Search

CHISEN SPF48V24-ST 51.2V 24Ah LiFePO4 Battery

QR code
CHISEN SPF48V24-ST: 51.2V 24Ah (1229Wh) LiFePO4 battery, 16S + BMS, drop-in for the same lead-acid / AGM / GEL battery. ≥2000 cycles at 80% DoD, 7.8kg, for Telecom 48V backup, Home ESS.
产品详情

CHISEN SPF48V24-ST 51.2V 24Ah LiFePO4 Battery | Lead-Acid Replacement / Maintenance-Free | OEM Factory Direct

30-Second Overview of CHISEN SPF48V24-ST

Model: SPF48V24-ST (51.2V 24Ah / 1229Wh, 16 LiFePO4 cells in series)

Technology: LiFePO4 cells + integrated BMS (over-charge / over-discharge / over-current / short circuit / temperature protection) + ABS case (IP65) + copper-core terminals

Highlights: ≥2000 cycles @80% DoD (4-6× lead-acid); 7.8kg pack, about 40% of the lead-acid weight; maintenance-free; direct 48V selection, no series connection needed

Typical use: Telecom 48V backup, Home ESS, Golf cart 48V, Forklift / AGV

§1. Product Definition and Four Core Advantages

CHISEN SPF48V24-ST is a 51.2V 24Ah (1229Wh) LiFePO4 battery with 16 cells in series and an integrated BMS, packaged in a 24 group case with the same footprint and terminal positions as the equivalent lead-acid / AGM / GEL battery, so the battery bay, hold-down and wiring need no change.

The ST series fits both motive and storage duty — electric vehicles, energy storage systems, defense and security, telecom outdoor, renewable energy and other harsh environments. For storage, size the capacity by backup time and daily energy; for motive duty, by continuous / peak current and range.

Configuration: 16S × 3.2V = 51.2V, 24Ah, 1229Wh; the BMS does cell-voltage sensing, passive balancing (balance point 57.6V) and over-charge / over-discharge / over-current / short-circuit / high-low temperature protection, with common charge-discharge port.

Charge / discharge: recommended CC/CV with 58.4V (16×3.65V) and 4.8A (0.2C), 24A maximum; max continuous discharge 24A (1.00C), peak 48A (3s), BMS cut-off 40V (16×2.5V).

Applications: Telecom 48V backup, Home ESS, Golf cart 48V, Forklift / AGV, Edge data centre.

CHISEN has focused on batteries for 20+ years, exporting to 60+ countries and supplying OEM/ODM customers in telecom, power, data centre, PV, RV/marine and medical-equipment sectors with cell, BMS and pack-level solutions.

Four core advantages:

1. 2000 deep cycles, about 4-6× lead-acid by cycle count: at one 80% DoD cycle per day, 2000 cycles is 5+ years of design life; lead-acid at the same duty (50% DoD, 300-500 cycles) needs a full replacement after 1 to 1.5 years. LiFePO4 does not sulphate when deep-discharged, so capacity fades gradually instead of dropping abruptly.

2. Lightweight: 7.8kg per pack against ~30.7kg for the same lead-acid capacity, about 75% lighter — easier handling, less ballast in the boat, more payload for AGVs and golf carts.

3. Maintenance-free, no water, no acid mist: sealed maintenance-free construction: no watering, no equalise charge, no acid mist and no sulphation; IP65 case, side mounting allowed (terminals forward) for tight RV, locker and cabinet spaces.

4. Five-fold BMS protection: over-charge cut at 62.4V, over-discharge cut at 40V, 72A over-current and short-circuit protection (250-500μs), 65℃ high-temperature cut-off and no charging below 0℃; the BMS disconnects and auto-recovers, preventing swelling and thermal runaway.

Also: round-trip efficiency ≥95% (typical) versus 70-85% for lead-acid, self-discharge <3%/month and 6+ months of shelf life at full charge, so the same PV array and charger put about 10-20% more energy into the battery.

§2. Key Specifications

Quick-reference specification for this model (full standards list in §4, series table in §6, charge and protection thresholds in §12 and §15).

