2022 va GB 40165-2021 ga asoslanib loyihalangan. Har bir jo'natma bilan CE muvofiqlik deklaratsiyasi (DoC) va UN38.3 sinov xulosasi beriladi; UL 1642 va IEC 62133-2 so'rov bo'yicha tashkil etiladi; jo'natma UN 3480 Class 9 bo'yicha amalga oshiriladi.

10. Yon tomondan yoki teskari o'rnatish mumkinmi?

Tik yoki yon tomondan (klemmalar oldinga) o'rnatiladi, maksimal 90° og'ish; hech qachon teskari emas — zichlagich va ichki hujayra guruhi bunga yo'l qo'ymaydi.

11. Eksport uchun qanday hujjatlar kerak?

Qadoqlash varaqasi, tijorat hisob-fakturasi, CO, MSDS, UN38.3 sinov xulosasi va dengiz transporti identifikatsiya hisoboti (UN3480, Class 9 xavfli yuk, IMDG Kodeksiga muvofiq; qadoqlash guruhi xavfli yuk sertifikatida ko'rsatilganidek); so'rov bo'yicha uchinchi tomon tekshiruvi va manzil mamlakat ruxsatnomalari.

12. MOQ va yetkazib berish muddati qanday?

Namunalar 1 blokdan; ombordagi modellar 7-15 kun, OEM moslashtirish 30-45 kun; konteyner MOQ model va qadoqlashga bog'liq.

13. Kafolat qanday?

jo'natilgandan boshlab 24 oy yoki 2000 sikl @80% DoD / ≥80% sig'im saqlanishi, qaysi biri avval bo'lsa; uzaytirilgan shartlar kelishiladi va tenderlar uchun kafolat xatlari berilishi mumkin.

14. Narx va yuk tashish qanday hisoblanadi?

EXW zavod narxi; dengiz yuk tashish manzil portigacha (FOB / CIF / DDP) hisoblanadi. Miqdori, manzil porti va sertifikatlash talablari bilan sales@chisen.cn manziliga elektron xat yuboring.

15. Uni to'g'ridan-to'g'ri quyosh kontrolleridan zaryadlash mumkinmi?

MPPT kontroller litiy rejimini qo'llab-quvvatlashi shart: absorbsiya 14.6V, ushlab turuvchi 13.8V, qo'rg'oshin-kislota tenglashtirishi va harorat kompensatsiyasi o'chirilgan. Litiy rejimi bo'lmagan kontrollerlar akkumulyatorni to'liq zaryadlamaydi.

16. Tashqi balanslagich kerakmi?

Yo'q. BMS 14.4V da passiv balanslashni amalga oshiradi (hujayra uchun 3.6V); balanslashni ishga tushirish uchun vaqti-vaqti bilan to'liq zaryad kerak — uzoq vaqt qisman zaryadlash hujayralar deltasini o'stiradi.

17. Eski va yangi akkumulyatorlarni aralashtirish mumkinmi?

Yo'q. Ishlatilgan blokning ichki qarshiligi yuqoriroq va zanjirda qayta-qayta ortiqcha zaryadlanib, chuqur razryadlanadi; butun zanjirni bir xil model, sig'im va partiya bilan almashtiring.

18. Akkumulyator nima uchun shishadi?

Odatda maxsus bo'lmagan zaryadlovchidan ortiqcha zaryad, uzoq muddatli yuqori harorat, ichki qisqa tutashuv yoki ishdan chiqqan BMS. Shishish qaytarilmas — foydalanishni to'xtatib, utilizatsiya qiling, hech qachon qayta zaryadlamang yoki razryadlamang.

§18. Kundalik ishlatish va parvarish (muhandislik qo'llanmasi)

Ushbu yetti bandga rioya qilsangiz, SPF12V260-ST 25℃ da kuniga bitta 80% DoD sikli bilan 5+ yil xizmat qiladi:

1. Zaryadlovchi tanlash: CV/CC va harorat himoyasiga ega sanoat zaryadlovchisidan foydalaning, CV nuqtasi 14.6V, tok chegarasi 0.2C (52A); hech qachon qo'rg'oshin-kislota tez zaryadlovchisini ishlatmang yoki generatorga to'g'ridan-to'g'ri ulamang.

