Product Introduction
The CHISEN GFM Medium-Density Series employs AGM technology, thick plates, and corrosion-resistant alloys, delivering exceptional float service life and cycle life. With superior high-current discharge performance, low self-discharge rate, and reliability, it is ideal for backup power applications such as UPS/EPS switchgear, cable TV systems, and telecommunication systems.
Float Service Life: 12 years (at 20°C).
Wide Operating Temperature Range: -20°C to 60°C.
High-Tin, Low-Calcium Alloy & Reinforced Grid Design: Enhances durability and corrosion resistance.
Flexible Installation: Supports horizontal or sideways placement.
Low Self-Discharge: Extended shelf life during storage.
Outstanding Deep-Discharge Recovery: Reliable performance under repeated deep cycles.
Positive Plate Grid: Thickened high-tin, low-calcium alloy plate.
Negative Plate Grid: Lead-calcium alloy plate.
Separator: Enhanced AGM (Absorbent Glass Mat) separator.
Electrolyte: High-purity dilute sulfuric acid.
Casing: ABS plastic.
Terminal Seal: Dual epoxy resin sealing.
Safety Valve: EPDM (Ethylene Propylene Diene Monomer) rubber.
Charging Method: Voltage- and current-limited charging.
Float Charge Voltage: 2.27V/cell @25°C.
Float Voltage Temperature Compensation: -3mV/°C/cell.
Equalization Charge Voltage: 2.35V/cell @25°C.
Maximum Charging Current: 0.25C₁₀A (where C₁₀ = rated capacity at 10-hour discharge rate).
Application areas
UPS/EPS: Uninterruptible Power Supply / Emergency Power System
Switchgear Equipment: Power distribution and control systems.
Telecommunications: Communication infrastructure and devices.
Security Systems: Surveillance, access control, and alarm systems.
Emergency Lighting Power Sources: Backup lighting for critical scenarios.
Toys: Battery-powered recreational or educational devices.
Power Systems & Post & Telecommunications Systems: Electrical grids and postal/telecom networks.
Solar/Wind Energy Generation Systems: Renewable energy storage solutions.
Medical Equipment: Devices requiring reliable backup power (e.g., hospital instruments).
CHISEN GFMJ series high performance valve-regulated sealed lead-acid battery model parameter table
Fixed valve-regulated sealed lead-acid battery below 38Ah (C10 capacity)
Serial | Rated voltage (V) | Discharge rate (hr) | Capacity (Ah) | Battery dimensions(mm±2mm) | Battery | Standard terminal specifications | Terminal height(mm) | |||
long | Width | high | Height | weight (kg) | ||||||
6-GFM-40 | 12 | 10 | 40 | 197 | 165 | 176 | 176 | 12.25 | φ16-M6 | 5 |
6-GFM-45 | 12 | 10 | 45 | 197 | 165 | 176 | 176 | 13.20 | φ16-M6 | 5 |
6-GFM-50 | 12 | 10 | 50 | 350 | 167 | 180 | 180 | 17.60 | φ14-M6 | 5 |
