CHISEN 6-QTF-105 (DIN LN6/H9): 12V 105Ah (1260Wh) AGM start-stop battery, 950A CCA, 190 min RC, 28.2 kg, 392×174×190 mm. Drop-in for the same EFB/AGM battery; maintenance-free, heat- and vibration-resistant.
产品详情

CHISEN 6-QTF-105 (LN6/H9) 12V 105Ah Start-Stop Battery
Start-Stop Duty / Maintenance-Free | OEM Factory Direct

6-QTF Series · AGM VRLA · 12V Start-Stop · DIN H9 (LN6) · CCA 950A · GB/T 43346-2023 / 5008.1-2023 / 5008.2-2023

30-second overview of CHISEN 6-QTF-105

Model: 6-QTF-105 (12V 105Ah / 1260Wh, DIN size LN6 / H9)

Technology: AGM VRLA, Pb-Ca-Sn gravity-cast grid, ultra-fine glass-mat separator (starved electrolyte). Maintenance-free, no free acid, side-mount capable; engineered for frequent cranking and regenerative braking (micro-hybrid / 12V mild-hybrid) duty.

Key capabilities: CCA 950A (-18°C, 30s, ≥7.2V) | reserve capacity 190 min | acceptable charge current 0-210A | self-discharge<8% / 90 days @25°C | operating temperature -30°C to 70°C

Fitment: L x W x H 392×174×190 mm (including terminals), 28.2 kg, 44.7 Wh/kg; case and terminal layout follow the LN6 group, so it drops into the same tray as the original EFB / AGM start-stop battery without changing the clamp or wiring.

Typical applications: Start-stop passenger cars, SUVs / MPVs, ride-hailing and taxi fleets (high cranking counts), refrigerated and converted vehicles as an auxiliary battery; 12V start-stop vehicles with regenerative braking.

CHISEN 6-QTF-105 is a 12V AGM start-stop battery with a 20-hour rating of 105Ah (1260Wh) and a cold cranking current of 950A, DIN size LN6 (H9), 392×174×190 mm and 28.2 kg. It combines starter-battery high-rate discharge with deep-cycle endurance: gravity-cast Pb-Ca-Sn grids, a 4BS-seeded positive paste and a carbon-enhanced negative paste, separated by an ultra-fine glass mat in a starved-electrolyte design. That combination is what keeps capacity stable when the battery is cycled repeatedly at 60-80% state of charge (PSOC) — the harshest duty a start-stop system can impose.

A start-stop system shuts the engine down at traffic lights, in congestion or while waiting, then restarts it instantly — 200 to 400 cranks a day is normal. Vehicles with regenerative braking also push 13.5-14.8V pulse current back into the battery on overrun. Under this shallow-cycle, high-current regime a flooded battery sulphates and loses water quickly and may drop below usable capacity within a year. An AGM start-stop battery holds the electrolyte in the glass mat, recombines oxygen efficiently and accepts charge fast, which is why its service life under the same duty is several times longer — and why start-stop vehicles must use AGM or EFB, never a conventional battery.

Four core advantages:

1. Built for start-stop duty: grid alloy and paste formulation are tuned for PSOC cycling; the carbon additive in the negative plate suppresses sulphation and the 4BS seed in the positive plate raises active-material utilisation and recovery after deep discharge.

2. High charge acceptance: 0-210A acceptable charge current lets the battery absorb regenerative braking pulses instead of boiling dry or bulging the way a flooded battery would.

3. Reliable cold cranking: 950A CCA per GB/T 5008.1-2023 (-18°C, 30s, ≥7.2V); operating range -30°C to 70°C. Low internal resistance keeps voltage sag small and the engine still cranks at -30°C.

4. Maintenance-free, heat- and vibration-resistant: the starved AGM design has no free acid and never needs topping up; the PP case withstands engine-bay heat; the glass mat clamps the plates firmly, so vibration resistance is far better than a flooded battery.

Note: specifications in this page follow the applicable standard and the factory inspection record for this model. CCA per GB/T 5008.1-2023 (-18°C, 30s, ≥7.2V); reserve capacity is the minutes at 25°C at 25A down to 10.5V.

▎ §2 CHISEN 6-QTF-105 Key Specifications

Quick-selection data for this model (full series in §6, charging and cut-off thresholds in §12 and §15, installation requirements in §18b).

