CHISEN SPF24V40-ST 25.6V 40Ah LiFePO4 Battery | Lead-Acid Replacement / Maintenance-Free | OEM Factory Direct
30-Second Overview of CHISEN SPF24V40-ST
Model: SPF24V40-ST (25.6V 40Ah / 1024Wh, 8 LiFePO4 cells in series)
Technology: LiFePO4 cells + integrated BMS (over-charge / over-discharge / over-current / short circuit / temperature protection) + ABS case (IP65) + copper-core terminals
Highlights: ≥2000 cycles @80% DoD (4-6× lead-acid); 9.4kg pack, about 40% of the lead-acid weight; maintenance-free; 2 in series for a 48V system
Typical use: AGV / AMR, Wheelchairs, RV 24V system, Marine 24V
§1. Product Definition and Four Core Advantages
CHISEN SPF24V40-ST is a 25.6V 40Ah (1024Wh) LiFePO4 battery with 8 cells in series and an integrated BMS, packaged in a 24 group case with the same footprint and terminal positions as the equivalent lead-acid / AGM / GEL battery, so the battery bay, hold-down and wiring need no change.
The ST series fits both motive and storage duty — electric vehicles, energy storage systems, defense and security, telecom outdoor, renewable energy and other harsh environments. For storage, size the capacity by backup time and daily energy; for motive duty, by continuous / peak current and range.
Configuration: 8S × 3.2V = 25.6V, 40Ah, 1024Wh; the BMS does cell-voltage sensing, passive balancing (balance point 28.8V) and over-charge / over-discharge / over-current / short-circuit / high-low temperature protection, with common charge-discharge port.
Charge / discharge: recommended CC/CV with 29.2V (8×3.65V) and 8A (0.2C), 40A maximum; max continuous discharge 50A (1.25C), peak 100A (3s), BMS cut-off 20V (8×2.5V).
Applications: AGV / AMR, Wheelchairs, RV 24V system, Marine 24V, Solar street lights.
CHISEN has focused on batteries for 20+ years, exporting to 60+ countries and supplying OEM/ODM customers in telecom, power, data centre, PV, RV/marine and medical-equipment sectors with cell, BMS and pack-level solutions.
Four core advantages:
1. 2000 deep cycles, about 4-6× lead-acid by cycle count: at one 80% DoD cycle per day, 2000 cycles is 5+ years of design life; lead-acid at the same duty (50% DoD, 300-500 cycles) needs a full replacement after 1 to 1.5 years. LiFePO4 does not sulphate when deep-discharged, so capacity fades gradually instead of dropping abruptly.
2. Lightweight: 9.4kg per pack against ~25.6kg for the same lead-acid capacity, about 63% lighter — easier handling, less ballast in the boat, more payload for AGVs and golf carts.
3. Maintenance-free, no water, no acid mist: sealed maintenance-free construction: no watering, no equalise charge, no acid mist and no sulphation; IP65 case, side mounting allowed (terminals forward) for tight RV, locker and cabinet spaces.
4. Five-fold BMS protection: over-charge cut at 31.2V, over-discharge cut at 20V, 150A over-current and short-circuit protection (250-500μs), 65℃ high-temperature cut-off and no charging below 0℃; the BMS disconnects and auto-recovers, preventing swelling and thermal runaway.
Also: round-trip efficiency ≥95% (typical) versus 70-85% for lead-acid, self-discharge <3%/month and 6+ months of shelf life at full charge, so the same PV array and charger put about 10-20% more energy into the battery.
§2. Key Specifications
Quick-reference specification for this model (full standards list in §4, series table in §6, charge and protection thresholds in §12 and §15).
|
Parameter |
Value |
|---|---|
|
Model |
SPF24V40-ST |
|
Series |
ST Standard Type |
|
Nominal voltage |
25.6V |
|
Nominal capacity |
40Ah (10-hour rate) |
|
Energy |
1024Wh |
|
Cell configuration |
LiFePO4, 8 cells in series |
|
Case / terminal style |
24 group case |
|
Max continuous discharge |
50A (1.25C) |
|
Peak discharge current |
100A (3s) |
|
BMS discharge cut-off current |
150A ±10A (31ms) |
|
Recommended charge voltage |
29.2V (8×3.65V) |
|
Float / standby voltage |
27.6V (8×3.45V) |
|
BMS over-charge protection |
31.2V (8×3.9V) |
|
Balancing voltage |
28.8V (8×3.6V) |
|
Recommended charge current |
8A (0.2C) |
|
Max charge current |
40A (1.00C) |
|
Discharge cut-off voltage |
20V (8×2.5V) |
|
Recommended low-voltage disconnect |
22V (8×2.75V) |
|
Internal resistance (1kHz, 50% SOC, 25℃) |
per datasheet |
|
Dimensions L×W×H |
260×168×218 mm |
|
Weight |
9.4kg (±2%) |
|
Terminal |
T11 |
|
Terminal torque |
9-11 N·m |
|
Case material |
ABS engineering plastic |
|
Enclosure protection |
IP65 |
|
Self-discharge |
<3% / month (25℃) |
|
Cycle life |
≥2000 cycles @80% DoD (25℃) |
|
Charge temperature |
0 to 45℃ |
|
Discharge temperature |
−20 to 60℃ |
|
Storage temperature |
−5 to 35℃ |
|
Certification & documents |
CE declaration of conformity (DoC) and UN38.3 test summary supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; MSDS and sea-transport identification report included |
|
Shipping classification |
UN 3480, Class 9 |
Note: charge and protection thresholds are calculated from the 8-cell series design (3.65V / 3.9V charge and over-charge, 3.45V float, 3.6V balance, 2.5V / 2.75V discharge and LVD). Values marked * are design values. Test reports for the exact model are available on request.
