CHISEN SPF12V150-ST 12.8V 150Ah LiFePO4 Battery | Lead-Acid Replacement / Maintenance-Free | OEM Factory Direct
30-Second Overview of CHISEN SPF12V150-ST
Model: SPF12V150-ST (12.8V 150Ah / 1920Wh, 4 LiFePO4 cells in series)
Technology: LiFePO4 cells + integrated BMS (over-charge / over-discharge / over-current / short circuit / temperature protection) + ABS case (IP65) + copper-core terminals
Highlights: ≥2000 cycles @80% DoD (4-6× lead-acid); 21kg pack, about 40% of the lead-acid weight; maintenance-free; up to 4 in series for a 48V system
Typical use: RV house battery, Marine power and lighting, Residential off-grid solar, Monitoring / CCTV backup
§1. Product Definition and Four Core Advantages
CHISEN SPF12V150-ST is a 12.8V 150Ah (1920Wh) LiFePO4 battery with 4 cells in series and an integrated BMS, packaged in a 8D case with the same footprint and terminal positions as the equivalent lead-acid / AGM / GEL battery, so the battery bay, hold-down and wiring need no change.
The ST series fits both motive and storage duty — electric vehicles, energy storage systems, defense and security, telecom outdoor, renewable energy and other harsh environments. For storage, size the capacity by backup time and daily energy; for motive duty, by continuous / peak current and range.
Configuration: 4S × 3.2V = 12.8V, 150Ah, 1920Wh; the BMS does cell-voltage sensing, passive balancing (balance point 14.4V) and over-charge / over-discharge / over-current / short-circuit / high-low temperature protection, with common charge-discharge port.
Charge / discharge: recommended CC/CV with 14.6V (4×3.65V) and 30A (0.2C), 100A maximum; max continuous discharge 150A (1.00C), peak 300A (3s), BMS cut-off 10V (4×2.5V).
Applications: RV house battery, Marine power and lighting, Residential off-grid solar, Monitoring / CCTV backup, Off-grid micro-grid.
CHISEN has focused on batteries for 20+ years, exporting to 60+ countries and supplying OEM/ODM customers in telecom, power, data centre, PV, RV/marine and medical-equipment sectors with cell, BMS and pack-level solutions.
Four core advantages:
1. 2000 deep cycles, about 4-6× lead-acid by cycle count: at one 80% DoD cycle per day, 2000 cycles is 5+ years of design life; lead-acid at the same duty (50% DoD, 300-500 cycles) needs a full replacement after 1 to 1.5 years. LiFePO4 does not sulphate when deep-discharged, so capacity fades gradually instead of dropping abruptly.
2. Lightweight: 21kg per pack against ~48kg for the same lead-acid capacity, about 56% lighter — easier handling, less ballast in the boat, more payload for AGVs and golf carts.
3. Maintenance-free, no water, no acid mist: sealed maintenance-free construction: no watering, no equalise charge, no acid mist and no sulphation; IP65 case, side mounting allowed (terminals forward) for tight RV, locker and cabinet spaces.
4. Five-fold BMS protection: over-charge cut at 15.6V, over-discharge cut at 10V, 450A over-current and short-circuit protection (250-500μs), 65℃ high-temperature cut-off and no charging below 0℃; the BMS disconnects and auto-recovers, preventing swelling and thermal runaway.
Also: round-trip efficiency ≥95% (typical) versus 70-85% for lead-acid, self-discharge <3%/month and 6+ months of shelf life at full charge, so the same PV array and charger put about 10-20% more energy into the battery.
§2. Key Specifications
Quick-reference specification for this model (full standards list in §4, series table in §6, charge and protection thresholds in §12 and §15).
|
Parameter |
Value |
|---|---|
|
Model |
SPF12V150-ST |
|
Series |
ST Standard Type |
|
Nominal voltage |
12.8V |
|
Nominal capacity |
150Ah (10-hour rate) |
|
Energy |
1920Wh |
|
Cell configuration |
LiFePO4, 4 cells in series |
|
Case / terminal style |
8D case |
|
Max continuous discharge |
150A (1.00C) |
|
Peak discharge current |
300A (3s) |
|
BMS discharge cut-off current |
450A ±20A (31ms) |
|
Recommended charge voltage |
14.6V (4×3.65V) |
|
Float / standby voltage |
13.8V (4×3.45V) |
|
BMS over-charge protection |
15.6V (4×3.9V) |
|
Balancing voltage |
14.4V (4×3.6V) |
|
Recommended charge current |
30A (0.2C) |
|
Max charge current |
100A (0.67C) |
|
Discharge cut-off voltage |
10V (4×2.5V) |
|
Recommended low-voltage disconnect |
11V (4×2.75V) |
|
Internal resistance (1kHz, 50% SOC, 25℃) |
≤8mΩ |
|
Dimensions L×W×H |
520×268×228 mm |
|
Weight |
21kg (±2%) |
|
Terminal |
T11 |
|
Terminal torque |
9-11 N·m |
|
Case material |
ABS engineering plastic |
|
Enclosure protection |
IP65 |
|
Self-discharge |
<3% / month (25℃) |
|
Cycle life |
≥2000 cycles @80% DoD (25℃) |
|
Charge temperature |
0 to 45℃ |
|
Discharge temperature |
−20 to 60℃ |
|
Storage temperature |
−5 to 35℃ |
|
Certification & documents |
CE declaration of conformity (DoC) and UN38.3 test summary supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; MSDS and sea-transport identification report included |
|
Shipping classification |
UN 3480, Class 9 |
Note: values above are taken from the datasheet for this model; dimensions are L×W×H including terminals, tolerance ±2mm.