Parameter

Value

Model

SPF48V24-ST

Series

ST Standard Type

Nominal voltage

51.2V

Nominal capacity

24Ah (10-hour rate)

Energy

1229Wh

Cell configuration

LiFePO4, 16 cells in series

Case / terminal style

24 group case

Max continuous discharge

24A (1.00C)

Peak discharge current

48A (3s)

BMS discharge cut-off current

72A ±10A (31ms)

Recommended charge voltage

58.4V (16×3.65V)

Float / standby voltage

55.2V (16×3.45V)

BMS over-charge protection

62.4V (16×3.9V)

Balancing voltage

57.6V (16×3.6V)

Recommended charge current

4.8A (0.2C)

Max charge current

24A (1.00C)

Discharge cut-off voltage

40V (16×2.5V)

Recommended low-voltage disconnect

44V (16×2.75V)

Internal resistance (1kHz, 50% SOC, 25℃)

per datasheet

Dimensions L×W×H

260×168×218 mm

Weight

7.8kg (±2%)

Terminal

T11

Terminal torque

9-11 N·m

Case material

ABS engineering plastic

Enclosure protection

IP65

Self-discharge

<3% / month (25℃)

Cycle life

≥2000 cycles @80% DoD (25℃)

Charge temperature

0 to 45℃

Discharge temperature

−20 to 60℃

Storage temperature

−5 to 35℃

Certification & documents

CE declaration of conformity (DoC) and UN38.3 test summary supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; MSDS and sea-transport identification report included

Shipping classification

UN 3480, Class 9

Note: charge and protection thresholds are calculated from the 16-cell series design (3.65V / 3.9V charge and over-charge, 3.45V float, 3.6V balance, 2.5V / 2.75V discharge and LVD). Values marked * are design values. Test reports for the exact model are available on request.

§3. Model Nomenclature — Field Breakdown

CHISEN ST series uses a segmented code (series + voltage class + capacity + type + case), so a model can be selected from the system voltage and the available space alone.

Field

Meaning

This model

SPF

Product series

SPF = LiFePO4 battery module

51.2V

Voltage class

51.2V = 16 cells × 3.2V

24

Rated capacity

24Ah at the 10-hour rate

-ST

Product type

ST = Standard Type (also LT low-temperature, BL Bluetooth, LB low-temp Bluetooth)

24 group case

Case / terminal variant

24 group case

SPF48V24-ST = SPF series + 51.2V class (16S) + 24Ah + ST standard type, 24 group case.

§4. Applicable International / Regional / Chinese Standards

The standards below are referenced for design, procurement and tender documentation.

Standard

Title

Type

Adoption

Use

IEC 62619:2022

Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for secondary lithium cells and batteries for industrial applications

International

Safety design basis

Export / industrial ESS

IEC 62133-2:2017

Secondary sealed cells and batteries — Safety requirements for portable lithium systems

International

Cell and pack safety

Export / customer acceptance

UN38.3

UN Manual of Tests and Criteria, section 38.3 — transport safety testing

International

Transport testing

Air / sea / courier

UL 1642

Standard for safety — Lithium batteries (cells)

USA

Cell safety

North America

GB 31241-2022

Lithium-ion cells and batteries for portable electronic equipment — safety technical specification

China

Design reference

Domestic sales / tenders

GB 40165-2021

Lithium-ion cells and batteries for stationary electronic equipment — safety technical specification

China

Design reference

Domestic ESS / tenders

UN 3480 Class 9

UN Model Regulations — lithium-ion batteries (standalone)

International

Transport classification

Booking / customs

Note: third-party test reports and destination approvals (e.g. EU Battery Regulation, UL 2054 pack certification) are handled per project; standards are listed for design and procurement reference.

§5. Physical Construction and Materials (LiFePO4 cells + BMS)

Construction of CHISEN SPF48V24-ST:

Cells: prismatic aluminium-shell or cylindrical steel-shell LiFePO4 cells; the olivine LiFePO4 cathode is structurally stable and does not release oxygen, which is the root of the safety margin.

Anode and electrolyte: graphite anode with LiPF6 organic electrolyte and a polyethylene (PE) separator; cells are graded for capacity, voltage and internal resistance, matching within 20mV per group.

BMS: over-charge, over-discharge, over-current, short-circuit, high/low temperature protection and passive balancing, common port; cell sensing ±25mV, balancing starts at 57.6V and closes within 20mV.

five-fold protection thresholds (per 16 cells in series):

Protection

Trigger

Recovery

Action time

Over-charge

cell ≥3.9V (pack 62.4V)

auto-recover when back to 3.6V/cell (57.6V)

instant

Over-discharge

cell ≤2.5V (pack 40V)

recover after charging above 2.8V/cell

instant

Over-current

≥72A ±10A

auto-recover after load removal

31ms

Short circuit

output shorted

auto-recover after fault cleared

250-500μs

High temperature

≥65℃

recover below 55℃

instant

Low temperature

charging ≤0℃

recover above 5℃

instant

Case and sealing: ABS engineering plastic, 24 group case, IP65; double sealing between case and lid (structural adhesive + gasket) and an O-ring at the terminal keep moisture out.

Marking: model and capacity are silk-screened or laser-marked on the front, with model, voltage, capacity, energy, production batch and warning marks.