6-GFM-55 | 12 | 10 | 55 | 229 | 138 | 210 | 215 | 17.30 | φ16-M6 | 5 |
6-GFM-65 | 12 | 10 | 65 | 350 | 167 | 180 | 180 | 19.45 | φ14-M6 | 5 |
6-GFM-70 | 12 | 10 | 70 | 266 | 168 | 208 | 213 | 22.25 | φ16-M6 | 5 |
6-GFM-80 | 12 | 10 | 80 | 266 | 168 | 208 | 213 | 24.05 | φ16-M6 | 5 |
6-GFM-80A | 12 | 10 | 80 | 330 | 174 | 215 | 220 | 25.20 | φ20-M8 | 5 |
6-GFM-90 | 12 | 10 | 90 | 306.5 | 168 | 208.5 | 211 | 26.00 | φ16-M6 | 5 |
6-GFM-90A | 12 | 10 | 90 | 330 | 174 | 215 | 220 | 27.30 | φ20-M8 | 5 |
6-GFM-100 | 12 | 10 | 100 | 330 | 174 | 215 | 220 | 30.00 | φ20-M8 | 5 |
6-GFM-100A | 12 | 10 | 100 | 330 | 174 | 215 | 220 | 28.00 | φ20-M8 | 5 |
6-GFM-120 | 12 | 10 | 120 | 408 | 177 | 224 | 224 | 35.00 | φ16-M8 | 5 |
6-GFM-120A | 12 | 10 | 120 | 408 | 177 | 224 | 224 | 33.00 | φ16-M8 | 5 |
6-GFM-150 | 12 | 10 | 150 | 483 | 170 | 240 | 240 | 45.20 | φ20-M8 | 5 |
6-GFM-150A | 12 | 10 | 150 | 483 | 170 | 240 | 240 | 42.00 | φ20-M8 | 5 |
6-GFM-180 | 12 | 10 | 180 | 532 | 207 | 220 | 225 | 53.30 | φ20-M8 | 5 |
6-GFM-180A | 12 | 10 | 180 | 520 | 240 | 217 | 222 | 53.90 | φ20-M8 | 5 |
6-GFM-200 | 12 | 10 | 200 | 520 | 240 | 217 | 222 | 59.75 | φ20-M8 | 5 |
6-GFM-200A | 12 | 10 | 200 | 520 | 240 | 217 | 222 | 57.20 | φ20-M8 | 5 |
6-GFM-220 | 12 | 10 | 220 | 525 | 267 | 220 | 225 | 63.70 | φ20-M8 | 5 |
6-GFM-230 | 12 | 10 | 230 | 520 | 239 | 217 | 222 | 64.50 | φ20-M8 | 5 |
6-GFM-250 | 12 | 10 | 250 | 525 | 268 | 220 | 225 | 71.30 | φ20-M8 | 5 |
6-GFM-250A | 12 | 10 | 250 | 525 | 268 | 220 | 225 | 67.80 | φ20-M8 | 5 |
Fixed valve-regulated sealed lead-acid battery above 38Ah (C20 capacity) | ||||||||||
Serial | Rated voltage (V) | Discharge rate (hr) | Capacity (Ah) | Battery dimensions(mm±2mm) | Battery | Standard terminal specifications | Terminal height(mm) | |||
long | Width | high | Height | weight (kg) | ||||||
6-GFM-38A | 12 | 20 | 38 | 197 | 165 | 176 | 176 | 11.20 | φ16-M6 | 5 |
6-GFM-45A | 12 | 20 | 45 | 197 | 165 | 176 | 176 | 12.25 | φ16-M6 | 5 |
6-GFM-50A | 12 | 20 | 50 | 197 | 165 | 176 | 176 | 13.20 | φ16-M6 | 5 |
6-GFM-38B | 12 | 20 | 65 | 350 | 167 | 180 | 180 | 15.00 | φ14-M6 | 5 |
6-GFM-65B | 12 | 20 | 65 | 350 | 167 | 180 | 180 | 17.60 | φ14-M6 | 5 |
6-GFM-100B | 12 | 20 | 100 | 306.5 | 168 | 208.5 | 211 | 28.30 | φ20-M8 | 5 |
6-GFM-100C | 12 | 20 | 100 | 330 | 174 | 215 | 220 | 27.30 | φ20-M8 | 5 |
6-GFM-120B | 12 | 20 | 120 | 408 | 177 | 224 | 224 | 32.00 | φ16-M8 | 5 |
6-GFM-150B | 12 | 20 | 150 | 483 | 170 | 240 | 240 | 41.20 | φ20-M8 | 5 |
6-GFM-200B | 12 | 20 | 200 | 520 | 240 | 217 | 222 | 55.40 | φ20-M8 | 5 |
6-GFM-200C | 12 | 20 | 200 | 532 | 207 | 220 | 225 | 57.00 | φ20-M8 | 5 |