Model

6-QTF-105

DIN size

LN6 (H9)

Nominal voltage

12V (6 cells x 2V)

Rated capacity (20h, 25°C)

105Ah (1260Wh)

Reserve capacity (25°C, 25A to 10.5V)

190 min

CCA (-18°C, 30s, ≥7.2V)

950 A

Overall dimensions (L x W x H)

392×174×190 mm (tolerance ±2mm)

Weight (reference)

28.2 kg

Terminal type

Tapered post (positive Φ19.5₋₀.₃ / negative Φ17.9₋₀.₃, taper 1:9) (polarity R)

Plates per cell

21 plates / cell

Case material

High-temperature resistant polypropylene (PP)

Self-discharge (25°C)

<8% / 90 days @25°C

Operating temperature

-30°C to 70°C

Charging voltage (25°C)

13.5V-14.8V @25°C

Acceptable charge current

0-210 A

Standards

GB/T 43346-2023 / GB/T 5008.1-2023 / GB/T 5008.2-2023

System

12V start-stop (micro-hybrid) with regenerative braking

Note: 20h rate current is about 5.25A (capacity / 20); 1h rate current about 105A; the CCA-to-capacity ratio of 9.05 A/Ah indicates the high-rate cranking capability of this model.

▎ §3 CHISEN 6-QTF-105 Model Designation

A start-stop part number encodes cell count, purpose, construction, capacity, DIN size and CCA — enough to confirm voltage, capacity, dimensions and cranking capability without a cross-reference table.

6-QTF-105 = 6 cells (12V) + Q cranking duty + T start-stop specific + F valve-regulated (AGM) + 105 for the 20h capacity + LN6 for the DIN size + 950A in brackets for cold cranking current.

Field

Meaning

This model

6

Number of cells

12V system (2V per cell)

Q

Cranking duty (start, ignition, lighting)

High-rate discharge design

T

Start-stop (Start-Stop) specific

Deep-cycle and charge-acceptance optimised

F

Valve-regulated (VRLA / AGM)

Maintenance-free, no free acid

105

20h rated capacity

This model: 105Ah

LN6

DIN case size (L x W x H)

This model: 392×174×190 mm

(950)

Cold cranking current

This model: CCA 950A

Note: letters are interpreted slightly differently between makers (6-QW and 6-QTP also appear). Always select on DIN size + capacity + CCA; the letters only indicate construction.

▎ §4 CHISEN 6-QTF-105 Applicable International / Regional / Chinese Standards

This model is designed and factory-tested against the standards below. Actual conformity is evidenced by the third-party test report and the customer approval sheet for the model; the standard numbers can be quoted directly in purchasing, customs classification and tender documents.

Standard

Title

Type

Status

Use

GB/T 43346-2023

Lead-acid batteries for start-stop — Technical conditions

China national

Applied

Start-stop cycling, charge acceptance, factory inspection

GB/T 5008.1-2023

Lead-acid starter batteries — Part 1: Technical conditions and methods of test

China national

Applied

Classification, requirements, test methods, inspection rules

GB/T 5008.2-2023

Lead-acid starter batteries — Part 2: Product varieties and specifications

China national

Applied

Varieties, dimensions (DIN/BCI cross-reference)

EN 50342-1

Lead-acid starter batteries — General requirements and methods of test

EU

Benchmarked

Reserve capacity, cycle endurance, vibration (CCA criterion differs from GB/T 5008.1)

VDA start-stop specification (AGM)

German automotive industry start-stop battery specification

Industry spec

Benchmarked

German OEM acceptance criteria

JB/T 12666-2016

Lead-acid batteries for start-stop

China industry

Referenced

Start-stop cycling and charge acceptance tests

GB/T 5008.1-2013 / 5008.2-2013

Lead-acid starter batteries (2013)

China national

Marked

Short form GB/T 5008-2013 on nameplate; superseded 2024-06-01

Note: the 2013 edition exists as two parts (GB/T 5008.1-2013 / 5008.2-2013) and appears in short form on the nameplate; the 2023 editions apply to factory testing. Standard numbers are for design reference, purchasing and tender documents; third-party test reports and destination-market approval (e.g. EU Battery Regulation 2023/1542, BCI registration in North America) are handled per project.

▎ §5 CHISEN 6-QTF-105 Construction and Materials

Construction and materials of CHISEN 6-QTF-105:

Grid: Pb-Ca-Sn gravity-cast grid, high tin, antimony-free. The high hydrogen over-potential suppresses gassing at the end of charge and cuts water loss; removing antimony also removes the water-loss / thermal-runaway chain of lead-antimony alloys and the premature capacity loss (PCL) that lead-calcium alloys can suffer.

Paste: The positive paste is seeded with 4BS (tetrabasic lead sulphate) crystals to raise active-material utilisation and recovery after deep discharge. The negative paste uses a carbon (carbon black / activated carbon) formulation that suppresses negative-plate sulphation — the dominant failure mode in start-stop duty — and improves charge acceptance.

Separator: Ultra-fine glass-mat (AGM) separator with high porosity and low resistance holds the electrolyte between the plates (starved design) and applies compression to the plate stack — the key to vibration resistance and to the oxygen-recombination path.

Case: High-temperature polypropylene (PP) case with through-partition wall welding, resistant to engine-bay heat, oil and cleaning agents. The lid is heat-sealed to the case and the low-pressure rubber valve vents only under abnormal over-pressure, so water loss in normal service is negligible.