Structural difference vs lead-acid: lead-acid (AGM / GEL) delivers 300-500 cycles to 80% capacity at 50% DoD and still needs equalise charging and terminal inspection; LiFePO4 delivers 2000+ cycles at 80% DoD with no maintenance. In the same space the usable energy is about 1.6× (80% vs 50% DoD), which is the direct value of lead-acid replacement.

Replacement warning: a lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, while this model needs 58.4V constant voltage. Keeping the lead-acid charger leaves the pack permanently under-charged, which fades capacity and defeats balancing — switch the charger to lithium mode or replace it (see §12).

§6. ST Series 51.2V Full Capacity Table (5 models)

The 51.2V platform of the ST series has 5 capacity models (LiFePO4, 16S). Models in the same voltage class are drop-in interchangeable by capacity and can be connected in series for higher system voltages.

No.

Model

V

Ah

Max A

Size mm

kg

Terminal

Case / BCI

1

SPF48V12-ST

51.2

12

20

198×166×175

5.5

T11

166 standard case

2

SPF48V24-ST

51.2

24

24

260×168×218

7.8

T11

24 group case

3

SPF48V30-ST

51.2

30

30

329×172×223

10.3

T11

31 group case

4

SPF48V48-ST

51.2

48

48

484×170×241

24

T11

compact case

5

SPF48V72-ST

51.2

72

72

520×268×228

34.2

T11

8D case

This page covers SPF48V24-ST, highlighted above: 24Ah / 1229Wh / 7.8kg.

Other voltage classes in the same series:

Class

Series

Models

Capacity range

Max discharge

Typical use

12V

4S

20

7.2-300Ah

15-150A

RV, marine, off-grid solar, telecom/CCTV, mobility and scrubbers

24V

8S

9

10-140Ah

15-140A

AGV, wheelchairs, marine, RV, solar street lights

36V

12S

6

7-96Ah

10-100A

Golf carts, tricycles, scrubbers, stackers, garden machinery

48V

16S

5

12-72Ah

20-72A

Telecom sites, home ESS, golf carts, forklifts, edge data centres

Note: do not mix capacities or batches in one string — every unit in a string must be the same model, capacity and batch (see §18b).

§7. Main Applications and Reference Cases

CHISEN SPF48V24-ST serves the following 5 applications (this model: 24Ah / 1229Wh, about 983Wh usable at 80% DoD):

Telecom 48V backup: Native 48V DC bus, maintenance-free for unattended sites.

Home ESS: Pairs with 48V hybrid inverters for peak shaving and backup.

Golf cart 48V: Direct replacement for 4×12V lead-acid blocks.

Forklift / AGV: Multi-shift duty with opportunity charging.

Edge data centre: 15-30 minutes of backup; optional BMS communication.

Every figure below is derived from this model's own capacity (DoD 0.8, inverter 0.9):

Case 1: Lighting / monitoring (sized from this model)

24Ah (1229Wh) drives a 145W load for about 6 hours at DoD 0.8 and 0.9 inverter efficiency; at 72W the runtime doubles to about 12 hours.

Case 2: Monitoring / telecom backup (sized from this model)

for a 4-hour backup the same pack supports 220W (1229Wh × 0.8 × 0.9 ÷ 4).

Case 3: Daily cycling (sized from this model)

one 80% DoD cycle per day gives 983Wh per day, about 358795Wh per year; 2000 cycles is roughly 5 years.

Case 4: Lead-acid replacement (sized from this model)

the same lead-acid capacity offers about 614Wh usable (50% DoD) against 983Wh here (80% DoD), 60% more energy, at 7.8kg versus about 30.7kg — about 75% lighter.

Case 5: Parallel expansion (sized from this model)

a single unit is 51.2V / 1229Wh; up to 4 in parallel, maximum 96Ah / 4916Wh.

§8. ST Series vs Lead-Acid / AGM / GEL — Full Comparison

Same footprint and nominal voltage, LiFePO4 against lead-acid (AGM / GEL):

Item

This series (LiFePO4 ST)

Lead-acid AGM / GEL

Conclusion

Energy density

~158 Wh/kg

~30-40 Wh/kg

2-3× the energy per kg

Cycle life

≥2000 @80% DoD

300-500 @50% DoD

4-6× lead-acid

Usable capacity

80-90% DoD

50% DoD (deeper cycles shorten life)

60% more usable energy

Round-trip efficiency

≥95%

70-85%

10-20% more from the same PV array

Self-discharge

<3% / month

3-5% / month, plus sulphation

6+ months of shelf life

Weight

7.8kg

~30.7kg

about 75% lighter

Maintenance

none

watering, equalise charge, corrosion checks

near-zero O&M

Continuous rate

1.00C (peak 2.0C)

0.2-0.3C

no sag on starts

Low-temperature discharge

~65% at −20℃ (typical)

~50% at −20℃

better for cold stores and winter

Mounting

any orientation except inverted

upright only

fits lockers and cabinets

Environment

no lead-acid electrolyte, fully recyclable

lead and sulphuric acid, higher disposal requirements

simpler recycling

Replacements in 10 years

1-2

4-6

lower total cost of ownership

§9. Selection Decision Table

Fit of this model (24Ah / 51.2V) in each application; "suitable in combination" means several units in series or parallel are needed.