2. O'rnatish muhiti: shkaf yoki stellajga o'rnating, poldan ≥200mm (namlik) va devorlardan ≥100mm (issiqlik tarqalishi); atrof-muhit −20 dan 60℃ gacha, to'g'ridan-to'g'ri quyosh yoki issiqlik manbai yo'q; yopiq makonlarda majburiy shamollatish.

3. Muntazam tekshiruv: har oyda klemma momenti (9-11 N·m) va oksidlanishni tekshiring; har chorakda hujayra deltasi (<50mV) va tashqi ko'rinishni (shishish / oqish / yoriqlar); har yili sig'im tekshiruvi.

4. Uzoq muddatli saqlash: 30-50% SOC gacha razryad qiling, quruq joyda −5 dan 35℃ gacha saqlang, har 3 oyda to'ldiring; 12 oydan ortiq saqlangan akkumulyatorlar ishlatishdan oldin to'liq zaryad/razryad talab qiladi.

5. Nosozliklarni bartaraf etish: sig'im >20% pasaygan: CV nuqtasi va hujayra balansini tekshiring; kuchlanish anormal (12.8V dan ±1.5V chetlashgan): o'sha blokni to'ldiring yoki almashtiring; shishish / oqish / hid: foydalanishni to'xtatib, ajratib qo'ying; BMS tez-tez uzilsa: kabel va yukni tekshiring.

6. Birinchi ishlatish: qabul qilganda 2 soat damdan keyin ochiq zanjir kuchlanishini (12.8-13.4V) va ichki qarshilikni o'lchang; ishga tushirishdan oldin bir marta to'liq zaryadlang va zanjirlarni balanslang (hujayra deltasi <20mV).

7. Xavfsizlik taqiqlari: hech qachon metall asbob bilan ikkala klemmni ulamang (yuzlab amper, kuyish); zaryadlash yaqinida ochiq alanga yo'q; himoya ko'zoynagi va izolyatsiyalangan qo'lqop kiying; chiqindi batareyalarni litsenziyalangan qayta ishlovchiga topshiring — hech qachon qismlarga ajratmang, yoqmang yoki tashlamang.

§18b. O'rnatish talablari — majburiy topshirish tekshiruvlari

LiFePO4 xizmat ko'rsatilmaydigan, ammo masofa, moment, muhit va zanjir mosligi xavfsizlik va xizmat muddatiga bevosita ta'sir qiladi. Quyidagilar majburiy topshirish tekshiruvlaridir:

Item

Talab

Note

Yo'nalish

Tik yoki yon tomondan (klemmalar oldinga), maksimal 90° og'ish

Hech qachon teskari emas — zichlagich va hujayra guruhi bunga yo'l qo'ymaydi

Holat

Tekshiruv va almashtirish uchun ochiq

Eng past daraja, shishish va oqishni erta ko'rish uchun

Bloklar orasidagi masofa

≥10mm tabiiy konveksiya, zich qalamang

shkaflar ichida issiqlik tarqalishi uchun ≥15mm

Issiqlik manbalaridan masofa

≥50cm

Qozon, transformator va kommutatsiya uskunasi issiqligidan uzoq tuting

Devordan / poldan masofa

≥100mm / ≥200mm

Pastdan shamollatish, namlikdan himoya

Stellaj yuki

har bir blok 30.5kg; stellaj ≥3× umumiy og'irlik

Ko'p qavatli stellajlarda polkalarni mustahkamlang

Klemma momenti

9-11 N·m

Bo'shashgan ulanish qiziydi; ortiqcha moment ustunni yoradi

Korpus himoyasi

IP65 (suvga botirmang)

Ochiq havoda yomg'irdan himoya qopqog'i qo'shing

Klemma turi bo'yicha mahkamlash momenti:

Klemma turi

Moment

Qo'llaniladigan modellar

F2 tiqma

asbobsiz, to'liq joyiga tiqing

7.2Ah / 10Ah kichik modellar

NB1 (M6 murvat)