Terminals and valve: Tapered T2 posts (SAE 1:9 taper), positive Φ19.5₋₀.₃ mm and negative Φ17.9₋₀.₃ mm, polarity R (positive on the right), cast from lead-tin alloy so the vehicle clamp seats directly; a seal ring at the post root prevents acid creep and corrosion.

Component

Material / construction

Function

Positive grid

Pb-Ca-Sn alloy (high tin, no antimony)

Corrosion resistance, low gassing, less water loss

Positive paste

4BS seed + conductive additive

Active-material utilisation and deep-discharge recovery

Negative paste

Carbon (carbon black / activated carbon)

Suppresses PSOC sulphation, raises charge acceptance

Separator

Ultra-fine glass mat (AGM)

Holds electrolyte, resists vibration, oxygen path

Electrolyte

Dilute sulphuric acid, starved (absorbed)

No free acid; side-mount, maintenance-free

Case / lid

High-temperature PP, wall weld + heat seal

Engine-bay heat, vibration, sealing

Terminals

Lead-tin tapered post (1:9)

Direct SAE clamp fit, low contact resistance

Safety valve

Low-pressure rubber valve

Vents on over-pressure, sealed in normal use

Structure vs. flooded: A flooded battery keeps free liquid electrolyte around the plates; deep discharge and repeated high currents cause stratification, water loss and active-material shedding. AGM locks the electrolyte in the glass mat, runs starved and applies high stack pressure, so the plates stay intact under vibration and deep cycling. For the same volume the AGM design typically delivers three to four times the cycle life of a flooded battery — the reason start-stop vehicles require AGM.

Replacement note: No tray or harness change is needed to fit a start-stop battery, but confirm the vehicle charging window (13.5-14.8V) and that the alternator and energy-recovery strategy match AGM. An EFB-equipped vehicle without regeneration can be upgraded to AGM (more durable); downgrading an AGM vehicle to EFB is not recommended.

▎ §6 CHISEN 6-QTF-105 6-QTF Series 12V Start-Stop (7 Models · DIN LN0-LN6)

CHISEN 6-QTF 12V start-stop AGM series covers 7 capacities, DIN sizes LN0 to LN6, 40 to 105Ah and CCA 460 to 950A. Within the same voltage class the model follows capacity and tray size directly — no rewiring.

The highlighted row is this page's model 6-QTF-105: 105Ah / CCA 950A / 28.2 kg / 392×174×190 mm.

No.

Model

DIN

Capacity

CCA

Reserve

Dimensions mm

Weight

1

6-QTF-40

LN0

40Ah

460A

90 min

175×174×190

12.4 kg

2

6-QTF-50

LN1

50Ah

570A

100 min

207×174×190

14.3 kg

3

6-QTF-60

LN2

60Ah

660A

100 min

243×174×190

17.1 kg

4

6-QTF-70

LN3

70Ah

720A

120 min

276×174×190

19.8 kg

5

6-QTF-80

LN4

80Ah

800A

140 min

314×174×190

22.5 kg

6

6-QTF-92

LN5

92Ah

850A

160 min

352×174×190

25.2 kg

7

6-QTF-105

LN6

105Ah

950A

190 min

392×174×190

28.2 kg

Note: do not mix capacities or batches in one bank; dual-battery vehicles must use the same model, batch and capacity. Dimension tolerance ±2mm, weight tolerance ±3%.

▎ §7 CHISEN 6-QTF-105 Applications and Vehicle Fitment

CHISEN 6-QTF-105 serves the five application groups below (105Ah / CCA 950A / reserve capacity 190 min):

Start-stop cars with regenerative braking: Engine off at lights and in congestion, instant restart, energy recovery on overrun; charge acceptance and PSOC life are decisive.

Ride-hailing, taxi and short-trip fleets: Hundreds of cranks a day with shallow cycling; a conventional battery fades within 1-1.5 years, an AGM fades far more slowly.

SUV / MPV / commercial vehicles: Heavy electrical loads (power sliding doors, seat heating, rear climate) alongside start-stop; needs more capacity and higher CCA.

Refrigerated and converted vehicles: Parking cooling, vehicle fridges, inverters; the AGM deep-cycle capability suits auxiliary-battery duty.

Marine and RV 12V cranking / auxiliary: High vibration and frequent cycling; AGM resists vibration, needs no maintenance and cannot spill acid.