§3. Model Nomenclature — Field Breakdown
CHISEN ST series uses a segmented code (series + voltage class + capacity + type + case), so a model can be selected from the system voltage and the available space alone.
|
Field |
Meaning |
This model |
|---|---|---|
|
SPF |
Product series |
SPF = LiFePO4 battery module |
|
12.8V |
Voltage class |
12.8V = 4 cells × 3.2V |
|
150 |
Rated capacity |
150Ah at the 10-hour rate |
|
-ST |
Product type |
ST = Standard Type (also LT low-temperature, BL Bluetooth, LB low-temp Bluetooth) |
|
8D case |
Case / terminal variant |
8D case |
SPF12V150-ST = SPF series + 12.8V class (4S) + 150Ah + ST standard type, 8D case.
§4. Applicable International / Regional / Chinese Standards
The standards below are referenced for design, procurement and tender documentation.
|
Standard |
Title |
Type |
Adoption |
Use |
|---|---|---|---|---|
|
IEC 62619:2022 |
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for secondary lithium cells and batteries for industrial applications |
International |
Safety design basis |
Export / industrial ESS |
|
IEC 62133-2:2017 |
Secondary sealed cells and batteries — Safety requirements for portable lithium systems |
International |
Cell and pack safety |
Export / customer acceptance |
|
UN38.3 |
UN Manual of Tests and Criteria, section 38.3 — transport safety testing |
International |
Transport testing |
Air / sea / courier |
|
UL 1642 |
Standard for safety — Lithium batteries (cells) |
USA |
Cell safety |
North America |
|
GB 31241-2022 |
Lithium-ion cells and batteries for portable electronic equipment — safety technical specification |
China |
Design reference |
Domestic sales / tenders |
|
GB 40165-2021 |
Lithium-ion cells and batteries for stationary electronic equipment — safety technical specification |
China |
Design reference |
Domestic ESS / tenders |
|
UN 3480 Class 9 |
UN Model Regulations — lithium-ion batteries (standalone) |
International |
Transport classification |
Booking / customs |
Note: third-party test reports and destination approvals (e.g. EU Battery Regulation, UL 2054 pack certification) are handled per project; standards are listed for design and procurement reference.
§5. Physical Construction and Materials (LiFePO4 cells + BMS)
Construction of CHISEN SPF12V150-ST:
Cells: prismatic aluminium-shell or cylindrical steel-shell LiFePO4 cells; the olivine LiFePO4 cathode is structurally stable and does not release oxygen, which is the root of the safety margin.
Anode and electrolyte: graphite anode with LiPF6 organic electrolyte and a polyethylene (PE) separator; cells are graded for capacity, voltage and internal resistance, matching within 20mV per group.
BMS: over-charge, over-discharge, over-current, short-circuit, high/low temperature protection and passive balancing, common port; cell sensing ±25mV, balancing starts at 14.4V and closes within 20mV.
five-fold protection thresholds (per 4 cells in series):
|
Protection |
Trigger |
Recovery |
Action time |
|---|---|---|---|
|
Over-charge |
cell ≥3.9V (pack 15.6V) |
auto-recover when back to 3.6V/cell (14.4V) |
instant |
|
Over-discharge |
cell ≤2.5V (pack 10V) |
recover after charging above 2.8V/cell |
instant |
|
Over-current |
≥450A ±20A |
auto-recover after load removal |
31ms |
|
Short circuit |
output shorted |
auto-recover after fault cleared |
250-500μs |
|
High temperature |
≥65℃ |
recover below 55℃ |
instant |
|
Low temperature |
charging ≤0℃ |
recover above 5℃ |
instant |
Case and sealing: ABS engineering plastic, 8D case, IP65; double sealing between case and lid (structural adhesive + gasket) and an O-ring at the terminal keep moisture out.
Marking: model and capacity are silk-screened or laser-marked on the front, with model, voltage, capacity, energy, production batch and warning marks.
Structural difference vs lead-acid: lead-acid (AGM / GEL) delivers 300-500 cycles to 80% capacity at 50% DoD and still needs equalise charging and terminal inspection; LiFePO4 delivers 2000+ cycles at 80% DoD with no maintenance. In the same space the usable energy is about 1.6× (80% vs 50% DoD), which is the direct value of lead-acid replacement.
Replacement warning: a lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, while this model needs 14.6V constant voltage. Keeping the lead-acid charger leaves the pack permanently under-charged, which fades capacity and defeats balancing — switch the charger to lithium mode or replace it (see §12).
