Search

GFM Series Valve-Regulated Sealed Lead-Acid Battery (VRLA)

QR code
The CHISEN GFMJ series uses nano colloid electrolyte, which improves the phenomenon of electrolyte stratification. Combined with thick electrode plates and thin anti-corrosion alloy, it has better float life and cycle life than GFM, and enhances high temperature resistance, overcharge resistance, and over discharge performance. It is particularly suitable for scenarios with certain requirements for cycling performance or high ambient temperatures.
产品详情

Product Introduction

The CHISEN GFM Medium-Density Series employs AGM technology, thick plates, and corrosion-resistant alloys, delivering exceptional float service life and cycle life. With superior high-current discharge performance, low self-discharge rate, and reliability, it is ideal for backup power applications such as UPS/EPS switchgear, cable TV systems, and telecommunication systems.



Features & Benefits

  1. Float Service Life: 12 years (at 20°C).

  2. Wide Operating Temperature Range: -20°C to 60°C.

  3. High-Tin, Low-Calcium Alloy & Reinforced Grid Design: Enhances durability and corrosion resistance.

  4. Flexible Installation: Supports horizontal or sideways placement.

  5. Low Self-Discharge: Extended shelf life during storage.

  6. Outstanding Deep-Discharge Recovery: Reliable performance under repeated deep cycles.


Structural Specifications

  1. Positive Plate Grid: Thickened high-tin, low-calcium alloy plate.

  2. Negative Plate Grid: Lead-calcium alloy plate.

  3. Separator: Enhanced AGM (Absorbent Glass Mat) separator.

  4. Electrolyte: High-purity dilute sulfuric acid.

  5. Casing: ABS plastic.

  6. Terminal Seal: Dual epoxy resin sealing.

  7. Safety Valve: EPDM (Ethylene Propylene Diene Monomer) rubber.



Recommended Charging Parameters

  1. Charging Method: Voltage- and current-limited charging.

  2. Float Charge Voltage: 2.27V/cell @25°C.

  3. Float Voltage Temperature Compensation: -3mV/°C/cell.

  4. Equalization Charge Voltage: 2.35V/cell @25°C.

  5. Maximum Charging Current: 0.25C₁₀A (where C₁₀ = rated capacity at 10-hour discharge rate).


Application areas

  1. UPS/EPS: Uninterruptible Power Supply / Emergency Power System

  2. Switchgear Equipment: Power distribution and control systems.

  3. Telecommunications: Communication infrastructure and devices.

  4. Security Systems: Surveillance, access control, and alarm systems.

  5. Emergency Lighting Power Sources: Backup lighting for critical scenarios.

  6. Toys: Battery-powered recreational or educational devices.

  7. Power Systems & Post & Telecommunications Systems: Electrical grids and postal/telecom networks.

  8. Solar/Wind Energy Generation Systems: Renewable energy storage solutions.

  9. Medical Equipment: Devices requiring reliable backup power (e.g., hospital instruments).




CHISEN GFMJ series high performance valve-regulated sealed lead-acid battery model parameter table

Fixed valve-regulated sealed lead-acid battery below 38Ah (C10 capacity)












Serial  
number

Rated

voltage (V)

Discharge

rate (hr)

Capacity

(Ah)

Battery   dimensions(mm±2mm)

Battery  

Standard   terminal

specifications

Terminal

height(mm)

long

Width

high

Height

weight  

(kg)

6-GFM-40

12

10

40

197

165

176

176

12.25

φ16-M6

5

6-GFM-45

12

10

45

197

165

176

176

13.20

φ16-M6

5

6-GFM-50

12

10

50

350

167

180

180

17.60

φ14-M6

5

6-GFM-55

12

10

55

229

138

210

215

17.30

φ16-M6

5

6-GFM-65

12

10

65

350

167

180

180

19.45

φ14-M6

5

6-GFM-70

12

10

70

266

168

208

213

22.25

φ16-M6

5

6-GFM-80

12

10

80

266

168

208

213

24.05

φ16-M6

5

6-GFM-80A

12

10

80

330

174

215

220

25.20

φ20-M8

5

6-GFM-90

12

10

90

306.5

168

208.5

211

26.00

φ16-M6

5

6-GFM-90A

12

10

90

330

174

215

220

27.30

φ20-M8

5

6-GFM-100

12

10

100

330

174

215

220

30.00

φ20-M8

5

6-GFM-100A

12

10

100

330

174

215

220

28.00

φ20-M8

5

6-GFM-120

12

10

120

408

177

224

224

35.00

φ16-M8

5

6-GFM-120A

12

10

120

408

177

224

224

33.00

φ16-M8

5

6-GFM-150

12

10

150

483

170

240

240

45.20

φ20-M8

5

6-GFM-150A

12

10

150

483

170

240

240

42.00

φ20-M8

5

6-GFM-180

12

10

180

532

207

220

225

53.30

φ20-M8

5

6-GFM-180A

12

10

180

520

240

217

222

53.90

φ20-M8

5

6-GFM-200

12

10

200

520

240

217

222

59.75

φ20-M8

5

6-GFM-200A

12

10

200

520

240

217

222

57.20

φ20-M8

5

6-GFM-220

12

10

220

525

267

220

225

63.70

φ20-M8

5

6-GFM-230

12

10

230

520

239

217

222

64.50

φ20-M8

5

6-GFM-250

12

10

250

525

268

220

225

71.30

φ20-M8

5

6-GFM-250A

12

10

250

525

268

220

225

67.80

φ20-M8

5


Fixed valve-regulated sealed lead-acid battery above 38Ah (C20 capacity)

Serial  
number

Rated

voltage (V)

Discharge

rate (hr)

Capacity

(Ah)

Battery   dimensions(mm±2mm)

Battery  

Standard   terminal

specifications

Terminal

height(mm)

long

Width

high

Height

weight   (kg)

6-GFM-38A

12

20

38

197

165

176

176

11.20

φ16-M6

5

6-GFM-45A

12

20

45

197

165

176

176

12.25

φ16-M6

5

6-GFM-50A

12

20

50

197

165

176

176

13.20

φ16-M6

5

6-GFM-38B

12

20

65

350

167

180

180

15.00

φ14-M6

5

6-GFM-65B

12

20

65

350

167

180

180

17.60

φ14-M6

5

6-GFM-100B

12

20

100

306.5

168

208.5

211

28.30

φ20-M8

5

6-GFM-100C

12

20

100

330

174

215

220

27.30

φ20-M8

5

6-GFM-120B

12

20

120

408

177

224

224

32.00

φ16-M8

5

6-GFM-150B

12

20

150

483

170

240

240

41.20

φ20-M8

5

6-GFM-200B

12

20

200

520

240

217

222

55.40

φ20-M8

5

6-GFM-200C

12

20

200

532

207

220

225

57.00

φ20-M8

5