Three weeks after a container of 6-DZF-20 blocks was signed for, a dealer found four blocks that would not hold charge. The supplier asked three questions: what was the open-circuit voltage on arrival, what was the pack voltage at handover, and which charger ran the first cycle. There was no answer on file, so the four blocks were treated as unproven. The blocks may have been fine. The paper trail was not.
This article sets out a dealer-side process with three gates — unboxing, open-circuit voltage (OCV) and a recorded test ride — plus the numbers to write down at each gate. It is written for workshops and distributors receiving 12 V lead-acid blocks for e-bikes, e-scooters and light electric vehicles; the same structure works for the 6-DMF and EVF series.
Work from the packing list, not from memory. Open at least one carton per pallet, and every carton if the shipment moved by sea with transhipment.
Write the date, container number, carton count and every exception on one sheet and keep it for at least the warranty period. This sheet is the first document an OEM will ask for.
OCV tells you state of charge, not capacity, and it only means something after the block has rested. A block measured straight off a truck that spent two days at 45 °C reads high; one measured in an unheated warehouse at 0 °C reads low. Let the blocks rest 4–8 hours at room temperature for the first reading, then re-read any block that fails.
| OCV per 12 V block at 25 °C, rested 4–8 h | Interpretation | Dealer action |
|---|---|---|
| at or above 12.70 V | Full or close to it | Release to stock |
| 12.40–12.69 V | Normal for a block that has been stored | Release, log the value |
| 12.10–12.39 V | Roughly half to three-quarters charged | Top up before first delivery; do not store further at this level |
| 11.90–12.09 V | Deeply discharged for a new block | Quarantine, one full charge at 0.28I2, re-read after rest |
| below 11.90 V | Sulphated or internally shorted | Do not release; photograph and open the claim the same week |
Two practical notes. First, correct the reading: a rested block drops roughly 0.02–0.03 V per 12 V for every 10 °C below 25 °C, so 12.70 V measured at 5 °C corresponds to about 12.75 V at 25 °C. Second, use a meter that resolves 0.01 V and touch the post itself, not the clamp — a 0.15 V drop across a corroded clamp is the most common false alarm in an intake inspection.
Charge before delivery, then ride. A 12 V block takes a finish voltage of 14.7–14.9 V, with 14.8 V recommended, at 0.25–0.30I2 with 0.28I2 recommended, and temperature compensation of −3.0 mV/°C. Put the charger model and its measured output on the handover sheet: a large share of “failed in a week” cases ends with a charger set for a different chemistry or a different number of blocks in series.
For the test ride, record pack voltage before the ride, distance, terrain, ambient temperature, load class and pack voltage after the ride. Two numbers matter most: the resting pack voltage ten minutes after the ride, which should recover to at least 12.2 V per 12 V block, and the range against the baseline you set for that model. A single weak block in a four-block series pack shows up here as a pack that sags early even when every block passed the OCV gate, so read per-block voltage after the ride whenever the pack is accessible.
| Field | Why it is worth writing down |
|---|---|
| Block model, weight grade, date code | Links a later claim to one production batch without guesswork |
| OCV per block on arrival, rest time, temperature | Separates transport discharge from a defect |
| Charger model, output, charge start and end | Rules out overcharging or undercharging before the supplier is asked to pay |
| Test ride distance, load, ambient temperature | Turns a range complaint into a figure you can compare with a baseline |
| Photos: label, terminals, carton, meter display | A photograph of a 12.01 V reading is worth more than the figure typed into an email |
The 6-DZF and 6-DMF blocks we supply are produced and tested to GB/T 22199.1-2025 and T/ZJXDC 001-2021, and the EVF series to GB/T 32620.1-2016 and GB/T 32620.2-2016. Those are the standards named on the accompanying documents. Your own acceptance thresholds remain a commercial decision and can be tighter — the OCV table above is a starting point, not a replacement for your warranty terms.
A dealer who runs these three gates settles most routine complaints inside the workshop. A low-OCV block is charged and re-read before anyone files a claim, a charger mismatch is caught at handover, and a genuine defect reaches the supplier with a photograph, a reading and a date attached. That is the difference between a claim and an argument.
ZHEJIANG CHISEN BATTERY CO.,LTD manufactures 6-DZF, 6-DMF and EVF lead-acid blocks for e-bikes, e-scooters, wheelchairs, golf carts and light electric vehicles, and works with OEM and wholesale buyers on custom labelling, nameplates in the buyer’s language and the export documentation the destination market requires. If you are setting up a receiving process for a new range, send us the model list and the destination port and we will confirm the weight grade, terminal type and the documents we can issue for that order.