4-5 N·m

20Ah va undan past (12V / 24V / 36V kichik modellar)

T11 / M8 murvat

9-11 N·m

35-300Ah asosiy modellar

DIN klemma (M8)

9-11 N·m

100Ah DIN qisqa / uzun korpus

Atrof-muhit talablari:

Item

Ruxsat etilgan diapazon

Note

Atrof-muhit harorati

razryad −20 dan 60℃ gacha; zaryad 0 dan 45℃ gacha

diapazondan tashqarida ko'rsatkichlar va xizmat muddati pasayadi

Yopiq makon

to'liq germetik shkafda emas

zaryad paytida gaz to'planishi shishish xavfini tug'diradi

Nisbiy namlik

≤85% RH, kondensatsiyasiz

yuqori namlik klemmalarni korroziyaga uchratadi

Balandlik

≤3000m pasaytirishsiz

3000m dan yuqorida har 1000m uchun 8% pasaytirish

Chang / korroziv gaz

tuz tumani, kislota tumani, ammiakdan saqlaning

himoya shkafi yoki qoplamadan foydalaning

Tebranish

uzluksiz tebranishdan (>2g) saqlaning

transport vositalari va qayiqlarda tebranish yostiqchalari qo'shing

Zanjir qoidalari (muhim):

Moslashtirish: zanjir ichida hujayra deltasi <50mV va ichki qarshilik farqi <15%.

Bir xil partiya: bir xil model, bir xil sig'im, bir xil partiya; partiyalarni aralashtirish eng kuchsiz hujayraning ortiqcha zaryadlanishi / chuqur razryadlanishiga olib keladi (eng kuchsiz hujayra effekti).

Ketma-ket / parallel: ma'lumotnoma 4 tagacha ketma-ket ulashga ruxsat beradi (12.8V→51.2V); parallel 4 blokgacha, avval parallel, keyin ketma-ket.

Kabellar: kabelni uzluksiz tokka qarab tanlang (1C = 260A, 1.5× zaxira); qisqa tutashuv toki faqat saqlagich tanlash uchun, kabel tanlash uchun emas.

Ulash tartibi: avval musbat, keyin manfiy klemmaga ulang; avval parallel, keyin ketma-ket; qutblarni hech qachon almashtirmang (25.6V farq BMSni bir zumda buzadi).

Ishga tushirishdan oldin: ishga tushirishdan oldin zanjirni balanslash uchun 4-8 soat to'liq zaryadlang va har bir hujayra kuchlanishini yozib oling.

Item

Spetsifikatsiya

Muhandislik izohi

Ulagich materiali

qalaylangan mis (≥0.3mm qoplama)

oksidlanishni oldini oladi, kontakt qarshiligini pasaytiradi

Kontakt qarshiligi

har bir ulanish uchun ≤0.05mΩ

ulanishdagi kuchlanish tushishi zanjir yo'qotishlarining asosiy qismi

Mahkamlash momenti

klemma turi bo'yicha (yuqoridagi jadval)

bo'sh bo'lsa qiziydi, ortiqcha tortilsa yoriladi

Korroziyadan himoya

o'tkazuvchi pasta yoki termoyopishqoq trubka

tuz / kislota tumanida majburiy

§18c. Xavfsizlik va muvofiqlik — xavf tasnifi va taqiqlar

LiFePO4 yaxshi issiqlik barqarorligiga ega, ammo yuqori kuchlanish, yuqori tok va issiqlik chiqishi baribir qat'iy o'rnatish va ishlatish qoidalarini talab qiladi:

Daraja

Ma'nosi

Odatiy holat

XAVF

Noto'g'ri ishlatish jarohat yoki o'limga olib kelishi mumkin

germetik korpus (gaz to'planishi), maxsus bo'lmagan zaryadlovchi, klemmalar ustidagi metall asbob

OGOHLANTIRISH

Jarohat yoki uskuna shikastlanishiga olib kelishi mumkin

izolyatsiyalanmagan metall korpus, uchqun yoki ochiq alanga, qutblarning almashinishi