§6. ST Series 12.8V Full Capacity Table (20 models)
The 12.8V platform of the ST series has 20 capacity models (LiFePO4, 4S). Models in the same voltage class are drop-in interchangeable by capacity and can be connected in series for higher system voltages.
|
No. |
Model |
V |
Ah |
Max A |
Size mm |
kg |
Terminal |
Case / BCI |
|---|---|---|---|---|---|---|---|---|
|
1 |
SPF12V7.2-ST |
12.8 |
7.2 |
15 |
151×65×102 |
0.9 |
F2 |
F2 small case |
|
2 |
SPF12V9-ST |
12.8 |
9 |
15 |
151×65×102 |
1.1 |
F2 |
F2 small case |
|
3 |
SPF12V10-ST |
12.8 |
10 |
15 |
151×98×105 |
1.3 |
F2 |
F2 small case |
|
4 |
SPF12V12-ST |
12.8 |
12 |
15 |
151×98×105 |
1.65 |
F2 |
F2 small case |
|
5 |
SPF12V20-ST |
12.8 |
20 |
20 |
181×76×168 |
2.6 |
NB1 |
NB1 case |
|
6 |
SPF12V35-ST |
12.8 |
35 |
35 |
195×131×171 |
4.4 |
T11 |
U1 case |
|
7 |
SPF12V40-ST |
12.8 |
40 |
40 |
198×166×171 |
5.4 |
T11 |
166 standard case |
|
8 |
SPF12V50-ST |
12.8 |
50 |
50 |
198×166×171 |
6.3 |
T11 |
166 standard case |
|
9 |
SPF12V75-ST |
12.8 |
75 |
75 |
260×168×221 |
9.6 |
T11 |
24 group case |
|
10 |
SPF12V80-ST |
12.8 |
80 |
80 |
307×168×221 |
10.4 |
T11 |
27 group case |
|
11 |
SPF12V100-ST-G27 |
12.8 |
100 |
100 |
307×168×221 |
12.2 |
T11 |
BCI 27 group |
|
12 |
SPF12V100-ST-G31 |
12.8 |
100 |
100 |
329×172×223 |
12.6 |
T11 |
BCI 31 group |
|
13 |
SPF12V100-DST-S |
12.8 |
100 |
100 |
318×175×190 |
12.6 |
DIN |
DIN short case (94R / H7L4 BCI) |
|
14 |
SPF12V100-DST |
12.8 |
100 |
100 |
355×175×190 |
12.8 |
DIN |
DIN long case (49 / H8L5 BCI) |
|
15 |
SPF12V125-ST |
12.8 |
125 |
150 |
329×172×223 |
14 |
T11 |
31 group case |
|
16 |
SPF12V150-ST |
12.8 |
150 |
150 |
520×268×228 |
21 |
T11 |
8D case |
|
17 |
SPF12V200-ST |
12.8 |
200 |
150 |
484×170×241 |
25.2 |
T11 |
compact case |
|
18 |
SPF12V200-ST-8D |
12.8 |
200 |
150 |
520×268×228 |
24.5 |
T11 |
8D case |
|
19 |
SPF12V260-ST |
12.8 |
260 |
150 |
520×268×228 |
30.5 |
T11 |
8D case |
|
20 |
SPF12V300-ST |
12.8 |
300 |
150 |
520×268×228 |
33.5 |
T11 |
8D case |
This page covers SPF12V150-ST, highlighted above: 150Ah / 1920Wh / 21kg.
Other voltage classes in the same series:
|
Class |
Series |
Models |
Capacity range |
Max discharge |
Typical use |
|---|---|---|---|---|---|
|
12V |
4S |
20 |
7.2-300Ah |
15-150A |
RV, marine, off-grid solar, telecom/CCTV, mobility and scrubbers |
|
24V |
8S |
9 |
10-140Ah |
15-140A |
AGV, wheelchairs, marine, RV, solar street lights |
|
36V |
12S |
6 |
7-96Ah |
10-100A |
Golf carts, tricycles, scrubbers, stackers, garden machinery |
|
48V |
16S |
5 |
12-72Ah |
20-72A |
Telecom sites, home ESS, golf carts, forklifts, edge data centres |
Note: do not mix capacities or batches in one string — every unit in a string must be the same model, capacity and batch (see §18b).
§7. Main Applications and Reference Cases
CHISEN SPF12V150-ST serves the following 5 applications (this model: 150Ah / 1920Wh, about 1536Wh usable at 80% DoD):
RV house battery: Replaces a lead-acid house battery of the same footprint, 80% DoD usable.
Marine power and lighting: Start plus house duty; still cranks after deep discharge.
Residential off-grid solar: Daily PV charge and night discharge for homes.
Monitoring / CCTV backup: 12V backup for small sites, cameras and access control; compact enough for a cabinet.
Off-grid micro-grid: Small island, pastoral and remote-site systems.
Every figure below is derived from this model's own capacity (DoD 0.8, inverter 0.9):
Case 1: Lighting / monitoring (sized from this model)
150Ah (1920Wh) drives a 230W load for about 6 hours at DoD 0.8 and 0.9 inverter efficiency; at 115W the runtime doubles to about 12 hours.
Case 2: Monitoring / telecom backup (sized from this model)
for a 4-hour backup the same pack supports 345W (1920Wh × 0.8 × 0.9 ÷ 4).
Case 3: Daily cycling (sized from this model)
one 80% DoD cycle per day gives 1536Wh per day, about 560640Wh per year; 2000 cycles is roughly 5 years.
Case 4: Lead-acid replacement (sized from this model)
the same lead-acid capacity offers about 960Wh usable (50% DoD) against 1536Wh here (80% DoD), 60% more energy, at 21kg versus about 48kg — about 56% lighter.
Case 5: String expansion (sized from this model)
4 in series gives a 51.2V / 7680Wh pack at 150Ah; up to 4 parallel strings, maximum 600Ah / 30720Wh.