§3. Model Nomenclature — Field Breakdown
CHISEN ST series uses a segmented code (series + voltage class + capacity + type + case), so a model can be selected from the system voltage and the available space alone.
|
Field |
Meaning |
This model |
|---|---|---|
|
SPF |
Product series |
SPF = LiFePO4 battery module |
|
25.6V |
Voltage class |
25.6V = 8 cells × 3.2V |
|
40 |
Rated capacity |
40Ah at the 10-hour rate |
|
-ST |
Product type |
ST = Standard Type (also LT low-temperature, BL Bluetooth, LB low-temp Bluetooth) |
|
24 group case |
Case / terminal variant |
24 group case |
SPF24V40-ST = SPF series + 25.6V class (8S) + 40Ah + ST standard type, 24 group case.
§4. Applicable International / Regional / Chinese Standards
The standards below are referenced for design, procurement and tender documentation.
|
Standard |
Title |
Type |
Adoption |
Use |
|---|---|---|---|---|
|
IEC 62619:2022 |
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for secondary lithium cells and batteries for industrial applications |
International |
Safety design basis |
Export / industrial ESS |
|
IEC 62133-2:2017 |
Secondary sealed cells and batteries — Safety requirements for portable lithium systems |
International |
Cell and pack safety |
Export / customer acceptance |
|
UN38.3 |
UN Manual of Tests and Criteria, section 38.3 — transport safety testing |
International |
Transport testing |
Air / sea / courier |
|
UL 1642 |
Standard for safety — Lithium batteries (cells) |
USA |
Cell safety |
North America |
|
GB 31241-2022 |
Lithium-ion cells and batteries for portable electronic equipment — safety technical specification |
China |
Design reference |
Domestic sales / tenders |
|
GB 40165-2021 |
Lithium-ion cells and batteries for stationary electronic equipment — safety technical specification |
China |
Design reference |
Domestic ESS / tenders |
|
UN 3480 Class 9 |
UN Model Regulations — lithium-ion batteries (standalone) |
International |
Transport classification |
Booking / customs |
Note: third-party test reports and destination approvals (e.g. EU Battery Regulation, UL 2054 pack certification) are handled per project; standards are listed for design and procurement reference.
§5. Physical Construction and Materials (LiFePO4 cells + BMS)
Construction of CHISEN SPF24V40-ST:
Cells: prismatic aluminium-shell or cylindrical steel-shell LiFePO4 cells; the olivine LiFePO4 cathode is structurally stable and does not release oxygen, which is the root of the safety margin.
Anode and electrolyte: graphite anode with LiPF6 organic electrolyte and a polyethylene (PE) separator; cells are graded for capacity, voltage and internal resistance, matching within 20mV per group.
BMS: over-charge, over-discharge, over-current, short-circuit, high/low temperature protection and passive balancing, common port; cell sensing ±25mV, balancing starts at 28.8V and closes within 20mV.
five-fold protection thresholds (per 8 cells in series):
|
Protection |
Trigger |
Recovery |
Action time |
|---|---|---|---|
|
Over-charge |
cell ≥3.9V (pack 31.2V) |
auto-recover when back to 3.6V/cell (28.8V) |
instant |
|
Over-discharge |
cell ≤2.5V (pack 20V) |
recover after charging above 2.8V/cell |
instant |
|
Over-current |
≥150A ±10A |
auto-recover after load removal |
31ms |
|
Short circuit |
output shorted |
auto-recover after fault cleared |
250-500μs |
|
High temperature |
≥65℃ |
recover below 55℃ |
instant |
|
Low temperature |
charging ≤0℃ |
recover above 5℃ |
instant |
Case and sealing: ABS engineering plastic, 24 group case, IP65; double sealing between case and lid (structural adhesive + gasket) and an O-ring at the terminal keep moisture out.
Marking: model and capacity are silk-screened or laser-marked on the front, with model, voltage, capacity, energy, production batch and warning marks.
Structural difference vs lead-acid: lead-acid (AGM / GEL) delivers 300-500 cycles to 80% capacity at 50% DoD and still needs equalise charging and terminal inspection; LiFePO4 delivers 2000+ cycles at 80% DoD with no maintenance. In the same space the usable energy is about 1.6× (80% vs 50% DoD), which is the direct value of lead-acid replacement.
Replacement warning: a lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, while this model needs 29.2V constant voltage. Keeping the lead-acid charger leaves the pack permanently under-charged, which fades capacity and defeats balancing — switch the charger to lithium mode or replace it (see §12).