Application

Fit for this model

Note

Monitoring / lighting / access control

Suitable

24Ah is enough

RV / camper house power

Not suitable

75Ah and above recommended; this model is 24Ah

Marine power / house

Not suitable

≥1C for starting; 100Ah and above

Residential off-grid solar

Not suitable

size from night consumption ÷ 0.8 DoD

Telecom / CCTV backup

Suitable

4-10 hour backup

Telecom site 48V

Suitable

direct at 48V; string other classes

Golf cart / e-tricycle

Suitable

direct at 36V / 48V; 3-4 in series from 12V

AGV / forklift

Suitable

direct at 24V / 48V; string other classes

§10. Capacity Sizing Formula and Configuration Examples

Capacity (Ah) = load (W) × backup time (h) ÷ system voltage (V) ÷ inverter efficiency ÷ depth of discharge ÷ temperature factor

Assumptions: inverter efficiency 0.85 (low-frequency) / 0.90 (high-frequency) / 1.0 (DC loads).

DoD and temperature: LiFePO4 allows 0.80-0.90 (lead-acid only 0.50); temperature factor 1.0 at 25℃, 0.90 at 0℃, 0.75 at −10℃, 0.65 at −20℃, 0.95 at 45℃; keep 20-30% ageing margin.

Sizing example 1 (51.2V system): off-grid lighting load 150W for 8h per day, inverter 0.9, DoD 0.8 → 150×8÷51.2÷0.9÷0.8 ≈ 32.6Ah — select 24Ah × 2 in parallel (48Ah total).

Pack example 2 (single battery, 51.2V / 1229Wh): at DoD 0.8 and inverter 0.9 it supports 200W for about 4.4 hours (1229×0.8×0.9÷200); at 100W the runtime doubles to about 8.8 hours.

constant-current discharge capability (25℃, typical, varies with temperature and load):

Discharge time

Current

Usable capacity

Power at 51.2V

20 HR

1.2 A

24 Ah

~61 W

10 HR

2.4 A

24 Ah

~123 W

5 HR

4.8 A

24 Ah

~246 W

3 HR

8.0 A

24 Ah

~401 W

1 HR

24.0 A

23 Ah

~1167 W

Rule of thumb: short high-current duty (UPS 30min class) needs a high-rate model, checked against the current table in §15; long low-current duty (telecom 4-10h) uses the 10HR row.

charger compatibility is where lead-acid replacements most often go wrong:

Charger type

Directly usable?

Setting

Lithium charger

Directly usable

58.4V constant voltage, current ≤4.8A (0.2C)

Existing lead-acid charger

Not directly

Switch to lithium mode (58.4V CV) or replace; temperature compensation must be off

MPPT solar controller

Must support lithium

Absorption 58.4V, float 55.2V; disable lead-acid equalise and temp compensation

Vehicle DC-DC / alternator

Must limit voltage

Output must not exceed 62.4V or the BMS over-charge protection trips

Inverter-charger

Usable

Select LiFePO4 / 4S mode, charge current 0.2C

§11. Cycle Life and Total Cost of Ownership (TCO)

Cycle life is ≥2000 cycles @80% DoD (25℃); cells still hold above 80% capacity after 2000 cycles at 1C charge/discharge, and a pack cycled at the usual 0.2C typically exceeds the rating.

TCO = purchase cost + replacements × purchase cost + maintenance + downtime loss − residual value

Item

LiFePO4 (this series)

Lead-acid AGM / GEL

Cycle life

2000 @80% DoD

350 @50% DoD

10-year cycles (one per day)

3650

3650

Packs needed over 10 years

2

11

Purchase cost index (example)

1.0

0.45 per pack

10-year purchase index

2.0

4.9

Maintenance

none

watering, equalise, corrosion checks

Downtime replacements

1

10

Cost per cycle

low

high

Note: the cost index is an illustrative assumption used only to show the replacement-count difference; request a quotation for actual project pricing.

§12. Charge Voltage Setting and Temperature Relationship

Standard charge is 58.4V (16×3.65V) CC/CV at 4.8A (0.2C), 24A maximum; float / standby is 55.2V (16×3.45V).