DIQQAT

Yengil jarohat yoki zararga olib kelishi mumkin

belgilangan haroratdan tashqarida, issiqlik manbalari yaqinida, suvga cho'kish yoki namlik, to'g'ridan-to'g'ri quyosh nuri

Taqiqlar:

Taqiq

Talab

Sabab

Oksidlovchilar

kuchli oksidlovchilardan uzoq tuting

MSDSda mos kelmaydigan deb ko'rsatilgan

Kimyolarni aralashtirish

hech qachon qo'rg'oshin-kislota, NiMH yoki NMC bilan ketma-ket/parallel ulamang

turli zaryad kuchlanishi va chegaralar ortiqcha zaryad, oqish va yong'inga olib keladi

Organik erituvchilar

suyultirgich, benzin, spirt bilan tozalamang

korpusni korroziyaga uchratadi, yorilish va oqishga olib keladi

Nominal tokdan oshib ketish

hech qachon ma'lumotnomadagi maksimumdan yuqori emas

ortiqcha tok BMSni qizdiradi, shishantiradi va buzadi

Klemmalardan ushlab ko'tarish

akkumulyatorni hech qachon klemmalari yoki kabellaridan ko'tarmang

ichki guruh va zichlagichni buzadi

Pog'onali / og'ir yuklar

ustiga bosmang va og'ir narsalarni qo'ymang

korpus deformatsiyasi, ichki qisqa tutashuv

Qismlarga ajratish

korpusni ochmang va BMSni almashtirmang

yuqori kuchlanish va elektrolit xavfi, kafolat bekor

Cheklangan qo'llanishlar (yuqori ishonchlilik):

Qo'llanish

Talab

Note

Hayotni ta'minlash tibbiyoti

mustaqil zaxira tizimini talab qiladi

akkumulyator nosozligi hayotga xavf solishi mumkin

Dializ uskunasi

tavsiya etilmaydi

yuqori ishonchlilik talabi, professional baholash

Yadro / mudofaa

prohibited

maxsus notijorat sxemani talab qiladi

Avtomobil / aviatsiya / temir yo'l / dengiz boshqaruvi

taqiqlangan (yordamchi quvvatdan tashqari)

harakatlanuvchi platforma tebranishi va nosozlik oqibatlari

Suv osti uskunasi

prohibited

yuqori bosim va namlik, oqish oqibatlari

Ish himoyasi va utilizatsiya:

Item

Talab

Note

Izolyatsiyalangan asboblar

lenta bilan o'ralgan kalit, bir vaqtda bitta klemma

klemmalarning tutashib ketishini oldini oladi

PPE

izolyatsiyalangan qo'lqop, himoya ko'zoynagi, izolyatsiyalangan etik

zarba, kuyish va elektrolit sachrashi

Elektrolit bilan kontakt

teri yoki ko'zni ko'p suv bilan kamida 15 daqiqa yuvib turing va tibbiy yordamga murojaat qiling

LiPF6 gidrolizlanib HF hosil qiladi, korroziv

Chiqindini utilizatsiya qilish

litsenziyalangan qayta ishlovchiga topshiring; hech qachon qismlarga ajratmang, yoqmang yoki suvga tashlamang

litiy, temir, mis va alyuminiy qayta olinadi

Favqulodda holat bilan ishlash:

Belgi

Zudlik bilan chora

Note

Shishish / deformatsiya

foydalanishni to'xtatib, ajratib qo'ying

issiqlik chiqishining oldingi belgisi

Oqish / hid

quvvatni o'chiring, shamollating, evakuatsiya qiling

korroziv elektrolit va yonuvchi gaz

Anormal isish

zaryadlashni to'xtating, yukni uzing

zaryadlovchi va simni qisqa tutashuv yoki teskari ulanishga tekshiring

Hujayra kuchlanishining anormalligi

zanjirni balanslang, kuchsiz hujayrani alohida ishlating

>50mV chetlanish moslashtirishni talab qiladi

Fire

ko'p miqdorda sovuq suv bilan sovuting yoki quruq kukun, qum yoki tuproq bilan bosib o'chiring; hech qachon Halon ishlatmang

yonish natijasida CO, CO2, HF va fosfor ftoridlari ajraladi

Bu bo'lim eksport loyihalarining muvofiqlik tekshiruvi uchun LiFePO4 sanoat xavfsizligining asosiy amaliyotiga amal qiladi; obyekt tartiblari, mahalliy qoidalar (masalan, NFPA 70E, IEC 62485) va shartnoma shartlari ustuvor. Hayot xavfsizligi qo'llanishlari uchun loyihani litsenziyalangan elektrotexnika muhandisi ko'rib chiqishi kerak.