§6. ST Series 25.6V Full Capacity Table (9 models)
The 25.6V platform of the ST series has 9 capacity models (LiFePO4, 8S). Models in the same voltage class are drop-in interchangeable by capacity and can be connected in series for higher system voltages.
|
No. |
Model |
V |
Ah |
Max A |
Size mm |
kg |
Terminal |
Case / BCI |
|---|---|---|---|---|---|---|---|---|
|
1 |
SPF24V10-ST |
25.6 |
10 |
15 |
181×76×166 |
2.8 |
NB1 |
NB1 case |
|
2 |
SPF24V20-ST |
25.6 |
20 |
20 |
198×166×171 |
5.8 |
T11 |
166 standard case |
|
3 |
SPF24V30-ST |
25.6 |
30 |
30 |
229×138×222 |
7.2 |
T11 |
30 group case |
|
4 |
SPF24V40-ST |
25.6 |
40 |
50 |
260×168×218 |
9.4 |
T11 |
24 group case |
|
5 |
SPF24V50-ST |
25.6 |
50 |
50 |
329×172×223 |
12.6 |
T11 |
31 group case |
|
6 |
SPF24V60-ST |
25.6 |
60 |
60 |
329×172×223 |
14.5 |
T11 |
31 group case |
|
7 |
SPF24V100-ST-8D |
25.6 |
100 |
100 |
520×268×228 |
25.8 |
T11 |
8D case |
|
8 |
SPF24V100-ST-C |
25.6 |
100 |
100 |
484×170×241 |
24.8 |
T11 |
compact case |
|
9 |
SPF24V140-ST-8D |
25.6 |
140 |
140 |
520×268×228 |
34.2 |
T11 |
8D case |
This page covers SPF24V40-ST, highlighted above: 40Ah / 1024Wh / 9.4kg.
Other voltage classes in the same series:
|
Class |
Series |
Models |
Capacity range |
Max discharge |
Typical use |
|---|---|---|---|---|---|
|
12V |
4S |
20 |
7.2-300Ah |
15-150A |
RV, marine, off-grid solar, telecom/CCTV, mobility and scrubbers |
|
24V |
8S |
9 |
10-140Ah |
15-140A |
AGV, wheelchairs, marine, RV, solar street lights |
|
36V |
12S |
6 |
7-96Ah |
10-100A |
Golf carts, tricycles, scrubbers, stackers, garden machinery |
|
48V |
16S |
5 |
12-72Ah |
20-72A |
Telecom sites, home ESS, golf carts, forklifts, edge data centres |
Note: do not mix capacities or batches in one string — every unit in a string must be the same model, capacity and batch (see §18b).
§7. Main Applications and Reference Cases
CHISEN SPF24V40-ST serves the following 5 applications (this model: 40Ah / 1024Wh, about 819Wh usable at 80% DoD):
AGV / AMR: 24V platform for warehouse robots; 1C covers acceleration and lift.
Wheelchairs: Light, deep-cycle; more range than the same lead-acid capacity.
RV 24V system: Matches 24V inverters and solar controllers directly.
Marine 24V: Propulsion and house loads; sealed case resists salt mist.
Solar street lights: Charge by day, discharge at night; maintenance-free for pole-top mounting.
Every figure below is derived from this model's own capacity (DoD 0.8, inverter 0.9):
Case 1: Lighting / monitoring (sized from this model)
40Ah (1024Wh) drives a 125W load for about 6 hours at DoD 0.8 and 0.9 inverter efficiency; at 62W the runtime doubles to about 12 hours.
Case 2: Monitoring / telecom backup (sized from this model)
for a 4-hour backup the same pack supports 185W (1024Wh × 0.8 × 0.9 ÷ 4).
Case 3: Daily cycling (sized from this model)
one 80% DoD cycle per day gives 819Wh per day, about 298935Wh per year; 2000 cycles is roughly 5 years.
Case 4: Lead-acid replacement (sized from this model)
the same lead-acid capacity offers about 512Wh usable (50% DoD) against 819Wh here (80% DoD), 60% more energy, at 9.4kg versus about 25.6kg — about 63% lighter.
Case 5: String expansion (sized from this model)
2 in series gives a 51.2V / 2048Wh pack at 40Ah; up to 4 parallel strings, maximum 160Ah / 8192Wh.
§8. ST Series vs Lead-Acid / AGM / GEL — Full Comparison
Same footprint and nominal voltage, LiFePO4 against lead-acid (AGM / GEL):
|
Item |
This series (LiFePO4 ST) |
Lead-acid AGM / GEL |
Conclusion |
|---|---|---|---|
|
Energy density |
~109 Wh/kg |
~30-40 Wh/kg |
2-3× the energy per kg |
|
Cycle life |
≥2000 @80% DoD |
300-500 @50% DoD |
4-6× lead-acid |
|
Usable capacity |
80-90% DoD |
50% DoD (deeper cycles shorten life) |
60% more usable energy |
|
Round-trip efficiency |
≥95% |
70-85% |
10-20% more from the same PV array |
|
Self-discharge |
<3% / month |
3-5% / month, plus sulphation |
6+ months of shelf life |
|
Weight |
9.4kg |
~25.6kg |
about 63% lighter |
|
Maintenance |
none |
watering, equalise charge, corrosion checks |
near-zero O&M |
|
Continuous rate |
1.25C (peak 2.5C) |
0.2-0.3C |
no sag on starts |
|
Low-temperature discharge |
~65% at −20℃ (typical) |
~50% at −20℃ |
better for cold stores and winter |
|
Mounting |
any orientation except inverted |
upright only |
fits lockers and cabinets |
|
Environment |
no lead-acid electrolyte, fully recyclable |
lead and sulphuric acid, higher disposal requirements |
simpler recycling |
|
Replacements in 10 years |
1-2 |
4-6 |
lower total cost of ownership |
§9. Selection Decision Table
Fit of this model (40Ah / 25.6V) in each application; "suitable in combination" means several units in series or parallel are needed.
