Search

CHISEN FA(G)12-100 12V 100Ah AGM Front Terminal Battery

QR code
FA(G)12-100 is a 12V 100Ah AGM Front Terminal Battery from CHISEN for Telecom Racks & Outdoor Cabinets: shallow-cycle duty, 12-year float design life.
产品详情

FA(G)12-100 12V 100Ah (10hr) Front Terminal Battery | CHISEN

Built to DL/T 637-2019 | Designed and manufactured to standard requirements

30-Second Overview

Model: FA(G)12-100 (12V, 100Ah (10hr))

Technology: AGM VRLA, FA(G) 12V front-terminal series (12V 55-200Ah)

Highlights: shallow-cycle duty / 12 years (20°C) float design life

Typical use: Telecom Racks & Outdoor Cabinets

▎ 1. Product Definition

FA(G)12-100 is a 12V 100Ah (10hr) AGM VRLA battery from CHISEN, designed for Telecom Racks & Outdoor Cabinets.

Configuration: Telecom Racks & Outdoor Cabinets. System voltages: 12V/48V/108V/216V (for 110V/220V systems).

▎ 2. Key Specifications

Parameter

Value

Model

FA(G)12-100

Series

FA(G) 12V front-terminal series (12V 55-200Ah)

Nominal voltage

12V

Rated capacity

100Ah (10hr)

Dimensions (L×W×H)

395×110×287 mm

Total height

287 mm

Approx. weight

32.35 kg (±2%)

Terminal

Φ16-M8 front-access terminal (torque 8-10 N·m)

Housing

ABS engineering plastic

Discharge rate

C10 (10-hour rate, 1.80Vpc)

Float voltage (25°C)

13.5V (2.25V/cell), -3mV/°C/cell

Equalize voltage (25°C)

14.1V (2.35V/cell), -5mV/°C/cell

Max. charge current

25A (0.25C)

Internal resistance

approx. 5.7 mΩ (1kHz, 25°C fully charged)

Short-circuit current

approx. 2100A (estimated from 1kHz AC resistance, not a test value)

Float design life

12 years (20°C float)

Cycle life

shallow-cycle duty

Standard

DL/T 637-2019 (Stationary VRLA batteries for power systems)

Certification

Third-party inspection/testing on request

System voltages

12V/48V/108V/216V (for 110V/220V systems)

Applications

Telecom Racks & Outdoor Cabinets

 

▎ 3. Construction

Positive plate:

Pb-Ca/Sn-Ca alloy grid with 4BS active material, 1.5-5mm by capacity.

Negative plate:

Pb-Ca alloy grid with carbon and humic acid additives; high hydrogen overpotential.

Separator:

AGM glass-fibre or GEL-specific microporous separator, 1.5-3mm.

Electrolyte:

Nano silica GEL (GEL type) or dilute sulfuric acid absorbed in AGM (AGM type).

Housing:

ABS engineering plastic

Terminal:

Φ16-M8 front-access terminal (torque 8-10 N·m)

Safety valve:

One-way valve, opens 10-35 kPa, closes 5-15 kPa.

▎ 4. Series Capacity Range

No.

Model

V

Ah

L

W

H

Total H

kg

Terminal

1

FA(G)6-200

6

200

363

125

250

250

31.5

Φ16-M8

2

FA(G)12-55

12

55

277

105

222

222

17.90

Φ14-M6

3

FA(G)12-100

12

100

395

110

287

287

32.35

Φ16-M8 front-access terminal

4

FA(G)12-100H

12

100

291

125

367.5

370.5

33.45

Φ16-M8

5

FA(G)12-125

12

125

558

112

295

295

42.50

Φ16-M8

6

FA(G)12-150

12

150

558

112

295

295

45.80

Φ16-M8

7

FA(G)12-155

12

155

558

112

295

295

48.50

Φ16-M8

8

FA(G)12-160

12

160

560

125

316

316

47.80

Φ19-M8

9

FA(G)12-170

12

170

560

125

316

316

50.80

Φ19-M8

10

FA(G)12-180

12

180

560

125

316

316

52.10

Φ19-M8

11

FA(G)12-200

12

200

560

125

316

316

58.1

Φ19-M8

12

FA(G)12-170A

12

170

560

125

316

316

52.8

Φ19-M8

 

▎ 5. Applications

Typical applications: Telecom Racks & Outdoor Cabinets.

Reference cases are available on request; project details are confidential.

▎ 6. Discharge Performance

Discharge time

Current

Capacity

Power

1 HR

55.0A

55 Ah

approx. 94 W/cell

3 HR

29.3A

88 Ah

approx. 50 W/cell

5 HR

19.0A

95 Ah

approx. 33 W/cell

10 HR

10.0A

100 Ah

approx. 18 W/cell

20 HR

5.0A

100 Ah

approx. 9 W/cell

 

▎ 7. Charging Parameters

Stage

Voltage

Current

Application

float

2.25V/cell (12V 13.5V)

<0.50A (≈500mA)

 

equalize (constant-voltage current-limited)

2.35V/cell (12V 14.1V)

0.1C = 10.00A (recommended) / 0.25C = 25A (max)

 

cycle charging

2.35-2.45V/cell

0.2C = 20.00A (PV cycling duty)

 

charge temperature compensation

-3mV/°C/cell (float) / -5mV/°C/cell (equalize)

—

 

 

▎ 8. Float Voltage and Temperature Compensation

Float voltage: 13.5V (2.25V/cell), -3mV/°C/cell.

Equalize voltage: 14.1V (2.35V/cell), -5mV/°C/cell.

Temperature compensation: -3mV/°C/cell float, -5mV/°C/cell equalize. Float life halves for every 10°C rise (Arrhenius).

▎ 9. Storage and Maintenance

• Store fully charged, dry and ventilated, -20 to +40°C, away from sunlight and solvents.

• Recharge every 3-6 months at constant voltage; test capacity after 12 months storage.

• Install upright; keep 200mm above floor and 100mm from walls.

• Check terminal torque every 6 months; do not mix different capacity or age in one string.

▎ 10. FAQ

What is the float voltage?

13.5V (2.25V/cell), -3mV/°C/cell

What is the design life?

12 years (20°C); shallow-cycle duty.

What is the internal resistance?

approx. 5.7 mΩ (1kHz, 25°C fully charged)

What terminal and torque?

Φ16-M8 front-access terminal (torque 8-10 N·m)

Which standard?

DL/T 637-2019 — Stationary VRLA batteries for power systems.

OEM/ODM available?

Yes. Housing colour, logo, packaging and labels can be customised; MOQ 200+ units, 30-45 days.

▎ 11. Contact

Email: sales@chisen.cn (quotation within 24h)

Tel / WhatsApp: +86 131 6622 6999

Website: https://www.chisen.cn