General fitment by DIN size (always confirm the actual tray dimensions, CCA requirement and vehicle configuration):

DIN size

Capacity

Typical vehicle class

Typical engine / configuration

LN0

40Ah

A0 / mini and small hatchbacks

1.0-1.4L, basic start-stop

LN1

50Ah

Compact sedans / hatchbacks

1.0-1.6L, start-stop + regeneration

LN2

60Ah

Compact / mid-size sedans

1.4-1.8L, start-stop + regeneration

LN3

70Ah

Mid-size sedans / compact SUVs

1.6-2.0L, high cranking counts

LN4

80Ah

Mid-size / large sedans and SUVs

1.8-2.5L, heavy electrical load

LN5

92Ah

Large sedans / large SUVs

2.0-3.0L, common in premium brands

LN6

105Ah

Large sedans / MPV / big SUVs

Above 2.5L, dual-battery vehicles

Note: fitment is a general mapping. Tray length/width/height, terminal polarity (left/right) and the hold-down must be checked on the vehicle; different model years of the same car may use different sizes depending on equipment.

▎ §8 CHISEN 6-QTF-105 AGM vs. EFB vs. Flooded

For the same installation space and nominal voltage, the key differences between the three battery types are summarised below for customer Q&A and tender comparisons:

Item

AGM (this series)

EFB

Flooded

Conclusion

Construction

AGM, starved, glass mat

EFB, flooded + enhanced separator

Flooded

AGM: vibration-proof, no free acid

Start-stop cycle life

Excellent

Moderate

Poor (fades within 1-1.5 years)

AGM 3-4x a flooded battery

Charge acceptance

High, 0-210A

Moderate

Low

Energy recovery demands high acceptance

Deep-discharge recovery

Good

Fair

Poor (sulphates)

AGM suits shallow cycling

Water loss / service

Maintenance-free, minimal loss

Maintenance-free, higher loss

Topping-up needed

AGM is maintenance-free

Heat resistance

Good (engine bay)

Moderate

Moderate

PP case + starved design

Vibration resistance

Excellent (compressed stack)

Moderate

Poor

Suits rough roads

Application

Start-stop with regeneration

Entry start-stop, no regeneration

Non-start-stop vehicles

Select by vehicle configuration

Note: EFB and AGM must not be downgraded into each other. Fitting EFB to an AGM vehicle causes rapid failure because charging voltage and regeneration current do not match; EFB vehicles can be upgraded to AGM.

▎ §9 CHISEN 6-QTF-105 Selection Matrix

Check the dimensions first, then capacity and CCA. This model measures 392×174×190 mm (L x W x overall H, including terminals), DIN size LN6: if any of the three exceeds the original battery tray (or leaves the hold-down loose), it will not fit — always measure the tray and terminal layout on the vehicle.

The table judges this model (105Ah / CCA 950A / LN6) against each application. "Usable (multiple units)" means a dual-battery or parallel arrangement is required.

Application / condition

Suitability

Comment

Dimensions differ from the original tray

Not usable

The 392×174×190 dimensions must match the removed battery (including terminals), or it will not fit and the clamp will not seat

Terminal polarity does not match

Not usable

The harness will not reach and the clamp will not fit; check polarity (this model: R)

Compact / mid-size sedan start-stop

First choice

Capacity and CCA match; drop-in once dimensions fit

SUV / MPV with heavy loads

Usable

Select LN4 and above against the vehicle CCA requirement

Ride-hailing / taxi, high cranking

First choice

PSOC cycle life is the decisive metric

Parking cooling / inverter use

Usable

Frequent deep discharge; consider a dual-battery setup

Large vehicles / dual-battery

Combination

Use LN6 for the second battery position

Severe cold (-30°C)

Usable

CCA is rated at -18°C; verify -30°C margin against the vehicle

Note: for export selection, lock the model on DIN size (LN6) + capacity + CCA. Different capacities within one DIN class may share a case, but adjacent classes do not (LN3 is 38 mm shorter than LN4) — never select on capacity alone.

▎ §10 CHISEN 6-QTF-105 Sizing: CCA Requirement and Capacity Calculation

Select on CCA first, then capacity and dimensions. OEMs publish a minimum CCA based on displacement, compression ratio and climate; for aftermarket replacement the new battery must never be below the vehicle's rated CCA.

Engine displacement

Minimum CCA (reference)

Model

Typical vehicle

1.0-1.4L petrol

300-400A

LN0 / LN1

Small cars, A0 class

1.4-1.8L petrol

400-550A

LN1 / LN2

Compact and mid-size sedans

1.8-2.5L petrol

550-700A

LN3 / LN4

Mid-size sedans, SUVs

2.5-3.5L petrol / light diesel

700-850A

LN4 / LN5

Large and premium vehicles

Above 3.5L / large diesel

850A and above

LN5 / LN6

Large SUV, MPV, dual battery

Note: CCA requirements vary with compression ratio, fuel type and climate; in -30°C regions add 20% to the minimum when selecting.

For auxiliary power (second battery / refrigeration / RV) size on usable energy:

Usable energy (Wh) = nominal capacity (Ah) x 12V x depth of discharge (DoD) x temperature factor

This model: 105Ah (1260Wh). At the 50% DoD usually chosen for AGM, usable energy is about 630Wh; at 80% DoD about 1008Wh (deep discharge shortens cycle life — keep at or below 50%).