Stage

Voltage (25℃)

Current

Termination

Constant current (CC)

raise to 58.4V

4.8A (0.2C)

reaches 58.4V

Constant voltage (CV)

58.4V

tapering

current falls to 0.05C (~1.2A)

Float / standby

55.2V

≤0.02C

continuous

Balancing

57.6V

passive

cell delta <20mV

Charging strategy by temperature:

Temperature

Allowed current

Charge voltage

Note

< 0℃

charging prohibited

—

BMS blocks the charge path; cold stores and winter sites need heating or the LT version

0-10℃

0.1C limit

58.4V

low-temperature charge acceptance is reduced

10-25℃

0.2C

58.4V

optimum window

25-40℃

0.2-0.3C

58.4V

ensure ventilation

40-45℃

0.1C derated

58.4V

no charging above 45℃

> 45℃

charging prohibited

—

BMS high-temperature protection

LiFePO4 does not need the lead-acid (-3mV/℃/cell) temperature compensation; the BMS handles the cell thresholds, so the charger only has to hold the CV point accurately.

Replacement point: this is the step where lead-acid replacements fail most often. A lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, both below what this model needs, so the pack is permanently under-charged, cells drift apart and capacity fades quickly. Set the charger to 58.4V CV with 0.2C current limit, or replace it with a lithium charger; disable any temperature compensation.

§13. Operating Temperature Range (discharge / charge / storage)

Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; optimum 25℃ (the capacity reference point). The BMS cuts at 65℃ and recovers at 55℃.

Temperature

Usable capacity (typical)

Charging

Note

60℃ (discharge limit)

~95%

prohibited

derated; forced ventilation required

40℃

~100%

0.1C derated

avoid direct sunlight, improve cooling

25℃ (reference)

100%

0.2C

best balance of capacity and life

0℃

~90%

0.1C limit

lower charge acceptance

−10℃

~75%

prohibited

pre-heat above 0℃ before charging

−20℃ (discharge limit)

~65%

prohibited

discharge only, BMS low-temperature protection

Note: capacity varies with rate and temperature; figures are typical at 0.2C. At −20℃ LiFePO4 still delivers about 65% while lead-acid delivers about 50%, which matters for cold stores and high-altitude projects.

heat accelerates ageing: above 25℃ every 10℃ rise roughly halves cycle life, so for continuous duty above 45℃ improve ventilation, lower the charge voltage ceiling or select a high-temperature derated option.

§14. Self-Discharge Rate and Storage Conditions

Self-discharge is below 3%/month at 25℃ from full charge, so a fully charged pack still starts after 6 months; for long storage keep 30-50% SOC and top up every 3 months.

Storage temperature

Self-discharge

Recharge interval

Remaining capacity

20℃

<1.5% / month

12 months

~90%

25℃

<3% / month

6 months

~85%

35℃

<4% / month

3 months

~80%

45℃

<6% / month

1-2 months

~70%

Store between −5 and 35℃ in a dry, ventilated place, away from sunlight, solvents and corrosive gases; insulate the terminals, never store loose with metal parts; discharge to 30-50% SOC before long storage and top up every 3 months. Packs stored more than 12 months need a full charge/discharge and a capacity check before commissioning.

§15. Maximum Charge Current and Discharge Cut-off Voltage

Recommended charge 4.8A (0.2C), maximum 24A (1.00C); maximum continuous discharge 24A (1.00C), peak 48A (3s), BMS over-current and short-circuit protection 72A ±10A (31ms).

Discharge current

Cut-off voltage

Typical use

≤ 0.1C (≤ 2.4A)

40V

long-term standby, monitoring

0.1-0.5C (2.4-12.0A)

40V

normal cycling

0.5-1.0C (12.0-24.0A)

40V

traction, starting, inverter peaks

1.0-2.0C (24.0-48.0A)

40V

short peaks (≤3s), BMS limited

> 2.0C (> 48.0A)

—

prohibited; BMS over-current trips

Short-circuit protection: the BMS opens within 250-500μs; calculate the prospective current from the datasheet internal resistance for fuse and cable sizing.

End-of-charge: the pack is full when the CV current falls below 0.05C (about 1.2A); after termination the BMS keeps monitoring and restarts charging when a cell falls below 3.6V/cell.

§16. OEM/ODM One-Stop Customization

CHISEN SPF48V24-ST supports one-stop OEM/ODM without changing the standard electrical performance:

Case colour: ABS case in customer Pantone (standard grey-white plus red / blue / green / yellow / orange or any custom colour).

Printing and marking: customer logo silk-screen (any language), laser marking of model / serial / production date / customer code / barcode.

Packaging: standard colour box plus neutral carton; custom logo, colour, barcode and security label.

Label: battery label laid out to customer requirement, multi-language and multi-regulation.

Terminal: standard T11; other terminal forms can be tooled per project.

BMS options: optional RS485 / CAN, Bluetooth app monitoring, low-temperature heating film, dual output.