§8. ST Series vs Lead-Acid / AGM / GEL — Full Comparison
Same footprint and nominal voltage, LiFePO4 against lead-acid (AGM / GEL):
|
Item |
This series (LiFePO4 ST) |
Lead-acid AGM / GEL |
Conclusion |
|---|---|---|---|
|
Energy density |
~91 Wh/kg |
~30-40 Wh/kg |
2-3× the energy per kg |
|
Cycle life |
≥2000 @80% DoD |
300-500 @50% DoD |
4-6× lead-acid |
|
Usable capacity |
80-90% DoD |
50% DoD (deeper cycles shorten life) |
60% more usable energy |
|
Round-trip efficiency |
≥95% |
70-85% |
10-20% more from the same PV array |
|
Self-discharge |
<3% / month |
3-5% / month, plus sulphation |
6+ months of shelf life |
|
Weight |
21kg |
~48kg |
about 56% lighter |
|
Maintenance |
none |
watering, equalise charge, corrosion checks |
near-zero O&M |
|
Continuous rate |
1.00C (peak 2.0C) |
0.2-0.3C |
no sag on starts |
|
Low-temperature discharge |
~65% at −20℃ (typical) |
~50% at −20℃ |
better for cold stores and winter |
|
Mounting |
any orientation except inverted |
upright only |
fits lockers and cabinets |
|
Environment |
no lead-acid electrolyte, fully recyclable |
lead and sulphuric acid, higher disposal requirements |
simpler recycling |
|
Replacements in 10 years |
1-2 |
4-6 |
lower total cost of ownership |
§9. Selection Decision Table
Fit of this model (150Ah / 12.8V) in each application; "suitable in combination" means several units in series or parallel are needed.
|
Application |
Fit for this model |
Note |
|---|---|---|
|
Monitoring / lighting / access control |
Suitable |
150Ah is enough |
|
RV / camper house power |
Suitable |
75Ah and above recommended; this model is 150Ah |
|
Marine power / house |
Suitable |
≥1C for starting; 100Ah and above |
|
Residential off-grid solar |
Suitable |
size from night consumption ÷ 0.8 DoD |
|
Telecom / CCTV backup |
Suitable |
4-10 hour backup |
|
Telecom site 48V |
Suitable in combination |
direct at 48V; string other classes |
|
Golf cart / e-tricycle |
Suitable in combination |
direct at 36V / 48V; 3-4 in series from 12V |
|
AGV / forklift |
Suitable in combination |
direct at 24V / 48V; string other classes |
§10. Capacity Sizing Formula and Configuration Examples
Capacity (Ah) = load (W) × backup time (h) ÷ system voltage (V) ÷ inverter efficiency ÷ depth of discharge ÷ temperature factor
Assumptions: inverter efficiency 0.85 (low-frequency) / 0.90 (high-frequency) / 1.0 (DC loads).
DoD and temperature: LiFePO4 allows 0.80-0.90 (lead-acid only 0.50); temperature factor 1.0 at 25℃, 0.90 at 0℃, 0.75 at −10℃, 0.65 at −20℃, 0.95 at 45℃; keep 20-30% ageing margin.
Sizing example 1 (12.8V system): off-grid lighting load 200W for 8h per day, inverter 0.9, DoD 0.8 → 200×8÷12.8÷0.9÷0.8 ≈ 173.6Ah — select 150Ah × 2 in parallel (300Ah total).
Pack example 2 (4 in series = 51.2V / 7680Wh pack): at DoD 0.8 and inverter 0.9 it supports 1400W for about 3.9 hours (7680×0.8×0.9÷1400); at 700W the runtime doubles to about 7.9 hours.
constant-current discharge capability (25℃, typical, varies with temperature and load):
|
Discharge time |
Current |
Usable capacity |
Power at 12.8V |
|---|---|---|---|
|
20 HR |
7.5 A |
150 Ah |
~96 W |
|
10 HR |
15.0 A |
150 Ah |
~192 W |
|
5 HR |
30.0 A |
150 Ah |
~384 W |
|
3 HR |
50.0 A |
147 Ah |
~627 W |
|
1 HR |
150.0 A |
142 Ah |
~1824 W |
Rule of thumb: short high-current duty (UPS 30min class) needs a high-rate model, checked against the current table in §15; long low-current duty (telecom 4-10h) uses the 10HR row.
charger compatibility is where lead-acid replacements most often go wrong:
|
Charger type |
Directly usable? |
Setting |
|---|---|---|
|
Lithium charger |
Directly usable |
14.6V constant voltage, current ≤30A (0.2C) |
|
Existing lead-acid charger |
Not directly |
Switch to lithium mode (14.6V CV) or replace; temperature compensation must be off |
|
MPPT solar controller |
Must support lithium |
Absorption 14.6V, float 13.8V; disable lead-acid equalise and temp compensation |
|
Vehicle DC-DC / alternator |
Must limit voltage |
Output must not exceed 15.6V or the BMS over-charge protection trips |
|
Inverter-charger |
Usable |
Select LiFePO4 / 4S mode, charge current 0.2C |
§11. Cycle Life and Total Cost of Ownership (TCO)
Cycle life is ≥2000 cycles @80% DoD (25℃); cells still hold above 80% capacity after 2000 cycles at 1C charge/discharge, and a pack cycled at the usual 0.2C typically exceeds the rating.