|
Application |
Fit for this model |
Note |
|---|---|---|
|
Monitoring / lighting / access control |
Suitable |
40Ah is enough |
|
RV / camper house power |
Suitable in combination |
75Ah and above recommended; this model is 40Ah |
|
Marine power / house |
Not suitable |
≥1C for starting; 100Ah and above |
|
Residential off-grid solar |
Suitable in combination |
size from night consumption ÷ 0.8 DoD |
|
Telecom / CCTV backup |
Suitable |
4-10 hour backup |
|
Telecom site 48V |
Not suitable |
direct at 48V; string other classes |
|
Golf cart / e-tricycle |
Not suitable |
direct at 36V / 48V; 3-4 in series from 12V |
|
AGV / forklift |
Suitable |
direct at 24V / 48V; string other classes |
§10. Capacity Sizing Formula and Configuration Examples
Capacity (Ah) = load (W) × backup time (h) ÷ system voltage (V) ÷ inverter efficiency ÷ depth of discharge ÷ temperature factor
Assumptions: inverter efficiency 0.85 (low-frequency) / 0.90 (high-frequency) / 1.0 (DC loads).
DoD and temperature: LiFePO4 allows 0.80-0.90 (lead-acid only 0.50); temperature factor 1.0 at 25℃, 0.90 at 0℃, 0.75 at −10℃, 0.65 at −20℃, 0.95 at 45℃; keep 20-30% ageing margin.
Sizing example 1 (25.6V system): off-grid lighting load 120W for 8h per day, inverter 0.9, DoD 0.8 → 120×8÷25.6÷0.9÷0.8 ≈ 52.1Ah — select 40Ah × 2 in parallel (80Ah total).
Pack example 2 (2 in series = 51.2V / 2048Wh pack): at DoD 0.8 and inverter 0.9 it supports 350W for about 4.2 hours (2048×0.8×0.9÷350); at 175W the runtime doubles to about 8.4 hours.
constant-current discharge capability (25℃, typical, varies with temperature and load):
|
Discharge time |
Current |
Usable capacity |
Power at 25.6V |
|---|---|---|---|
|
20 HR |
2.0 A |
40 Ah |
~51 W |
|
10 HR |
4.0 A |
40 Ah |
~102 W |
|
5 HR |
8.0 A |
40 Ah |
~205 W |
|
3 HR |
13.3 A |
39 Ah |
~335 W |
|
1 HR |
40.0 A |
38 Ah |
~973 W |
Rule of thumb: short high-current duty (UPS 30min class) needs a high-rate model, checked against the current table in §15; long low-current duty (telecom 4-10h) uses the 10HR row.
charger compatibility is where lead-acid replacements most often go wrong:
|
Charger type |
Directly usable? |
Setting |
|---|---|---|
|
Lithium charger |
Directly usable |
29.2V constant voltage, current ≤8A (0.2C) |
|
Existing lead-acid charger |
Not directly |
Switch to lithium mode (29.2V CV) or replace; temperature compensation must be off |
|
MPPT solar controller |
Must support lithium |
Absorption 29.2V, float 27.6V; disable lead-acid equalise and temp compensation |
|
Vehicle DC-DC / alternator |
Must limit voltage |
Output must not exceed 31.2V or the BMS over-charge protection trips |
|
Inverter-charger |
Usable |
Select LiFePO4 / 4S mode, charge current 0.2C |
§11. Cycle Life and Total Cost of Ownership (TCO)
Cycle life is ≥2000 cycles @80% DoD (25℃); cells still hold above 80% capacity after 2000 cycles at 1C charge/discharge, and a pack cycled at the usual 0.2C typically exceeds the rating.
TCO = purchase cost + replacements × purchase cost + maintenance + downtime loss − residual value
|
Item |
LiFePO4 (this series) |
Lead-acid AGM / GEL |
|---|---|---|
|
Cycle life |
2000 @80% DoD |
350 @50% DoD |
|
10-year cycles (one per day) |
3650 |
3650 |
|
Packs needed over 10 years |
2 |
11 |
|
Purchase cost index (example) |
1.0 |
0.45 per pack |
|
10-year purchase index |
2.0 |
4.9 |
|
Maintenance |
none |
watering, equalise, corrosion checks |
|
Downtime replacements |
1 |
10 |
|
Cost per cycle |
low |
high |
Note: the cost index is an illustrative assumption used only to show the replacement-count difference; request a quotation for actual project pricing.
