Chisen OPzS2-2000- Comprehensive Analysis of the Tubular Flooded Battery

2026-08-08 10:00 Chisen Battery
  • Chisen OPzS2-2000: Comprehensive Analysis of the Tubular Flooded Battery
  • Chisen OPzS2-2000 is a 2V 2000Ah tubular flooded lead-acid battery (dimensions 399×210×771 mm, weight 105.5 kg) with a design float life of 20+ years, designed for energy storage for very large applications. The OPzS2 series belongs to the vented tubular flooded lead-acid family, featuring tubular positive plates and transparent containers, in line with the classic European OPzS technology. (Source: Chisen OPzV/OPzS specification table)

  • 1. Product Overview
  • The number "2000" in OPzS2-2000 denotes the rated capacity (C10 discharge rate) in ampere-hours (Ah). As a member of the Chisen tubular flooded battery series, it retains the same tubular grid process and reliability standards while covering energy storage for very large applications applications with 2000Ah, balancing performance and cost.

    Key specifications:

    Model
    OPzS2-2000
    Rated Voltage
    2V
    Rated Capacity (C10)
    2000Ah
    Dimensions L×W×H (mm)
    399×210×771
    Total Height (mm)
    826
    Battery Weight (kg)
    105.5
    Terminal Type
    Φ20-M8 female thread

  • 2. Technical Principles
  • The OPzS2 follows the internationally mainstream OPzS technology: positive plates are tubular grids cast from low-antimony alloy, negative plates use lead-calcium alloy, and the electrolyte is high-purity, low-density dilute sulfuric acid (flooded). The tubular positive plates wrap the active material inside corrosion-resistant tubes, delivering long life and excellent cycling performance; the transparent container makes electrolyte level and plate condition clearly visible, facilitating regular water refills and maintenance — a classic, economical solution for medium and large DC backup power.

  • 3. Applications
  • Thanks to its 20+ year float life and excellent deep-discharge capability, the Chisen OPzS2-2000 is mainly suitable for the following energy storage for very large applications applications:

  • DC backup power for large power hubs
  • Backup power for nuclear plants / critical infrastructure
  • Grid-side / generation-side energy storage
  • Large-scale off-grid energy projects
  • In these scenarios, when the mains power is interrupted or fluctuates, the OPzS2-2000 quickly takes on the backup/energy storage role, keeping critical equipment powered.

  • 4. Performance Advantages
  • Design float life of 20+ years, in compliance with IEC 60896-11 and DIN 40736
  • Low-antimony positive + lead-calcium negative, low self-discharge and long maintenance intervals
  • High thermal capacity, no thermal runaway risk, high safety
  • Transparent container, visible electrolyte level and condition, intuitive maintenance
  • Tubular positive plates, long cycle life, deep-discharge resistant
  • Integrated explosion-proof safety valve; optional catalyst plug further reduces hydrogen/oxygen recombination loss
  • The 2000Ah capacity, combined with its energy storage for very large applications positioning, strikes a good balance between backup duration and budget.

  • 5. Usage & Maintenance
  • OPzS2 is a flooded battery. Check the electrolyte level and density periodically as per the manual, add deionized water as needed, and keep the battery room well ventilated. The transparent container makes inspection easy; with correct charging parameters, its 20+ year design life can be fully utilized.

    Reference charging parameters: float voltage 2.23V (25℃), temperature compensation -3mV/℃, equalize voltage 2.35V, cycle charging 2.40–2.45V, max charging current 0.20C10A. Use a charger that meets the specification and avoid overcharging or undercharging.

  • 6. Selection Advice & Market Outlook
  • As demand for reliable backup power in telecom, power and data center infrastructure keeps growing, the value of long-life tubular batteries is increasingly evident. The OPzS2-2000, as a 2000Ah model in the Chisen series, is well suited as a standard option or upgrade for energy storage for very large applications. When replacing existing batteries or planning new projects, please provide the system voltage and backup duration so the Chisen engineering team can prepare a configuration and total cost of ownership (TCO) proposal.

    【Cooperation & Inquiries】

    For the full datasheet, technical parameters and performance test report of the Chisen tubular flooded battery OPzS2-2000, or to apply for a paid sample, please feel free to contact the Chisen battery sales department.

    Global contact: 📱 Phone / WhatsApp: +86 131 6622 6999 📧 Email: sales@chisen.cn or chisenbattery@gmail.com