TCO = purchase cost + replacements × purchase cost + maintenance + downtime loss − residual value
|
Item |
LiFePO4 (this series) |
Lead-acid AGM / GEL |
|---|---|---|
|
Cycle life |
2000 @80% DoD |
350 @50% DoD |
|
10-year cycles (one per day) |
3650 |
3650 |
|
Packs needed over 10 years |
2 |
11 |
|
Purchase cost index (example) |
1.0 |
0.45 per pack |
|
10-year purchase index |
2.0 |
4.9 |
|
Maintenance |
none |
watering, equalise, corrosion checks |
|
Downtime replacements |
1 |
10 |
|
Cost per cycle |
low |
high |
Note: the cost index is an illustrative assumption used only to show the replacement-count difference; request a quotation for actual project pricing.
§12. Charge Voltage Setting and Temperature Relationship
Standard charge is 14.6V (4×3.65V) CC/CV at 30A (0.2C), 100A maximum; float / standby is 13.8V (4×3.45V).
|
Stage |
Voltage (25℃) |
Current |
Termination |
|---|---|---|---|
|
Constant current (CC) |
raise to 14.6V |
30A (0.2C) |
reaches 14.6V |
|
Constant voltage (CV) |
14.6V |
tapering |
current falls to 0.05C (~7.5A) |
|
Float / standby |
13.8V |
≤0.02C |
continuous |
|
Balancing |
14.4V |
passive |
cell delta <20mV |
Charging strategy by temperature:
|
Temperature |
Allowed current |
Charge voltage |
Note |
|---|---|---|---|
|
< 0℃ |
charging prohibited |
— |
BMS blocks the charge path; cold stores and winter sites need heating or the LT version |
|
0-10℃ |
0.1C limit |
14.6V |
low-temperature charge acceptance is reduced |
|
10-25℃ |
0.2C |
14.6V |
optimum window |
|
25-40℃ |
0.2-0.3C |
14.6V |
ensure ventilation |
|
40-45℃ |
0.1C derated |
14.6V |
no charging above 45℃ |
|
> 45℃ |
charging prohibited |
— |
BMS high-temperature protection |
LiFePO4 does not need the lead-acid (-3mV/℃/cell) temperature compensation; the BMS handles the cell thresholds, so the charger only has to hold the CV point accurately.
Replacement point: this is the step where lead-acid replacements fail most often. A lead-acid charger floats at 13.6-13.8V and equalises at 14.4V, both below what this model needs, so the pack is permanently under-charged, cells drift apart and capacity fades quickly. Set the charger to 14.6V CV with 0.2C current limit, or replace it with a lithium charger; disable any temperature compensation.
§13. Operating Temperature Range (discharge / charge / storage)
Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; optimum 25℃ (the capacity reference point). The BMS cuts at 65℃ and recovers at 55℃.
|
Temperature |
Usable capacity (typical) |
Charging |
Note |
|---|---|---|---|
|
60℃ (discharge limit) |
~95% |
prohibited |
derated; forced ventilation required |
|
40℃ |
~100% |
0.1C derated |
avoid direct sunlight, improve cooling |
|
25℃ (reference) |
100% |
0.2C |
best balance of capacity and life |
|
0℃ |
~90% |
0.1C limit |
lower charge acceptance |
|
−10℃ |
~75% |
prohibited |
pre-heat above 0℃ before charging |
|
−20℃ (discharge limit) |
~65% |
prohibited |
discharge only, BMS low-temperature protection |
Note: capacity varies with rate and temperature; figures are typical at 0.2C. At −20℃ LiFePO4 still delivers about 65% while lead-acid delivers about 50%, which matters for cold stores and high-altitude projects.
heat accelerates ageing: above 25℃ every 10℃ rise roughly halves cycle life, so for continuous duty above 45℃ improve ventilation, lower the charge voltage ceiling or select a high-temperature derated option.
§14. Self-Discharge Rate and Storage Conditions
Self-discharge is below 3%/month at 25℃ from full charge, so a fully charged pack still starts after 6 months; for long storage keep 30-50% SOC and top up every 3 months.
|
Storage temperature |
Self-discharge |
Recharge interval |
Remaining capacity |
|---|---|---|---|
|
20℃ |
<1.5% / month |
12 months |
~90% |
|
25℃ |
<3% / month |
6 months |
~85% |
|
35℃ |
<4% / month |
3 months |
~80% |
|
45℃ |
<6% / month |
1-2 months |
~70% |
Store between −5 and 35℃ in a dry, ventilated place, away from sunlight, solvents and corrosive gases; insulate the terminals, never store loose with metal parts; discharge to 30-50% SOC before long storage and top up every 3 months. Packs stored more than 12 months need a full charge/discharge and a capacity check before commissioning.
§15. Maximum Charge Current and Discharge Cut-off Voltage
Recommended charge 30A (0.2C), maximum 100A (0.67C); maximum continuous discharge 150A (1.00C), peak 300A (3s), BMS over-current and short-circuit protection 450A ±20A (31ms).
|
Discharge current |
Cut-off voltage |
Typical use |
|---|---|---|
|
≤ 0.1C (≤ 15.0A) |
10V |
long-term standby, monitoring |
|
0.1-0.5C (15.0-75.0A) |
10V |
normal cycling |
|
0.5-1.0C (75.0-150.0A) |
10V |
traction, starting, inverter peaks |
|
1.0-2.0C (150.0-300.0A) |
10V |
short peaks (≤3s), BMS limited |
|
> 2.0C (> 300.0A) |
— |
prohibited; BMS over-current trips |
Short-circuit protection: the BMS opens within 250-500μs; from the 1kHz AC internal resistance of 8mΩ the prospective short-circuit current is about 1600A (12.8V÷8mΩ), quoted only for fuse and cable sizing, not a test value.