§12. Charge Voltage Setting and Temperature Relationship
Standard charge is 29.2V (8×3.65V) CC/CV at 8A (0.2C), 40A maximum; float / standby is 27.6V (8×3.45V).
|
Stage |
Voltage (25℃) |
Current |
Termination |
|---|---|---|---|
|
Constant current (CC) |
raise to 29.2V |
8A (0.2C) |
reaches 29.2V |
|
Constant voltage (CV) |
29.2V |
tapering |
current falls to 0.05C (~2.0A) |
|
Float / standby |
27.6V |
≤0.02C |
continuous |
|
Balancing |
28.8V |
passive |
cell delta <20mV |
Charging strategy by temperature:
|
Temperature |
Allowed current |
Charge voltage |
Note |
|---|---|---|---|
|
< 0℃ |
charging prohibited |
— |
BMS blocks the charge path; cold stores and winter sites need heating or the LT version |
|
0-10℃ |
0.1C limit |
29.2V |
low-temperature charge acceptance is reduced |
|
10-25℃ |
0.2C |
29.2V |
optimum window |
|
25-40℃ |
0.2-0.3C |
29.2V |
ensure ventilation |
|
40-45℃ |
0.1C derated |
29.2V |
no charging above 45℃ |
|
> 45℃ |
charging prohibited |
— |
BMS high-temperature protection |
LiFePO4 does not need the lead-acid (-3mV/℃/cell) temperature compensation; the BMS handles the cell thresholds, so the charger only has to hold the CV point accurately.
Replacement point: this is the step where lead-acid replacements fail most often. A lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, both below what this model needs, so the pack is permanently under-charged, cells drift apart and capacity fades quickly. Set the charger to 29.2V CV with 0.2C current limit, or replace it with a lithium charger; disable any temperature compensation.
§13. Operating Temperature Range (discharge / charge / storage)
Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; optimum 25℃ (the capacity reference point). The BMS cuts at 65℃ and recovers at 55℃.
|
Temperature |
Usable capacity (typical) |
Charging |
Note |
|---|---|---|---|
|
60℃ (discharge limit) |
~95% |
prohibited |
derated; forced ventilation required |
|
40℃ |
~100% |
0.1C derated |
avoid direct sunlight, improve cooling |
|
25℃ (reference) |
100% |
0.2C |
best balance of capacity and life |
|
0℃ |
~90% |
0.1C limit |
lower charge acceptance |
|
−10℃ |
~75% |
prohibited |
pre-heat above 0℃ before charging |
|
−20℃ (discharge limit) |
~65% |
prohibited |
discharge only, BMS low-temperature protection |
Note: capacity varies with rate and temperature; figures are typical at 0.2C. At −20℃ LiFePO4 still delivers about 65% while lead-acid delivers about 50%, which matters for cold stores and high-altitude projects.
heat accelerates ageing: above 25℃ every 10℃ rise roughly halves cycle life, so for continuous duty above 45℃ improve ventilation, lower the charge voltage ceiling or select a high-temperature derated option.
§14. Self-Discharge Rate and Storage Conditions
Self-discharge is below 3%/month at 25℃ from full charge, so a fully charged pack still starts after 6 months; for long storage keep 30-50% SOC and top up every 3 months.
|
Storage temperature |
Self-discharge |
Recharge interval |
Remaining capacity |
|---|---|---|---|
|
20℃ |
<1.5% / month |
12 months |
~90% |
|
25℃ |
<3% / month |
6 months |
~85% |
|
35℃ |
<4% / month |
3 months |
~80% |
|
45℃ |
<6% / month |
1-2 months |
~70% |
Store between −5 and 35℃ in a dry, ventilated place, away from sunlight, solvents and corrosive gases; insulate the terminals, never store loose with metal parts; discharge to 30-50% SOC before long storage and top up every 3 months. Packs stored more than 12 months need a full charge/discharge and a capacity check before commissioning.
§15. Maximum Charge Current and Discharge Cut-off Voltage
Recommended charge 8A (0.2C), maximum 40A (1.00C); maximum continuous discharge 50A (1.25C), peak 100A (3s), BMS over-current and short-circuit protection 150A ±10A (31ms).
|
Discharge current |
Cut-off voltage |
Typical use |
|---|---|---|
|
≤ 0.1C (≤ 4.0A) |
20V |
long-term standby, monitoring |
|
0.1-0.5C (4.0-20.0A) |
20V |
normal cycling |
|
0.5-1.0C (20.0-40.0A) |
20V |
traction, starting, inverter peaks |
|
1.0-2.0C (40.0-80.0A) |
20V |
short peaks (≤3s), BMS limited |
|
> 2.0C (> 80.0A) |
— |
prohibited; BMS over-current trips |
Short-circuit protection: the BMS opens within 250-500μs; calculate the prospective current from the datasheet internal resistance for fuse and cable sizing.
End-of-charge: the pack is full when the CV current falls below 0.05C (about 2.0A); after termination the BMS keeps monitoring and restarts charging when a cell falls below 3.6V/cell.
§16. OEM/ODM One-Stop Customization
CHISEN SPF24V40-ST supports one-stop OEM/ODM without changing the standard electrical performance:
Case colour: ABS case in customer Pantone (standard grey-white plus red / blue / green / yellow / orange or any custom colour).