Load

Daily consumption (12V)

Runtime on this model

Comment

12V fridge (45W)

0.39A x 24h ≈ 9.4Ah/day

About 5 days

DoD 50%, 25°C

Parking cooler (500W inverter)

About 46Ah/day

About 1 day

Use dual battery or larger capacity

LED lighting + phone charging (60W)

About 5.6Ah/day

About 9 days

Typical camping duty

Dashcam parking mode (5W)

About 0.5Ah/day

About 100 days

Use low-voltage protection

▎ §11 CHISEN 6-QTF-105 Cycle Life and Total Cost of Ownership

Start-stop battery life is counted in cranks and cycle depth, not years. The AGM glass mat applies high stack pressure and, together with the carbon negative paste, slows negative-plate sulphation far below a flooded battery when cycling at 60-80% state of charge; under equal duty the cycle life is typically three to four times longer.

TCO = purchase price x replacements + downtime + maintenance cost - salvage value

Type

Cost index

Typical life in start-stop duty

5-year cost of ownership

Flooded

1.0 (baseline)

About 1.0-1.5 years (start-stop duty)

3-4 replacements in 5 years

EFB

1.3

About 2.5-3.0 years

1-2 replacements in 5 years

AGM (this series)

1.8

About 4.0-5.0 years

0-1 replacements in 5 years

Note: cost index and life figures are illustrative assumptions used to explain the difference in replacement counts; they are not quotations. Real life depends strongly on the vehicle charging strategy, ambient temperature and daily cranking count.

▎ §12 CHISEN 6-QTF-105 Charging System Match (critical when replacing)

The charging window of this model is 13.5V-14.8V @25°C, controlled by the alternator and the energy-recovery strategy. For external charging use constant voltage 14.4-14.8V at 25°C with current limited to 0.1-0.2C. AGM accepts charge quickly but also suffers most from prolonged over-voltage: holding above 15V accelerates water loss and grid corrosion.

Stage

Voltage (25°C)

Current

Termination

Constant current

-

0.1-0.2C (10.5-21A)

Until 14.4V reached

Constant voltage

14.4-14.8V (25°C)

Tapering

Current falls below 0.02C

Float / storage

13.5-13.8V

-

Continuous

Charging voltage by temperature (compensation about -3.9mV/°C per cell, i.e. about -23mV/°C for a 12V battery):

Temperature

Charging voltage

Comment

-30 to -10°C

15.0-15.3V

No high-current charging; warm up first

-10 to 0°C

14.8-15.0V

Limit to 0.1C

0-25°C

14.4-14.8V

Standard charging

25-40°C

14.1-14.4V

Lower the CV setpoint

40-60°C

13.8-14.1V

Improve ventilation, shorten CV stage

60-70°C

13.5-13.8V

Float only, no high-current charging

Replacement note: this is where battery replacement most often goes wrong. Start-stop charging strategy lives in the vehicle BCM/ECU, so after fitting, perform battery registration or adaptation with a diagnostic tool. Otherwise the new battery is charged against the old battery's internal resistance model and is chronically under- or over-charged. When upgrading an EFB vehicle to AGM, confirm the upper charging limit is at least 14.4V; downgrading AGM to EFB is not recommended.

▎ §13 CHISEN 6-QTF-105 Temperature Behaviour (capacity / cranking / life)

Operating temperature -30°C to 70°C. Capacity and CCA vary with temperature; the table gives typical values normalised to 25°C = 100%.

Temperature

Usable capacity (typical)

CCA (typical)

Comment

-30°C

About 50%

About 45%

Harshest cold crank; keep CCA margin

-18°C

About 65%

About 70%

CCA reference temperature (to 7.2V, 30s)

0°C

About 85%

About 88%

Normal winter duty

25°C

100%

100%

Capacity and CCA reference

40°C

About 102%

About 100%

Slightly higher capacity, faster ageing

60°C

About 100%

About 95%

Engine-bay hot zone; improve cooling

70°C

About 95%

About 90%

Upper limit; avoid prolonged exposure

Low-temperature cranking: At -18°C the electrolyte viscosity rises and ion mobility drops, so both usable capacity and CCA fall. The thin glass mat and high porosity of AGM raise internal resistance less than a flooded battery, which is why it is more reliable in cold climates.

High-temperature life: Heat is the number one killer of AGM life: above 25°C every 10°C rise roughly halves cycle life (rule of thumb). Batteries in the engine bay sit at 60-70°C for long periods, so fit a heat shield, avoid sustained over-voltage charging and check the case for bulging.

Average temperature

Relative life

Comment

25°C

100% (baseline)

Standard duty

35°C

About 75%

Typical engine-bay temperature

45°C

About 50%

Heat shielding required

Above 55°C

Below about 30%

Not suitable for long-term use

▎ §14 CHISEN 6-QTF-105 Self-discharge and Storage

Self-discharge is<8% / 90 days @25°C, about half that of a flooded battery (lead-calcium alloy gasses less). A fully charged battery still cranks after 6 months in storage, but periodic boost charging is still required to prevent sulphation.