End-of-charge: the pack is full when the CV current falls below 0.05C (about 7.5A); after termination the BMS keeps monitoring and restarts charging when a cell falls below 3.6V/cell.
§16. OEM/ODM One-Stop Customization
CHISEN SPF12V150-ST supports one-stop OEM/ODM without changing the standard electrical performance:
Case colour: ABS case in customer Pantone (standard grey-white plus red / blue / green / yellow / orange or any custom colour).
Printing and marking: customer logo silk-screen (any language), laser marking of model / serial / production date / customer code / barcode.
Packaging: standard colour box plus neutral carton; custom logo, colour, barcode and security label.
Label: battery label laid out to customer requirement, multi-language and multi-regulation.
Terminal: standard T11; other terminal forms can be tooled per project.
BMS options: optional RS485 / CAN, Bluetooth app monitoring, low-temperature heating film, dual output.
Certification and documents: CE declaration of conformity (DoC), UN38.3 test summary, MSDS and sea-transport identification supplied with each shipment; UL 1642 and IEC 62133-2 on customer request; third-party inspection per project.
MOQ and lead time: samples from 1 unit; stock models 7-15 days, custom 30-45 days; container MOQ depends on model and packaging.
for a customised proposal and quotation, email sales@chisen.cn with model, quantity, destination market and certification requirements; reply within one business day.
§17. FAQ — High-Frequency Engineering Questions
The 18 questions industrial site engineers ask most, covering parameters, selection, installation, charging equipment, shipping and after-sales.
1. What are the charge voltage and current for SPF12V150-ST?
14.6V (4×3.65V) with 30A recommended (0.2C) and 100A maximum; float / standby 13.8V (4×3.45V); BMS over-charge cut-off 15.6V.
2. What is the cycle life?
≥2000 cycles @80% DoD at 25℃; one deep cycle per day gives 5+ years of design life, and shallower cycling (50% DoD) goes well beyond 2000 cycles.
3. Can it replace lead-acid directly?
Yes. Footprint, terminal positions and nominal voltage match, so the bay and wiring stay as they are; but the lead-acid charger must be set to 14.6V constant voltage with 0.2C limit, otherwise permanent under-charging fades the pack quickly (see §12).
4. Can it be connected in series or parallel?
the datasheet allows up to 4 in series (12.8V→51.2V); parallel up to 4 units, parallel before series. Before connecting, cell delta must be <50mV and internal resistance deviation <15%, and all units must share model, capacity and batch.
5. Can it be charged below 0℃?
No — the BMS blocks charging below 0℃ (it can still discharge, about 65% of capacity at −20℃). For cold stores and winter sites select the LT low-temperature version or add a heating film.
6. What are the internal resistance and short-circuit current?
Internal resistance ≤8mΩ at 1kHz, 50% SOC, 25℃; the prospective short-circuit current is about 1600A estimated from that resistance, quoted for fuse sizing only, not a test value.
7. What are the terminal, dimensions and weight?
T11, torque 9-11 N·m; 520×268×228 mm; 21kg.
8. What about operating temperature and self-discharge?
Discharge −20 to 60℃, charge 0 to 45℃, storage −5 to 35℃; self-discharge <3%/month at 25℃ and 6 months of shelf life from full charge.
9. Which standards does it meet?
IEC 62619:2022, IEC 62133-2, UN38.3 and UL 1642 (cells), designed with reference to GB 31241-2022 and GB 40165-2021. A CE declaration of conformity (DoC) and the UN38.3 test summary are supplied with every shipment; UL 1642 and IEC 62133-2 are arranged on request; shipment follows UN 3480 Class 9.
10. Can it be side-mounted or inverted?
Upright or side-mounted (terminals forward) with a maximum 90° tilt; never inverted — the seal and internal cell group do not allow it.
11. Which documents are needed for export?
Packing list, commercial invoice, CO, MSDS, UN38.3 test summary and the sea-transport identification report (UN3480, Class 9 dangerous goods, under the IMDG Code; packing group as stated on the dangerous-goods certificate); third-party inspection and destination approvals on request.
12. What are the MOQ and lead time?
Samples from 1 unit; stock models 7-15 days, OEM customisation 30-45 days; container MOQ depends on model and packaging.
13. What is the warranty?
24 months from shipment, or 2000 cycles @80% DoD / ≥80% capacity retention, whichever comes first; extended terms are negotiable and warranty letters can be issued for tenders.
14. How are price and freight quoted?
EXW factory price; sea freight quoted to destination port (FOB / CIF / DDP). Email sales@chisen.cn with quantity, destination port and certification requirements.
15. Can it be charged directly from a solar controller?
The MPPT controller must support lithium: absorption 14.6V, float 13.8V, with lead-acid equalise and temperature compensation disabled. Controllers without a lithium mode will under-charge the pack.
16. Do I need an external balancer?
No. The BMS balances passively at 14.4V (3.6V per cell); a full charge is needed periodically to trigger balancing — long periods of partial charging let cell delta grow.
17. Can old and new batteries be mixed?
No. A used unit has higher internal resistance and will be repeatedly over-charged and over-discharged in the string; replace the whole string with the same model, capacity and batch.