Printing and marking: customer logo silk-screen (any language), laser marking of model / serial / production date / customer code / barcode.
Packaging: standard colour box plus neutral carton; custom logo, colour, barcode and security label.
Label: battery label laid out to customer requirement, multi-language and multi-regulation.
Terminal: standard T11; other terminal forms can be tooled per project.
BMS options: optional RS485 / CAN, Bluetooth app monitoring, low-temperature heating film, dual output.
Certification and documents: CE declaration of conformity (DoC), UN38.3 test summary, MSDS and sea-transport identification supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; third-party inspection per project.
MOQ and lead time: samples from 1 unit; stock models 7-15 days, custom 30-45 days; container MOQ depends on model and packaging.
for a customised proposal and quotation, email sales@chisen.cn with model, quantity, destination market and certification requirements; reply within one business day.
§17. FAQ — High-Frequency Engineering Questions
The 18 questions industrial site engineers ask most, covering parameters, selection, installation, charging equipment, shipping and after-sales.
1. What are the charge voltage and current for SPF24V40-ST?
29.2V (8×3.65V) with 8A recommended (0.2C) and 40A maximum; float / standby 27.6V (8×3.45V); BMS over-charge cut-off 31.2V.
2. What is the cycle life?
≥2000 cycles @80% DoD at 25℃; one deep cycle per day gives 5+ years of design life, and shallower cycling (50% DoD) goes well beyond 2000 cycles.
3. Can it replace lead-acid directly?
Yes. Footprint, terminal positions and nominal voltage match, so the bay and wiring stay as they are; but the lead-acid charger must be set to 29.2V constant voltage with 0.2C limit, otherwise permanent under-charging fades the pack quickly (see §12).
4. Can it be connected in series or parallel?
up to 2 in series is recommended (25.6V→51.2V for a 48V system); parallel up to 4 units; confirm BMS voltage rating before going higher. Before connecting, cell delta must be <50mV and internal resistance deviation <15%, and all units must share model, capacity and batch.
5. Can it be charged below 0℃?
No — the BMS blocks charging below 0℃ (it can still discharge, about 65% of capacity at −20℃). For cold stores and winter sites select the LT low-temperature version or add a heating film.
6. What are the internal resistance and short-circuit current?
Internal resistance per datasheet at 1kHz, 50% SOC, 25℃; the prospective short-circuit current is about —A estimated from that resistance, quoted for fuse sizing only, not a test value.
7. What are the terminal, dimensions and weight?
T11, torque 9-11 N·m; 260×168×218 mm; 9.4kg.
8. What about operating temperature and self-discharge?
Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; self-discharge <3%/month at 25℃ and 6 months of shelf life from full charge.
9. Which standards does it meet?
IEC 62619:2022, IEC 62133-2, UN38.3 and UL 1642 (cells), designed with reference to GB 31241-2022 and GB 40165-2021. A CE declaration of conformity (DoC) and the UN38.3 test summary are supplied with every shipment; UL 1642 and IEC 62133-2 are arranged on request; shipment follows UN 3480 Class 9.
10. Can it be side-mounted or inverted?
Upright or side-mounted (terminals forward) with a maximum 90° tilt; never inverted — the seal and internal cell group do not allow it.
11. Which documents are needed for export?
Packing list, commercial invoice, CO, MSDS, UN38.3 test summary and the sea-transport identification report (UN3480, Class 9 dangerous goods, under the IMDG Code; packing group as stated on the dangerous-goods certificate); third-party inspection and destination approvals on request.
12. What are the MOQ and lead time?
Samples from 1 unit; stock models 7-15 days, OEM customisation 30-45 days; container MOQ depends on model and packaging.
13. What is the warranty?
24 months from shipment, or 2000 cycles @80% DoD / ≥80% capacity retention, whichever comes first; extended terms are negotiable and warranty letters can be issued for tenders.
14. How are price and freight quoted?
EXW factory price; sea freight quoted to destination port (FOB / CIF / DDP). Email sales@chisen.cn with quantity, destination port and certification requirements.
15. Can it be charged directly from a solar controller?
The MPPT controller must support lithium: absorption 29.2V, float 27.6V, with lead-acid equalise and temperature compensation disabled. Controllers without a lithium mode will under-charge the pack.
16. Do I need an external balancer?
No. The BMS balances passively at 28.8V (3.6V per cell); a full charge is needed periodically to trigger balancing — long periods of partial charging let cell delta grow.
17. Can old and new batteries be mixed?
No. A used unit has higher internal resistance and will be repeatedly over-charged and over-discharged in the string; replace the whole string with the same model, capacity and batch.
18. What causes a swollen battery?
Typically over-charging from a non-dedicated charger, long-term high temperature, internal short circuit or a failed BMS. Swelling is irreversible — stop using it and scrap it, never charge or discharge it again.
§18. Daily Operation and Maintenance (Engineering Guide)
Follow these seven points and SPF24V40-ST will hold 5+ years at 25℃ with one 80% DoD cycle per day:
1. Charger selection: use an industrial charger with CV/CC and temperature protection, CV point 29.2V, current limit 0.2C (8A); never use a lead-acid fast charger or connect straight to an alternator.