Certification and documents: CE declaration of conformity (DoC), UN38.3 test summary, MSDS and sea-transport identification supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; third-party inspection per project.

MOQ and lead time: samples from 1 unit; stock models 7-15 days, custom 30-45 days; container MOQ depends on model and packaging.

for a customised proposal and quotation, email sales@chisen.cn with model, quantity, destination market and certification requirements; reply within one business day.

§17. FAQ — High-Frequency Engineering Questions

The 18 questions industrial site engineers ask most, covering parameters, selection, installation, charging equipment, shipping and after-sales.

1. What are the charge voltage and current for SPF48V24-ST?

58.4V (16×3.65V) with 4.8A recommended (0.2C) and 24A maximum; float / standby 55.2V (16×3.45V); BMS over-charge cut-off 62.4V.

2. What is the cycle life?

≥2000 cycles @80% DoD at 25℃; one deep cycle per day gives 5+ years of design life, and shallower cycling (50% DoD) goes well beyond 2000 cycles.

3. Can it replace lead-acid directly?

Yes. Footprint, terminal positions and nominal voltage match, so the bay and wiring stay as they are; but the lead-acid charger must be set to 58.4V constant voltage with 0.2C limit, otherwise permanent under-charging fades the pack quickly (see §12).

4. Can it be connected in series or parallel?

selected directly for a 51.2V system, normally not series-connected; parallel up to 4 units, confirm BMS rating before series connection. Before connecting, cell delta must be <50mV and internal resistance deviation <15%, and all units must share model, capacity and batch.

5. Can it be charged below 0℃?

No — the BMS blocks charging below 0℃ (it can still discharge, about 65% of capacity at −20℃). For cold stores and winter sites select the LT low-temperature version or add a heating film.

6. What are the internal resistance and short-circuit current?

Internal resistance per datasheet at 1kHz, 50% SOC, 25℃; the prospective short-circuit current is about —A estimated from that resistance, quoted for fuse sizing only, not a test value.

7. What are the terminal, dimensions and weight?

T11, torque 9-11 N·m; 260×168×218 mm; 7.8kg.

8. What about operating temperature and self-discharge?

Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; self-discharge <3%/month at 25℃ and 6 months of shelf life from full charge.

9. Which standards does it meet?

IEC 62619:2022, IEC 62133-2, UN38.3 and UL 1642 (cells), designed with reference to GB 31241-2022 and GB 40165-2021. A CE declaration of conformity (DoC) and the UN38.3 test summary are supplied with every shipment; UL 1642 and IEC 62133-2 are arranged on request; shipment follows UN 3480 Class 9.

10. Can it be side-mounted or inverted?

Upright or side-mounted (terminals forward) with a maximum 90° tilt; never inverted — the seal and internal cell group do not allow it.

11. Which documents are needed for export?

Packing list, commercial invoice, CO, MSDS, UN38.3 test summary and the sea-transport identification report (UN3480, Class 9 dangerous goods, under the IMDG Code; packing group as stated on the dangerous-goods certificate); third-party inspection and destination approvals on request.

12. What are the MOQ and lead time?

Samples from 1 unit; stock models 7-15 days, OEM customisation 30-45 days; container MOQ depends on model and packaging.

13. What is the warranty?

24 months from shipment, or 2000 cycles @80% DoD / ≥80% capacity retention, whichever comes first; extended terms are negotiable and warranty letters can be issued for tenders.

14. How are price and freight quoted?

EXW factory price; sea freight quoted to destination port (FOB / CIF / DDP). Email sales@chisen.cn with quantity, destination port and certification requirements.

15. Can it be charged directly from a solar controller?

The MPPT controller must support lithium: absorption 58.4V, float 55.2V, with lead-acid equalise and temperature compensation disabled. Controllers without a lithium mode will under-charge the pack.

16. Do I need an external balancer?

No. The BMS balances passively at 57.6V (3.6V per cell); a full charge is needed periodically to trigger balancing — long periods of partial charging let cell delta grow.

17. Can old and new batteries be mixed?

No. A used unit has higher internal resistance and will be repeatedly over-charged and over-discharged in the string; replace the whole string with the same model, capacity and batch.

18. What causes a swollen battery?

Typically over-charging from a non-dedicated charger, long-term high temperature, internal short circuit or a failed BMS. Swelling is irreversible — stop using it and scrap it, never charge or discharge it again.

§18. Daily Operation and Maintenance (Engineering Guide)

Follow these seven points and SPF48V24-ST will hold 5+ years at 25℃ with one 80% DoD cycle per day:

1. Charger selection: use an industrial charger with CV/CC and temperature protection, CV point 58.4V, current limit 0.2C (4.8A); never use a lead-acid fast charger or connect straight to an alternator.