18. What causes a swollen battery?
Typically over-charging from a non-dedicated charger, long-term high temperature, internal short circuit or a failed BMS. Swelling is irreversible — stop using it and scrap it, never charge or discharge it again.
§18. Daily Operation and Maintenance (Engineering Guide)
Follow these seven points and SPF12V150-ST will hold 5+ years at 25℃ with one 80% DoD cycle per day:
1. Charger selection: use an industrial charger with CV/CC and temperature protection, CV point 14.6V, current limit 0.2C (30A); never use a lead-acid fast charger or connect straight to an alternator.
2. Installation environment: install in a cabinet or rack, ≥200mm above the floor (damp) and ≥100mm from walls (heat dissipation); ambient −20 to 60℃, no direct sun or heat source; forced ventilation in enclosed spaces.
3. Routine inspection: monthly check terminal torque (9-11 N·m) and oxidation; quarterly check cell delta (<50mV) and appearance (swelling / leakage / cracks); annual capacity check.
4. Long-term storage: discharge to 30-50% SOC, store at −5 to 35℃ dry, top up every 3 months; packs stored over 12 months need a full charge/discharge before use.
5. Troubleshooting: capacity down >20%: check the CV point and cell balance; abnormal voltage (off 12.8V by ±1.5V): top up or replace that unit; swelling / leakage / odour: stop use and isolate; frequent BMS trips: check wiring and load.
6. First use: on receipt measure open-circuit voltage (12.8-13.4V) and internal resistance after 2h rest; fully charge once before commissioning and balance strings (cell delta <20mV).
7. Safety prohibitions: never bridge both terminals with a metal tool (hundreds of amps, burns); no open flame near charging; wear goggles and insulating gloves; return scrap batteries to a licensed recycler — never dismantle, incinerate or dump.
§18b. Installation Requirements — Mandatory Delivery Checks
LiFePO4 is maintenance-free, but spacing, torque, environment and string matching directly affect safety and life. These are the mandatory delivery checks:
|
Item |
Requirement |
Note |
|---|---|---|
|
Orientation |
Upright or side-mounted (terminals forward), max 90° tilt |
Never inverted — the seal and cell group do not allow it |
|
Position |
Accessible for inspection and replacement |
Lowest level, to see swelling and leakage early |
|
Spacing between units |
≥10mm natural convection, do not stack tight |
≥15mm inside cabinets for heat dissipation |
|
Distance from heat sources |
≥50cm |
Avoid boiler, transformer and switchgear heat |
|
Distance from wall / floor |
≥100mm / ≥200mm |
Bottom ventilation, damp protection |
|
Rack load |
21kg per unit; rack ≥3× total weight |
Reinforce shelves in multi-tier racks |
|
Terminal torque |
9-11 N·m |
Loose joints overheat; over-torque cracks the post |
|
Enclosure protection |
IP65 (do not immerse) |
Add a rain cover outdoors |
Terminal tightening torque by terminal type:
|
Terminal type |
Torque |
Applicable models |
|---|---|---|
|
F2 push-in |
tool-free, push fully home |
7.2Ah / 10Ah small models |
|
NB1 (M6 bolt) |
4-5 N·m |
20Ah and below (12V / 24V / 36V small models) |
|
T11 / M8 bolt |
9-11 N·m |
35-300Ah main models |
|
DIN terminal (M8) |
9-11 N·m |
100Ah DIN short / long case |
Environmental requirements:
|
Item |
Allowed range |
Note |
|---|---|---|
|
Ambient temperature |
discharge −20 to 60℃; charge 0 to 45℃ |
outside the range performance and life degrade |
|
Enclosed space |
not in a fully sealed cabinet |
gas accumulation during charge risks swelling |
|
Relative humidity |
≤85% RH non-condensing |
high humidity corrodes terminals |
|
Altitude |
≤3000m without derating |
above 3000m derate 8% per 1000m |
|
Dust / corrosive gas |
avoid salt mist, acid mist, ammonia |
use a protective cabinet or coating |
|
Vibration |
avoid continuous vibration (>2g) |
add damping pads on vehicles and boats |
String rules (critical):
Matching: cell delta <50mV and internal resistance deviation <15% within a string.
Same batch: same model, same capacity, same batch; mixing batches causes over-charge / over-discharge of the weakest cell (weakest-cell effect).
Series / parallel: the datasheet allows up to 4 in series (12.8V→51.2V); parallel up to 4 units, parallel before series.
Cables: size the cable for the continuous current (1C = 150A, 1.5× margin); short-circuit current is only for fuse selection, not cable sizing.
Wiring order: follow positive first, then negative; parallel before series; never reverse the polarity (a 25.6V difference will destroy the BMS instantly).