2. Installation environment: install in a cabinet or rack, ≥200mm above the floor (damp) and ≥100mm from walls (heat dissipation); ambient −20 to 60℃, no direct sun or heat source; forced ventilation in enclosed spaces.
3. Routine inspection: monthly check terminal torque (9-11 N·m) and oxidation; quarterly check cell delta (<50mV) and appearance (swelling / leakage / cracks); annual capacity check.
4. Long-term storage: discharge to 30-50% SOC, store at −5 to 35℃ dry, top up every 3 months; packs stored over 12 months need a full charge/discharge before use.
5. Troubleshooting: capacity down >20%: check the CV point and cell balance; abnormal voltage (off 25.6V by ±1.5V): top up or replace that unit; swelling / leakage / odour: stop use and isolate; frequent BMS trips: check wiring and load.
6. First use: on receipt measure open-circuit voltage (25.6-26.8V) and internal resistance after 2h rest; fully charge once before commissioning and balance strings (cell delta <20mV).
7. Safety prohibitions: never bridge both terminals with a metal tool (hundreds of amps, burns); no open flame near charging; wear goggles and insulating gloves; return scrap batteries to a licensed recycler — never dismantle, incinerate or dump.
§18b. Installation Requirements — Mandatory Delivery Checks
LiFePO4 is maintenance-free, but spacing, torque, environment and string matching directly affect safety and life. These are the mandatory delivery checks:
|
Item |
Requirement |
Note |
|---|---|---|
|
Orientation |
Upright or side-mounted (terminals forward), max 90° tilt |
Never inverted — the seal and cell group do not allow it |
|
Position |
Accessible for inspection and replacement |
Lowest level, to see swelling and leakage early |
|
Spacing between units |
≥10mm natural convection, do not stack tight |
≥15mm inside cabinets for heat dissipation |
|
Distance from heat sources |
≥50cm |
Avoid boiler, transformer and switchgear heat |
|
Distance from wall / floor |
≥100mm / ≥200mm |
Bottom ventilation, damp protection |
|
Rack load |
9.4kg per unit; rack ≥3× total weight |
Reinforce shelves in multi-tier racks |
|
Terminal torque |
9-11 N·m |
Loose joints overheat; over-torque cracks the post |
|
Enclosure protection |
IP65 (do not immerse) |
Add a rain cover outdoors |
Terminal tightening torque by terminal type:
|
Terminal type |
Torque |
Applicable models |
|---|---|---|
|
F2 push-in |
tool-free, push fully home |
7.2Ah / 10Ah small models |
|
NB1 (M6 bolt) |
4-5 N·m |
20Ah and below (12V / 24V / 36V small models) |
|
T11 / M8 bolt |
9-11 N·m |
35-300Ah main models |
|
DIN terminal (M8) |
9-11 N·m |
100Ah DIN short / long case |
Environmental requirements:
|
Item |
Allowed range |
Note |
|---|---|---|
|
Ambient temperature |
discharge −20 to 60℃; charge 0 to 45℃ |
outside the range performance and life degrade |
|
Enclosed space |
not in a fully sealed cabinet |
gas accumulation during charge risks swelling |
|
Relative humidity |
≤85% RH non-condensing |
high humidity corrodes terminals |
|
Altitude |
≤3000m without derating |
above 3000m derate 8% per 1000m |
|
Dust / corrosive gas |
avoid salt mist, acid mist, ammonia |
use a protective cabinet or coating |
|
Vibration |
avoid continuous vibration (>2g) |
add damping pads on vehicles and boats |
String rules (critical):
Matching: cell delta <50mV and internal resistance deviation <15% within a string.
Same batch: same model, same capacity, same batch; mixing batches causes over-charge / over-discharge of the weakest cell (weakest-cell effect).
Series / parallel: up to 2 in series is recommended (25.6V→51.2V for a 48V system); parallel up to 4 units; confirm BMS voltage rating before going higher.
Cables: size the cable for the continuous current (1C = 40A, 1.5× margin); short-circuit current is only for fuse selection, not cable sizing.
Wiring order: follow positive first, then negative; parallel before series; never reverse the polarity (a 51.2V difference will destroy the BMS instantly).
Before commissioning: fully charge the string for 4-8 hours to balance before commissioning and record every cell voltage.