Storage temperature

Self-discharge

Boost interval

Comment

-10 to 10°C

<5% / 90 days

12 months

Best for long storage

10-25°C

<8% / 90 days

6 months

Normal warehouse conditions

25-35°C

About 10% / 90 days

3 months

Higher self-discharge

35-45°C

About 15% / 90 days

1-2 months

Not for long storage

Store in a cool, dry, well-ventilated warehouse away from sunlight and heat sources. Never stack upside down or more than two layers on their side. Fit insulating caps on the terminals and keep metal parts away to avoid short circuits. Charge fully before long storage and boost every 3-6 months to above 12.6V; batteries stored over 12 months should have a full charge and capacity check before commissioning.

▎ §15 CHISEN 6-QTF-105 Discharge Behaviour and Cut-off Voltage

This model: CCA 950A (-18°C, 30s, terminal voltage ≥7.2V; 10s ≥7.5V) and reserve capacity 190 min (25°C, 25A to 10.5V). The table gives recommended cut-off voltages by discharge current; discharging below cut-off causes irreversible sulphation.

Discharge current

Recommended cut-off

Typical use

0.05C (20h rate)

10.5V

Capacity rating (5.25A)

0.1C (10h rate)

10.5V

Telecom / lighting long discharges

0.2C (5h rate)

10.2V

Normal vehicle electrical loads

1C-3C

9.6V

Cranking transients (seconds)

CCA cold crank

≥7.2V (-18°C)

30s criterion (10s ≥7.5V)

Voltage sag during cranking is the most direct health indicator: below 9.0V at -18°C indicates significant CCA loss, and a rest voltage below 12.4V (about 50% state of charge) calls for immediate charging. If a conductance / internal-resistance tester reports CCA more than 20% below the rating, replacement is due.

▎ §16 CHISEN 6-QTF-105 OEM / ODM Customisation

CHISEN 6-QTF-105 supports one-stop OEM/ODM customisation; none of the options changes the standard electrical performance:

Item

Customisation options

Comment

Brand and printing

Customer logo, label in any language, laser marking (model/batch/date)

MOQ depends on model and packaging

Case colour

Standard black / dark grey; Pantone colour on request

Requires mould colour change, higher MOQ

Terminal layout

Tapered SAE 1:9 standard; positive/negative left-right swap possible

Confirm vehicle harness for swapped layout

Label content

Multi-language nameplate, warnings, CCA/RC marking, QR traceability

Typeset to destination regulations

Packaging

Colour box + neutral carton; pallet, shipping marks and barcodes

Container loading per §18b

Performance options

Capacity, CCA grade, low-water-loss or high-temperature formulation

Sample validation per project

Certification and documents

Third-party test reports, MSDS, CO, transport assessment

Reports and CO ship with the goods

MOQ and lead time

Samples from 1 pc; stock models 7-15 days; custom 30-45 days

FCL MOQ depends on model

For a customisation proposal and quotation, email sales@chisen.cn with model, quantity, target market and certification requirements; we reply within one business day.

▎ §17 CHISEN 6-QTF-105 FAQ (18 questions)

The 18 questions most often asked by OEMs, workshops and end users, covering specifications, selection, replacement, charging, installation and after-sales.

1. What is the CCA of 6-QTF-105 and how is it measured? Cold cranking current is 950A, measured at -18°C for 30s with terminal voltage ≥7.2V (10s ≥7.5V). In service a conductance-type CCA tester reads it directly; a reading more than 20% below the rating means replacement is due.

2. Can it replace a flooded battery? Yes, but only for vehicles that do not have start-stop. Start-stop vehicles must use AGM or EFB; a conventional battery fails within about a year in that duty.

3. The vehicle came with EFB — can I fit AGM? Yes, AGM is an upgrade (more durable, better charge acceptance). Perform battery registration afterwards. The reverse, AGM to EFB, is not recommended.

4. Can I go one capacity size up? This is the largest model in the series, so there is no size up. For dual-battery vehicles use a matched main/auxiliary pair; if a smaller unit is required, step down one size (105Ah to 92Ah).

5. Does it need topping up? No. AGM is valve-regulated and starved; water recombines in the oxygen cycle and normal service loses almost none. Never open the lid.

6. Can it be mounted on its side or upside down? Upright or on its side is fine (the AGM design has no free acid), but never upside down — the safety valve is designed for upright operation.

7. What charging voltage should be used? 13.5V-14.8V @25°C. For external charging use constant voltage 14.4-14.8V at 25°C with 0.1-0.2C current limit; holding above 15V accelerates water loss.