2. Installation environment: install in a cabinet or rack, ≥200mm above the floor (damp) and ≥100mm from walls (heat dissipation); ambient −20 to 60℃, no direct sun or heat source; forced ventilation in enclosed spaces.

3. Routine inspection: monthly check terminal torque (9-11 N·m) and oxidation; quarterly check cell delta (<50mV) and appearance (swelling / leakage / cracks); annual capacity check.

4. Long-term storage: discharge to 30-50% SOC, store at −5 to 35℃ dry, top up every 3 months; packs stored over 12 months need a full charge/discharge before use.

5. Troubleshooting: capacity down >20%: check the CV point and cell balance; abnormal voltage (off 51.2V by ±1.5V): top up or replace that unit; swelling / leakage / odour: stop use and isolate; frequent BMS trips: check wiring and load.

6. First use: on receipt measure open-circuit voltage (51.2-53.6V) and internal resistance after 2h rest; fully charge once before commissioning and balance strings (cell delta <20mV).

7. Safety prohibitions: never bridge both terminals with a metal tool (hundreds of amps, burns); no open flame near charging; wear goggles and insulating gloves; return scrap batteries to a licensed recycler — never dismantle, incinerate or dump.

§18b. Installation Requirements — Mandatory Delivery Checks

LiFePO4 is maintenance-free, but spacing, torque, environment and string matching directly affect safety and life. These are the mandatory delivery checks:

Item

Requirement

Note

Orientation

Upright or side-mounted (terminals forward), max 90° tilt

Never inverted — the seal and cell group do not allow it

Position

Accessible for inspection and replacement

Lowest level, to see swelling and leakage early

Spacing between units

≥10mm natural convection, do not stack tight

≥15mm inside cabinets for heat dissipation

Distance from heat sources

≥50cm

Avoid boiler, transformer and switchgear heat

Distance from wall / floor

≥100mm / ≥200mm

Bottom ventilation, damp protection

Rack load

7.8kg per unit; rack ≥3× total weight

Reinforce shelves in multi-tier racks

Terminal torque

9-11 N·m

Loose joints overheat; over-torque cracks the post

Enclosure protection

IP65 (do not immerse)

Add a rain cover outdoors

Terminal tightening torque by terminal type:

Terminal type

Torque

Applicable models

F2 push-in

tool-free, push fully home

7.2Ah / 10Ah small models

NB1 (M6 bolt)

4-5 N·m

20Ah and below (12V / 24V / 36V small models)

T11 / M8 bolt

9-11 N·m

35-300Ah main models

DIN terminal (M8)

9-11 N·m

100Ah DIN short / long case

Environmental requirements:

Item

Allowed range

Note

Ambient temperature

discharge −20 to 60℃; charge 0 to 45℃

outside the range performance and life degrade

Enclosed space

not in a fully sealed cabinet

gas accumulation during charge risks swelling

Relative humidity

≤85% RH non-condensing

high humidity corrodes terminals

Altitude

≤3000m without derating

above 3000m derate 8% per 1000m

Dust / corrosive gas

avoid salt mist, acid mist, ammonia

use a protective cabinet or coating

Vibration

avoid continuous vibration (>2g)

add damping pads on vehicles and boats

String rules (critical):

Matching: cell delta <50mV and internal resistance deviation <15% within a string.

Same batch: same model, same capacity, same batch; mixing batches causes over-charge / over-discharge of the weakest cell (weakest-cell effect).

Series / parallel: selected directly for a 51.2V system, normally not series-connected; parallel up to 4 units, confirm BMS rating before series connection.

Cables: size the cable for the continuous current (1C = 24A, 1.5× margin); short-circuit current is only for fuse selection, not cable sizing.

Wiring order: follow positive first, then negative; parallel before series; never reverse the polarity (a 102.4V difference will destroy the BMS instantly).

Before commissioning: fully charge the string for 4-8 hours to balance before commissioning and record every cell voltage.

Item

Specification

Engineering note

Connector material

tin-plated copper (≥0.3mm plating)

prevents oxidation, lowers contact resistance

Contact resistance

≤0.05mΩ per joint

joint drop dominates string losses

Tightening torque

per terminal type (table above)

loose overheats, over-tight cracks

Corrosion protection

conductive paste or heat-shrink

mandatory in salt / acid mist

§18c. Safety and Compliance — Hazard Classification and Prohibitions

LiFePO4 has good thermal stability, but high voltage, high current and thermal runaway still require strict installation and operating rules:

Level

Meaning

Typical situation

DANGER

Misuse can cause injury or death

sealed enclosure (gas accumulation), non-dedicated charger, metal tool across terminals