|
Item |
Specification |
Engineering note |
|---|---|---|
|
Connector material |
tin-plated copper (≥0.3mm plating) |
prevents oxidation, lowers contact resistance |
|
Contact resistance |
≤0.05mΩ per joint |
joint drop dominates string losses |
|
Tightening torque |
per terminal type (table above) |
loose overheats, over-tight cracks |
|
Corrosion protection |
conductive paste or heat-shrink |
mandatory in salt / acid mist |
§18c. Safety and Compliance — Hazard Classification and Prohibitions
LiFePO4 has good thermal stability, but high voltage, high current and thermal runaway still require strict installation and operating rules:
|
Level |
Meaning |
Typical situation |
|---|---|---|
|
DANGER |
Misuse can cause injury or death |
sealed enclosure (gas accumulation), non-dedicated charger, metal tool across terminals |
|
WARNING |
May cause injury or equipment damage |
uninsulated metal case, sparks or open flame, reversed polarity |
|
CAUTION |
May cause minor injury or damage |
outside the specified temperature, near heat sources, immersion or damp, direct sunlight |
Prohibitions:
|
Prohibition |
Requirement |
Reason |
|---|---|---|
|
Oxidising agents |
keep away from strong oxidisers |
listed as incompatible in the MSDS |
|
Mixing chemistries |
never series/parallel with lead-acid, NiMH or NMC |
different charge voltages and thresholds cause over-charge, leakage, fire |
|
Organic solvents |
no thinner, petrol, alcohol cleaning |
corrodes the case, causes cracking and leakage |
|
Exceeding rated current |
never above the datasheet maximum |
over-current heats, swells and damages the BMS |
|
Lifting by terminals |
never carry the pack by terminals or cables |
damages the internal group and seal |
|
Stepping / heavy loads |
do not step on or stack heavy items |
case deformation, internal short circuit |
|
Disassembly |
do not open the case or replace the BMS |
high voltage and electrolyte risk, warranty void |
Restricted applications (high-reliability):
|
Application |
Requirement |
Note |
|---|---|---|
|
Life-support medical |
requires an independent backup system |
battery failure can endanger life |
|
Dialysis equipment |
not recommended |
high-reliability requirement, professional assessment |
|
Nuclear / defence |
prohibited |
requires a dedicated non-commercial scheme |
|
Automotive / aviation / rail / marine control |
prohibited (auxiliary power excepted) |
moving-platform vibration and failure consequences |
|
Subsea equipment |
prohibited |
high pressure and humidity, leakage consequences |
Work protection and disposal:
|
Item |
Requirement |
Note |
|---|---|---|
|
Insulated tools |
tape-wrapped wrench, one terminal at a time |
prevents bridging the terminals |
|
PPE |
insulating gloves, goggles, insulated boots |
shock, burn and electrolyte splash |
|
Electrolyte contact |
flush skin or eyes with plenty of water for at least 15 minutes and seek medical help |
LiPF6 hydrolyses to HF, corrosive |
|
Scrap disposal |
return to a licensed recycler; never dismantle, incinerate or dump in water |
lithium, iron, copper and aluminium are recoverable |
Emergency handling:
|
Symptom |
Immediate action |
Note |
|---|---|---|
|
Swelling / deformation |
stop use and isolate |
precursor to thermal runaway |
|
Leakage / odour |
power off, ventilate, evacuate |
corrosive electrolyte plus flammable gas |
|
Abnormal heat |
stop charging, disconnect load |
check charger and wiring for short or reverse connection |
|
Abnormal cell voltage |
balance the string, handle the weak cell separately |
>50mV deviation needs matching |
|
Fire |
cool with copious cold water, or smother with dry powder, sand or earth; never use Halon |
burning evolves CO, CO2, HF and phosphorus fluorides |
This section follows mainstream LiFePO4 industrial safety practice for export project compliance review; site procedures, local regulations (e.g. NFPA 70E, IEC 62485) and contract terms take precedence. For life-safety applications have the design reviewed by a licensed electrical engineer.
§19. CHISEN Product Strength and Global Service System
Why choose CHISEN:
1. Product range: 20+ years in battery R&D and manufacturing, covering VRLA lead-acid, LiFePO4 modules, BMS and energy storage systems; ST / LT / BL / LB series across 12V / 24V / 36V / 48V, 7Ah to 300Ah, mainstream models in stock, bulk lead time typically 7-15 days subject to order confirmation.
2. Global service network: 60+ export countries (China / Southeast Asia / Europe / Africa / Middle East / Latin America / Central Asia / Oceania) with telecom, power, data centre, PV, RV-marine and medical project experience; multilingual technical documents and support (EN / CN / ES / FR / AR / RU).
3. Quality control: voltage and internal resistance checked on every unit before shipment, capacity and appearance sampled per batch; SPC on key processes (cell grading, BMS test, assembly, sealing); third-party inspection can be arranged.
4. Export support: CE declaration of conformity and first-hand customs documents (invoice / packing list / CO / MSDS / UN38.3 / sea-transport identification / factory test report); multilingual technical documents (EN / CN / ES / FR / AR / RU); destination approvals handled on request.
5. Long-term cooperation: dedicated technical contact for long-term customers; OEM partners can share sales leads and training; rebates, priority supply and new-product trials are set out in the agreement.
6. Sustainability: LiFePO4 is recyclable for lithium, iron, copper and aluminium; RoHS / REACH related declarations per test results; destination environmental and market-access requirements handled per customer need.
§20. Contact — Reply within 1 Business Day
CHISEN — 20+ years focused on batteries, exporting to 60+ countries.
Email: sales@chisen.cn (quotation and sizing proposal within one business day)
Tel / WhatsApp: +86 131 6622 6999
Website: https://www.chisen.cn
Location: production base: Guangdong province (LiFePO4 modules and BMS assembly); sales and technical support: Hangzhou, Zhejiang.
Note: figures on this page are taken from the current datasheet for selection reference. Specifications may change without notice; the contract and the datasheet shipped with the goods prevail. Certificates, test reports and destination approvals are provided per model.