8. How long does a full charge take? At 0.1C (10.5A), roughly 10-12 hours from deep discharge. In normal start-stop duty the alternator keeps it topped up and no external charger is needed.

9. Does it crank in extreme cold? It cranks at -30°C; at -18°C about 70% of CCA remains. In very cold regions add 20% CCA margin and check terminals and ground straps.

10. What does heat do to it? Engine-bay temperatures of 60-70°C accelerate water loss and grid corrosion and roughly halve life. Use a heat shield and avoid sustained over-voltage charging.

11. Is self-discharge high? Self-discharge is<8% / 90 days @25°C, about half that of a flooded battery; a fully charged unit still cranks after 6 months.

12. What is the white powder on the terminals? Terminal corrosion (sulphate / oxide), usually from an aged seal ring or over-voltage charging. Clean it, apply terminal grease and check the charging voltage.

13. Why did the battery bulge? Over-charging, heat, a failed safety valve or an internal short. Bulging is irreversible — replace immediately and do not keep using it.

14. How do I replace batteries on a dual-battery vehicle? Replace main and auxiliary together with the same model, batch and capacity; replacing one only makes the old and new units over- and under-charge each other.

15. What is the warranty? Export orders are normally sold outright (as-is) with warranty terms set in the contract; a limited warranty can be negotiated per project (typically 12-18 months, manufacturing defects only, with batch number and test data). Over-charging, deep discharge, case damage and over-storage are excluded.

16. Which documents are needed for export? Lead-acid batteries ship under UN 2794 (class 8, electrolyte). MSDS, packing list, commercial invoice and CO accompany the goods; some destinations also require battery registration or recycling declarations.

17. How do I know the battery needs replacing? Weak or delayed cranking, rest voltage below 12.4V, CCA more than 20% below rating, or the start-stop function switching itself off (vehicle protection strategy).

18. Can old and new batteries be mixed? No. The old unit has higher internal resistance and drags the new one through repeated over- and under-charge; always replace the full set with the same model and batch.

▎ §18 CHISEN 6-QTF-105 Routine Maintenance and Operating Guide

Following these seven points keeps 6-QTF-105 in service beyond four years (25°C, up to 100 cranks a day, vehicle with energy recovery):

1. Charging system: check alternator output (13.5-14.8V) and registration status annually; always register the battery after replacement.

2. Terminals: check clamp force and corrosion every 6 months (5-7 N·m), clean and apply terminal grease; check the ground strap too.

3. Rest voltage: measure open-circuit voltage monthly — above 12.6V is healthy, 12.4V needs charging, below 12.2V calls for a parasitic-drain check.

4. Long parking: if the vehicle is unused for more than a month, disconnect the negative terminal or use a smart maintenance charger at 13.5V float; charge fully before reuse.

5. Heat protection: make sure the heat shield is intact, keep the battery away from the exhaust manifold and do not cut power immediately after a long hot run.

6. Vibration and clamping: the hold-down must be tight — a battery moving in its tray sheds active material.

7. Troubleshooting: weak cranking — test CCA and rest voltage; bulging — replace immediately; hot terminals — clean and tighten; start-stop disabled — check battery health before the vehicle strategy.

▎ §18b CHISEN 6-QTF-105 Installation Requirements — Delivery Checklist

AGM is maintenance-free, but mounting position, clamp torque, terminal fit and the vehicle charging strategy decide safety and life. These are the delivery and after-sales checkpoints:

Item

Requirement

Comment

Position

Original battery location, upright or on its side

Never upside down; keep away from the exhaust manifold

Hold-down

Original clamp / bracket tight, battery cannot move

Vibration sheds active material

Terminal fit

SAE tapered posts (positive Φ19.5 / negative Φ17.9)

Clamp must seat fully, not half-way

Terminal torque

Terminal clamp bolt 5-7 N·m

Over-tightening cracks the post seal

Venting

AGM does not vent in normal use but keep airflow around it

Avoid gas build-up in sealed boxes

Heat shielding

Fit a heat shield near heat sources

Above 60°C in the engine bay shortens life

Ground

Clean and tighten the body ground point

Poor ground causes abnormal charging voltage

Registration

Register the battery with a diagnostic tool

Mandatory on start-stop vehicles

Terminals and fasteners:

Location

Torque

Applies to

Tapered post (SAE 1:9)

5-7 N·m

All models in this series

Terminal clamp bolt

8-10 N·m

M6/M8 bolts, per clamp type

Hold-down bracket

8-12 N·m

Per vehicle manual

Packaging and loading (per container, confirmed per order):

Packaging

Quantity

Comment

Colour box + neutral carton

1 pc / box

Label per customer

Pallet

24-48 pcs / pallet by model

Stretch film + edge protectors

20GP container

About 900-1,100 pcs (mixed)

Calculated per model mix

40HQ container

About 2,100-2,400 pcs (mixed)

Heavy cargo — mind the weight limit

Note: lead-acid batteries ship under UN 2794 (class 8). Sea freight needs an MSDS and a transport assessment; air freight is generally not accepted — confirm with the carrier.