WARNING

May cause injury or equipment damage

uninsulated metal case, sparks or open flame, reversed polarity

CAUTION

May cause minor injury or damage

outside the specified temperature, near heat sources, immersion or damp, direct sunlight

Prohibitions:

Prohibition

Requirement

Reason

Oxidising agents

keep away from strong oxidisers

listed as incompatible in the MSDS

Mixing chemistries

never series/parallel with lead-acid, NiMH or NMC

different charge voltages and thresholds cause over-charge, leakage, fire

Organic solvents

no thinner, petrol, alcohol cleaning

corrodes the case, causes cracking and leakage

Exceeding rated current

never above the datasheet maximum

over-current heats, swells and damages the BMS

Lifting by terminals

never carry the pack by terminals or cables

damages the internal group and seal

Stepping / heavy loads

do not step on or stack heavy items

case deformation, internal short circuit

Disassembly

do not open the case or replace the BMS

high voltage and electrolyte risk, warranty void

Restricted applications (high-reliability):

Application

Requirement

Note

Life-support medical

requires an independent backup system

battery failure can endanger life

Dialysis equipment

not recommended

high-reliability requirement, professional assessment

Nuclear / defence

prohibited

requires a dedicated non-commercial scheme

Automotive / aviation / rail / marine control

prohibited (auxiliary power excepted)

moving-platform vibration and failure consequences

Subsea equipment

prohibited

high pressure and humidity, leakage consequences

Work protection and disposal:

Item

Requirement

Note

Insulated tools

tape-wrapped wrench, one terminal at a time

prevents bridging the terminals

PPE

insulating gloves, goggles, insulated boots

shock, burn and electrolyte splash

Electrolyte contact

flush skin or eyes with plenty of water for at least 15 minutes and seek medical help

LiPF6 hydrolyses to HF, corrosive

Scrap disposal

return to a licensed recycler; never dismantle, incinerate or dump in water

lithium, iron, copper and aluminium are recoverable

Emergency handling:

Symptom

Immediate action

Note

Swelling / deformation

stop use and isolate

precursor to thermal runaway

Leakage / odour

power off, ventilate, evacuate

corrosive electrolyte plus flammable gas

Abnormal heat

stop charging, disconnect load

check charger and wiring for short or reverse connection

Abnormal cell voltage

balance the string, handle the weak cell separately

>50mV deviation needs matching

Fire

cool with copious cold water, or smother with dry powder, sand or earth; never use Halon

burning evolves CO, CO2, HF and phosphorus fluorides

This section follows mainstream LiFePO4 industrial safety practice for export project compliance review; site procedures, local regulations (e.g. NFPA 70E, IEC 62485) and contract terms take precedence. For life-safety applications have the design reviewed by a licensed electrical engineer.

§19. CHISEN Product Strength and Global Service System

Why choose CHISEN:

1. Product range: 20+ years in battery R&D and manufacturing, covering VRLA lead-acid, LiFePO4 modules, BMS and energy storage systems; ST / LT / BL / LB series across 12V / 24V / 36V / 48V, 7Ah to 300Ah, mainstream models in stock, bulk lead time typically 7-15 days subject to order confirmation.

2. Global service network: 60+ export countries (China / Southeast Asia / Europe / Africa / Middle East / Latin America / Central Asia / Oceania) with telecom, power, data centre, PV, RV-marine and medical project experience; multilingual technical documents and support (EN / CN / ES / FR / AR / RU).

3. Quality control: voltage and internal resistance checked on every unit before shipment, capacity and appearance sampled per batch; SPC on key processes (cell grading, BMS test, assembly, sealing); third-party inspection can be arranged.

4. Export support: CE declaration of conformity and first-hand customs documents (invoice / packing list / CO / MSDS / UN38.3 / sea-transport identification / factory test report); multilingual technical documents (EN / CN / ES / FR / AR / RU); destination approvals handled on request.

5. Long-term cooperation: dedicated technical contact for long-term customers; OEM partners can share sales leads and training; rebates, priority supply and new-product trials are set out in the agreement.

6. Sustainability: LiFePO4 is recyclable for lithium, iron, copper and aluminium; RoHS / REACH related declarations per test results; destination environmental and market-access requirements handled per customer need.

§20. Contact — Reply within 1 Business Day

CHISEN — 20+ years focused on batteries, exporting to 60+ countries.

Email: sales@chisen.cn (quotation and sizing proposal within one business day)

Tel / WhatsApp: +86 131 6622 6999

Website: https://www.chisen.cn

Location: production base: Guangdong province (LiFePO4 modules and BMS assembly); sales and technical support: Hangzhou, Zhejiang.

Note: figures on this page are taken from the current datasheet for selection reference. Specifications may change without notice; the contract and the datasheet shipped with the goods prevail. Certificates, test reports and destination approvals are provided per model.