§19. CHISEN mahsulot salohiyati va global xizmat tizimi

Nega CHISEN ni tanlash kerak:

1. Mahsulot qatori: 20+ yil akkumulyator ilmiy-tadqiqot va ishlab chiqarishda, VRLA qo'rg'oshin-kislota, LiFePO4 modullari, BMS va energiya saqlash tizimlarini qamrab oladi; 12V / 24V / 36V / 48V bo'yicha ST / LT / BL / LB seriyalari, 7Ah dan 300Ah gacha, asosiy modellar omborda, ommaviy yetkazib berish muddati odatda 7-15 kun, buyurtma tasdiqlanishiga bog'liq.

2. Global xizmat tarmog'i: 60+ eksport mamlakati (Xitoy / Janubi-Sharqiy Osiyo / Yevropa / Afrika / Yaqin Sharq / Lotin Amerikasi / Markaziy Osiyo / Okeaniya), telekom, energetika, ma'lumotlar markazi, PV, RV-dengiz va tibbiy loyiha tajribasi; ko'p tilli texnik hujjatlar va yordam (EN / CN / ES / FR / AR / RU).

3. Sifat nazorati: jo'natishdan oldin har bir blokda kuchlanish va ichki qarshilik tekshiriladi, sig'im va tashqi ko'rinish partiya bo'yicha tanlanadi; asosiy jarayonlarda SPC (hujayra saralash, BMS sinovi, yig'ish, zichlash); uchinchi tomon tekshiruvi tashkil etilishi mumkin.

4. Eksport ko'magi: CE muvofiqlik deklaratsiyasi va birlamchi bojxona hujjatlari (hisob-faktura / qadoqlash varaqasi / CO / MSDS / UN38.3 / dengiz transporti identifikatsiyasi / zavod sinov hisoboti); ko'p tilli texnik hujjatlar (EN / CN / ES / FR / AR / RU); manzil mamlakat ruxsatnomalari so'rov bo'yicha hal qilinadi.

5. Uzoq muddatli hamkorlik: uzoq muddatli mijozlar uchun maxsus texnik aloqa; OEM hamkorlar sotuv lidlari va o'qitishni bo'lishishi mumkin; chegirmalar, ustuvor yetkazib berish va yangi mahsulot sinovlari shartnomada belgilangan.

6. Barqarorlik: LiFePO4 litiy, temir, mis va alyuminiy bo'yicha qayta ishlanadi; RoHS / REACH bo'yicha deklaratsiyalar sinov natijalariga muvofiq; manzil mamlakat ekologik va bozorga kirish talablari mijoz ehtiyojiga ko'ra hal qilinadi.

§20. Aloqa — 1 ish kuni ichida javob

CHISEN — 20+ yildan beri akkumulyatorlarga ixtisoslashgan, 60+ mamlakatga eksport qiladi.

Elektron pochta: sales@chisen.cn (narx taklifi va sig'im hisobi bir ish kuni ichida)

Tel / WhatsApp: +86 131 6622 6999

Veb-sayt: https://www.chisen.cn

Joylashuv: ishlab chiqarish bazasi: Guangdong provinsiyasi (LiFePO4 modullari va BMS yig'ish); sotuv va texnik yordam: Hangzhou, Zhejiang.

Izoh: bu sahifadagi raqamlar tanlov uchun joriy ma'lumotnomadan olingan. Spetsifikatsiyalar ogohlantirishsiz o'zgarishi mumkin; shartnoma va tovar bilan birga yuborilgan ma'lumotnoma ustuvor. Sertifikatlar, sinov hisobotlari va manzil mamlakat ruxsatnomalari har bir model uchun beriladi.