Before commissioning: fully charge the string for 4-8 hours to balance before commissioning and record every cell voltage.
|
Item |
Specification |
Engineering note |
|---|---|---|
|
Connector material |
tin-plated copper (≥0.3mm plating) |
prevents oxidation, lowers contact resistance |
|
Contact resistance |
≤0.05mΩ per joint |
joint drop dominates string losses |
|
Tightening torque |
per terminal type (table above) |
loose overheats, over-tight cracks |
|
Corrosion protection |
conductive paste or heat-shrink |
mandatory in salt / acid mist |
§18c. Safety and Compliance — Hazard Classification and Prohibitions
LiFePO4 has good thermal stability, but high voltage, high current and thermal runaway still require strict installation and operating rules:
|
Level |
Meaning |
Typical situation |
|---|---|---|
|
DANGER |
Misuse can cause injury or death |
sealed enclosure (gas accumulation), non-dedicated charger, metal tool across terminals |
|
WARNING |
May cause injury or equipment damage |
uninsulated metal case, sparks or open flame, reversed polarity |
|
CAUTION |
May cause minor injury or damage |
outside the specified temperature, near heat sources, immersion or damp, direct sunlight |
Prohibitions:
|
Prohibition |
Requirement |
Reason |
|---|---|---|
|
Oxidising agents |
keep away from strong oxidisers |
listed as incompatible in the MSDS |
|
Mixing chemistries |
never series/parallel with lead-acid, NiMH or NMC |
different charge voltages and thresholds cause over-charge, leakage, fire |
|
Organic solvents |
no thinner, petrol, alcohol cleaning |
corrodes the case, causes cracking and leakage |
|
Exceeding rated current |
never above the datasheet maximum |
over-current heats, swells and damages the BMS |
|
Lifting by terminals |
never carry the pack by terminals or cables |
damages the internal group and seal |
|
Stepping / heavy loads |
do not step on or stack heavy items |
case deformation, internal short circuit |
|
Disassembly |
do not open the case or replace the BMS |
high voltage and electrolyte risk, warranty void |
Restricted applications (high-reliability):
|
Application |
Requirement |
Note |
|---|---|---|
|
Life-support medical |
requires an independent backup system |
battery failure can endanger life |
|
Dialysis equipment |
not recommended |
high-reliability requirement, professional assessment |
|
Nuclear / defence |
prohibited |
requires a dedicated non-commercial scheme |
|
Automotive / aviation / rail / marine control |
prohibited (auxiliary power excepted) |
moving-platform vibration and failure consequences |
|
Subsea equipment |
prohibited |
high pressure and humidity, leakage consequences |
Work protection and disposal:
|
Item |
Requirement |
Note |
|---|---|---|
|
Insulated tools |
tape-wrapped wrench, one terminal at a time |
prevents bridging the terminals |
|
PPE |
insulating gloves, goggles, insulated boots |
shock, burn and electrolyte splash |
|
Electrolyte contact |
flush skin or eyes with plenty of water for at least 15 minutes and seek medical help |
LiPF6 hydrolyses to HF, corrosive |
|
Scrap disposal |
return to a licensed recycler; never dismantle, incinerate or dump in water |
lithium, iron, copper and aluminium are recoverable |
Emergency handling:
|
Symptom |
Immediate action |
Note |
|---|---|---|
|
Swelling / deformation |
stop use and isolate |
precursor to thermal runaway |
|
Leakage / odour |
power off, ventilate, evacuate |
corrosive electrolyte plus flammable gas |
|
Abnormal heat |
stop charging, disconnect load |
check charger and wiring for short or reverse connection |
|
Abnormal cell voltage |
balance the string, handle the weak cell separately |
>50mV deviation needs matching |
|
Fire |
cool with copious cold water, or smother with dry powder, sand or earth; never use Halon |
burning evolves CO, CO2, HF and phosphorus fluorides |
This section follows mainstream LiFePO4 industrial safety practice for export project compliance review; site procedures, local regulations (e.g. NFPA 70E, IEC 62485) and contract terms take precedence. For life-safety applications have the design reviewed by a licensed electrical engineer.
§19. CHISEN Product Strength and Global Service System
Why choose CHISEN:
1. Product range: 20+ years in battery R&D and manufacturing, covering VRLA lead-acid, LiFePO4 modules, BMS and energy storage systems; ST / LT / BL / LB series across 12V / 24V / 36V / 48V, 7Ah to 300Ah, mainstream models in stock, bulk lead time typically 7-15 days subject to order confirmation.
2. Global service network: 60+ export countries (China / Southeast Asia / Europe / Africa / Middle East / Latin America / Central Asia / Oceania) with telecom, power, data centre, PV, RV-marine and medical project experience; multilingual technical documents and support (EN / CN / ES / FR / AR / RU).
3. Quality control: voltage and internal resistance checked on every unit before shipment, capacity and appearance sampled per batch; SPC on key processes (cell grading, BMS test, assembly, sealing); third-party inspection can be arranged.
4. Export support: CE declaration of conformity and first-hand customs documents (invoice / packing list / CO / MSDS / UN38.3 / sea-transport identification / factory test report); multilingual technical documents (EN / CN / ES / FR / AR / RU); destination approvals handled on request.
5. Long-term cooperation: dedicated technical contact for long-term customers; OEM partners can share sales leads and training; rebates, priority supply and new-product trials are set out in the agreement.
6. Sustainability: LiFePO4 is recyclable for lithium, iron, copper and aluminium; RoHS / REACH related declarations per test results; destination environmental and market-access requirements handled per customer need.
§20. Contact — Reply within 1 Business Day
CHISEN — 20+ years focused on batteries, exporting to 60+ countries.
Email: sales@chisen.cn (quotation and sizing proposal within one business day)
Tel / WhatsApp: +86 131 6622 6999
Website: https://www.chisen.cn
Location: production base: Guangdong province (LiFePO4 modules and BMS assembly); sales and technical support: Hangzhou, Zhejiang.
Note: figures on this page are taken from the current datasheet for selection reference. Specifications may change without notice; the contract and the datasheet shipped with the goods prevail. Certificates, test reports and destination approvals are provided per model.