▎ §18c CHISEN 6-QTF-105 Safety and Compliance — Hazard Classes and Prohibitions

Lead-acid batteries contain dilute sulphuric acid and lead and are class 8 dangerous goods (UN 2794). AGM has no free acid and does not vent in normal use, so the risk is lower than a flooded battery, but short circuits, over-charging and heat still require strict control:

Hazard

Level

Consequence

Short circuit

Very high

A metal tool across the posts can draw thousands of amps — burns and explosion

Over-charging

High

Sustained charging above 15V gasses, dries and bulges the battery, up to thermal runaway

High temperature

Medium-high

Above 70°C ageing accelerates and the case softens

Mechanical damage

Medium

Cracked case leaks acid (starved AGM leaks little but is still corrosive)

Deep discharge

Medium

Stored below 10.5V for long causes irreversible sulphation

Prohibited: Never short the terminals, reverse the polarity, work with open flame or smoke nearby, weld or grind next to the battery, open the lid or add any liquid, drop or crush the battery, or dump scrap batteries into water or household waste.

Prohibited action

Requirement

Reason

Shorting the posts

Never

Huge current, burns / explosion

Reverse polarity

Never

Damages vehicle electronic modules

Open flame / smoking

Never

Vented gas can ignite

Opening the lid to add liquid

Never

Breaks sealing and the oxygen cycle

Upside-down / dropping

Never

Electrolyte leakage, plate damage

Mixing old and new

Not allowed

Mutual over- and under-charging

Non-dedicated charger

Not allowed

Voltage mismatch causes over-charging

Protective equipment and disposal: Wear goggles and acid-resistant gloves. If acid contacts skin, rinse with plenty of water for 15 minutes and seek medical help. Return scrap batteries to a licensed recycler and meet local obligations (e.g. EU Battery Regulation 2023/1542).

Emergency response: Acid in the eyes — rinse immediately and seek medical help. Battery bulging or smoking — stop charging, isolate and ventilate, use a dry-powder extinguisher and never spray water on live equipment. Battery damaged in a collision — disconnect the negative terminal, isolate it and hand it to a specialist.

This section follows common lead-acid safety practice and the relevant requirements of GB/T 43346-2023 and is provided for export compliance review; site rules, local regulations and contract terms take precedence.

Troubleshooting:

Symptom

Immediate action

Comment

Weak / slow cranking

Check rest voltage and CCA; charge or replace

Replace when CCA is below 80% of rating

Rest voltage falls quickly

Check parasitic drain and charging voltage

Leakage or alternator fault

Hot or corroded terminals

Clean, tighten, apply grease

Excessive contact resistance

Bulging case

Replace immediately, stop using

Over-charging or heat

Start-stop not working

Check battery health and vehicle strategy

Vehicle disables it at low SOC

Acid leakage / smell

Isolate, ventilate, handle professionally

Cracked case or failed valve

▎ §19 CHISEN 6-QTF-105 CHISEN Capability and Global Service

CHISEN capability and global service (why choose CHISEN):

1. Product range: founded in 2002, focused on battery R&D and manufacturing, covering lead-acid VRLA (AGM/GEL), automotive start-stop batteries, LiFePO4 modules and energy-storage systems. The start-stop range covers DIN LN0-LN6, 40-105Ah; mainstream models are stocked with 7-15 day lead times.

2. Manufacturing and quality: SPC control on gravity casting, paste mixing, wall welding, heat sealing and formation; every unit is voltage-, CCA- and appearance-checked before shipment, with batch sampling for capacity and leak testing; third-party inspection can be arranged.

3. Global service: exports to more than 60 countries (Southeast Asia, Europe, the Middle East, Africa, Latin America, Central Asia) with experience in passenger-car aftermarket, tier-2 OEM supply and parts chains; technical documents in EN/ES/FR/AR/RU/ZH.

4. Export support: MSDS, transport assessment report, CO, packing list and commercial invoice; destination battery registration, recycling declarations and label compliance on request.

5. Long-term partnership: a dedicated technical contact for key accounts; OEM customers share fitment data and training material; rebates, priority supply and new-product trials per agreement.

6. Sustainability: lead-acid is recycled at above 95%; scrap batteries close the loop for lead, plastics and electrolyte; RoHS / REACH declarations per test results.

▎ §20 CHISEN 6-QTF-105 Contact — reply within one business day

CHISEN — since 2002, focused on batteries, exporting to over 60 countries.

Contact:

Email: sales@chisen.cn (quotation and selection support, reply within one business day)

Phone / WhatsApp: +86 131 6622 6999

Website: https://www.chisen.cn

Note: specifications come from the current factory specification; they may change without notice and the contract and the shipped specification prevail.